China 60kV Transformer Primary Current and Secondary Current Tester, Find details about China primary current test, secondary current test from 60kV Transformer Primary Current and Secondary Current Tester
GDCT-9500B Wireless HV CT Turns Ratio Tester is designed for online measurement of high voltage CT, primary current , secondary current, turns ratio, polarity, leakage current of transformer 60kV and below (such as: 10kV or 35kV).
It can also be used as high-precision low-voltage clamp ammeter and leakage ammeter If the insulating rod is not used. It is integrated with functions of meter below: high/low voltage clip-on ammeter, high-altitude current telemeter, high-altitude leakage current tester, high precision clamp leakage ammeter.
It is composed of special high voltage tester, LV current clamp, main unit, HV insulating rod, monitoring software, communication line and so on, Wireless data transmission can penetrate wall barriers, linear transmission distance of 30 meters.
It is widely used in the substation, power plants, the auditing departments of electric power, industrial and mining enterprises as well as the testing station, electrical maintenance department and so on.
Function | Online test of current, ratio, polarity, phase difference and leakage current of the primary and secondary circuit of the HV & LV current transformer; On - line test of current and ratio on both sides of transformer |
Power supply | AC220V±10%, 50±1Hz; DC6V alkaline dry battery (1.5V AAA size 4pcs), can continuously work for 30 hours. |
Test method | Clip-on CT |
Transmission mode | Wireless transmission, linear transmission distance 30m |
Display | LCD: 128*64 dot matrix Backlight function, applicable in the darkness. |
LCD size | Display area: 44mm*27mm |
Meter size (Width*Height*Thickness) | Main unit: 78*165*42mm High voltage tester: 76*255*31mm LV current clamp: 70*115*38mm |
Size of clamp | High voltage tester: φ48mm LV current clamp: 25mm*30mm |
Sampling rate | 2 times/second |
Measurement range | High voltage tester: 0.0mA~1200A LV current clamp: 0.00mA~10A |
Resolution | High voltage tester: 0.01mA; LV current clamp: 0.01mA |
Gear shift | Fully automatic gear shift |
Accuracy of primary loop test (23ºC±3ºC, <80%RH) | 0.0mA~10.0A: ±1%±5dgt |
10.0A~49.9A: ±2%±5dgt | |
50.0A~199.9A: ±3%±5dgt | |
200A~600A: ±4%±5dgt | |
601A~1200A: ±5%±5dgt | |
Accuracy of secondary loop test | 0.00mA~10A: ±0.5%±5dgt (23ºC±3ºC, <70%RH) |
Turns ratio | Display of 3 kinds of turns ratio: Measured turns ratio in primary and secondary circuit; The conversion ratio of secondary loop 5A is taken; With the conversion ratio of 10kV-YY of the transformer 10kV/380V) The maximum conversion ratio is 1:10 million. |
Data storage | 3000 groups, press the HOLD key to keep data, and data is numbered automatically (the data will not be lost if there is power failure or battery replacement. |
Line voltage | Current measurement in lines with insulating layer below 60kV, or in bare wire below 35kV. (5 sections of insulating rod is required) |
Data hold | Press the HOLD key to hole data, the HOLD symbol will be displayed, and then press again to cancel holding. |
Data review | Press HOLD and POWER simultaneously to enter data review interface. |
Overflow display | Exceeding measuring range overflow function: "OL A" icon display |
No signal indication | When main unit does not receive the transmitter's signal, it will prompt "no signal". |
Auto shut-down | Automatically shut-down after powering on for 15 minutes. |
Battery voltage | When the battery voltage is lower than 4.8V, indication is displayed to remind user to replace battery |
Meter's weight | Main unit: 330g(with battery) High voltage tester: 335g(with battery) LV current clamp: 150g Total: 5kg(with carrying case and insulating rod) |
External interference | Avoid extremely strong electromagnetic field Avoid 433MHz.and 315MHz co-channel frequency interference |
Working condition | -25ºC~45ºC, <80%RH |
Storage | -10ºC~60ºC, <70%RH |
Size of insulating rod | φ32mm, 1m/section, 5 sections |
LV current clamp lead | 2m |
Insulation strength | Insulating rod: AC 60kV/rms (5 sections of insulating rod are all connected, between two ends) Between main unit and tester: AC1000V/rms(between enclosure and screw) |
Structure | Drip-proof structure type II (high voltage tester) |
Ambient temperature | -10ºC~50ºC |
Ambient humidity | ≤85% |
Altitude | ≤2000m |