1). Has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability.
2). Peak maintenance, data preservation, data storage, wireless transmission and other functions.
3). The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact, bending resistance, high insulation, flexibility and other characteristics.
4). Adopting the latest CT technology and integrated mask digital technology.
3.Parameters:
Function | High voltage AC current measurement, low voltage AC current, leakage current measurement, on-line AC current supervision. |
Power Supply | DC6V Alkaline Dry Battery (1.5V AAA X 4) |
Test Method | Clamp CT, Integral Method |
Transmission Method | Wireless Transmission, the maximum distance for direct transmission is about 30m. |
Display Mode | 4 digital LCD display, backlight function, suitable for dark place. |
LCD Dimension | 47mm×28.5mm |
Meter Dimension | W/H/T: 76mm×255mm×31mm |
Clamp Diameter | φ48mm |
Sampling Speed | About 2 times/second |
Range of measurement | 0.1mA~1000A(50/60Hz Auto Identification) |
Resolution | 0.1mA |
Gearing | 0.1mA~1000A Automatic Shift |
Test Accuracy(23ºC±5ºC, 80%RH) | 0.1mA~299mA: ±1%±3dgt |
0.30A~9.99A:±1.5%±5dgt | |
10.0A~199.9A:±2%±5dgt | |
200A~399A:±2.5%±5dgt | |
400A~600A:±3%±5dgt | |
601A~1000A:±4%±5dgt | |
Data Storage | 99 Groups, during storage, the symbol "MEM" gives indication, "FULL" mark will flash to indicate the memory has been full. |
Circuit Voltage | Test for the circuit below 60KV (operated with insulation rod) |
Peak Maintenance | Automatically maintain the height of the test value, usually in the test mode press PEAK key, PEAK lights, that is, to keep open the PEAK function, then press PEAK key to cancel this function |
Data Preservation | Under general test mode, press HOLD button to preserve data, "HOLD" symbol display. then press HOLD Key to cancel this function |
Data Access | "MR" symbol indicates, it can read the stored data by turning upwards and downwards. |
Overflow Display | Exceed measurement range overflow function: "OL A" symbol display |
No signal Indication | When the receiver has not received transmit signal, it will display "no- -"symbol |
Auto Shut Down | About 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption. |
Battery Voltage | When the battery voltage is below 4.8V, the symbol of battery voltage" "will show to remind to replace battery. |
Weight | Tester: About 335g (Including battery), total quality of meter: about 2.5Kg (including insulation rod and battery.) |
Work Temperature and Humidity | -10ºC~40ºC;80%Rh |
Storage Temperature and Humidity | -10ºC~60ºC;70%Rh |
Insulated Rod Dimension | φ32mm,1m/Section(5 Sections) |
Insulation Intension | AC 100KV/rms (Between 5th insulation rod and clamp core) |
Structure | Anti-Dripping Type II |
Wuhan WG Hipot Electric Tester Co.,Ltd. (hereafter referred to as WG Hipot) is the professional factory of high voltage testing equipment with over 15 years industry experience.
ISO Certified factory, qualified R&D and after-sales Engineer team, 3000 square meters workshop, our high voltage testers cover full range: High voltage hipot tester, Circuit breaker Switchgear Tester, Transformer tester, Relay Protection Tester, CT/PT Tester, MOA/Insulator Tester, SF6/Insulation Oil Test Equipment, Resistance Tester, etc.
Since 2003, with the support from our investors Wuhan High Voltage Institution and Xi'an High Voltage Institution, WG Hipot established and pioneered in high voltage testing field in domestic market as the designated supplier for State Grid and mainstream power companies.
Meantime, WG Hipot has developed overseas markets across 5 continents worldwide. We gained good feedback from our customers with our high performance, good quality, customized specification and easy-to-operate high voltage testers, which can be widely used in railway, oil and chemical industry, electricity grid, university, big factory etc.
III.Customer Visit:
IV.Filed Test&Service:
V.Certification:
VI.Package & Shipment:
VII. FAQ
1.When can I get the price?
We usually quote within 6hours after we get your inquiry. If you are vey urgent to get price, please call us or tell us in your email so that we will regard your inquiry priority.
2. What about the leading time for production?
Honestly, it depends on the order quantity and the product. Usually our leading time is within 7 working days after order confirmed.
3. What is your payment terms?
We accept EXW,FOB, CFR, CIF, ect. You can choose the one which is the most convenient and cost effective for you.
4. How much will be the Shipping cost and time?
This will depend on the size of your goods and the method of shipping (by sea/ by air/by Express) and your designated port or airport. We will be grateful if you can spare us some minutes to evaluate the cost based on the information provided.
5. Could you please tell me the Warranty Period of your product?
Our warranty period is one year free and lifelong maintenance. If the product is damaged (if not man-made damage), in the first year,we will send free parts for replacement. Over warranty, maintenance is paid service.
6. What kind of Certificate can you provide?
We can provide the CE mark, ISO 9001 quality certificate, third party calibration certificate(CNAS) and factory test report.
7. Do you have Technical Backup to all customers from different countries?
To be sure,our technical support is always available and quick response.
We are manufacturer with much on-site testing experience, thus we know how to deal with your problems. Moreover, our engineers can go to your country to support if need.