Phencyclidine (PCP) One Step Test Kits with Ce ISO Approved

China Phencyclidine (PCP) One Step Test Kits with Ce ISO Approved, Find details about China Phencyclidine Pcp One Step Test, Medical Diagnostic Pcp Test Kits from Phencyclidine (PCP) One Step Test Kits with Ce ISO Approved

Model NO.
Phencyclidine
Certificate
Ce, ISO9001, ISO13485
Abbr.
Pcp
Storage
4-30ºC
Shelf Time
24months
Manufacturer
Independent R & D
Name
Medical Diagnostic Pcp Test Kits
Sensitivity
25ng/Ml
Specificity
99%
Reaction Time
5 Minutes
Trademark
OEM
Transport Package
as Required
Specification
strip/cassette
Origin
Henan, China
HS Code
38220090
Model NO.
Phencyclidine
Certificate
Ce, ISO9001, ISO13485
Abbr.
Pcp
Storage
4-30ºC
Shelf Time
24months
Manufacturer
Independent R & D
Name
Medical Diagnostic Pcp Test Kits
Sensitivity
25ng/Ml
Specificity
99%
Reaction Time
5 Minutes
Trademark
OEM
Transport Package
as Required
Specification
strip/cassette
Origin
Henan, China
HS Code
38220090
                         Phencyclidine (PCP)  One Step Test Kits With CE ISO Approved
 

Introduction:

Phencyclidine is a kind of drug that depress the central nervous system.It is used for therapeutic applications for hypnotics,anticonvulsants and sedatives.This drug is taken orally as capsules or tablets.The effects resemble those of alcohol intoxication.Repeated use of pcp can lead to tolerance and physical dependency. Once a popular drug of abuse,pcp use has declined in recent years,due to doctors not prescribing the drug as often.

 

Storage and Stability:

Kit can be stored at room temperature or refrigerated at 2-30°C.The test panel is stable through the expiration date printed on the sealed pouch.The test panel must remain in the sealed pouch until use.DO NOT FREEZE. Do not use beyond the expiration date.

 

Precaution:

  1. For healthcare professionals and professionals at point of care sites.
  2. For in vitro diagnostic use only.Do not use after the expiration date.
  3. The test panel should remain in the sealed pouch until use.
  4. All specimens should be considered potentially hazardous and handled in the same manner as an infectious agent.
  5. The used test panel should be discarded according to federal,state and local regulations

Procedure:

  1. collect a urine sample from test subject using a suitable clean container preferably glass.
  2. refregerated specimens or other materials should be equilibrated to room temperature before testing.
  3. open the foil pouch at the notch,remove the test device,and label the device with specimen ID
  4. holding the dropper vertically as shown,add 4 drop of urine into the sample well "S",waiting 5 seconds between drops
  5. observe migration,or lateral flow of the sample across the entire test panel.add additional sample drops if migration is not complete
  6. positive results may be observed as soon as 5 minutes,depending on the concentration of Opiates in the tested specimen.to confirm negative results, a complete reaction time of 8-10 minutes is required. do not interpret results after 15 minutes.

 

Detailed Images
Phencyclidine (PCP) One Step Test Kits with Ce ISO Approved

Phencyclidine (PCP) One Step Test Kits with Ce ISO ApprovedPhencyclidine (PCP) One Step Test Kits with Ce ISO Approved

 
Certifications
Phencyclidine (PCP) One Step Test Kits with Ce ISO Approved