Zgf Leakage Current Test DC Hipot High Voltage Testing Equipment

China Zgf Leakage Current Test DC Hipot High Voltage Testing Equipment, Find details about China Generator, Zgf from Zgf Leakage Current Test DC Hipot High Voltage Testing Equipment

Model NO.
SYNY-0012ZGF
Over-Voltage Setting Error
≤1.0%
0.75 Switch Error
≤0.5%
Max Resolution
0.1%
Environment Temperature
≤85rh
Transport Package
Wooden Case
Origin
Shanghai, China
HS Code
9030339000
Model NO.
SYNY-0012ZGF
Over-Voltage Setting Error
≤1.0%
0.75 Switch Error
≤0.5%
Max Resolution
0.1%
Environment Temperature
≤85rh
Transport Package
Wooden Case
Origin
Shanghai, China
HS Code
9030339000

Application

ZGF type DC high voltage generator used AIPWM technique, adjusted the inaccuracy linearity of PWM technology, let the instrument precision greatly improved. It is mainly used in the electric power department, power department of industrial and mining, metallurgy, iron and steel enterprise for zinc oxide lightning arrester, power cables, transformers, circuit breakers, generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test.

Features

1.Large voltage feedback, high output voltage stability, small ripple coefficient.
2. It has grounding protection and prompt function.
3.Multiple protection: it has the function of internal over-current, external over-voltage and over-current protection.
4.Non-zero protection: coarse potentiometer does not return to zero, high voltage cannot start.
5.Voltage protection setting: set the over-voltage protection value according to the voltage value required by the experiment.
6.Structural features: epoxy glass fiber reinforced plastic electrical insulation double cylinder, air insulation, no leakage worry.
7.75% uDC-1mA function button to facilitate zinc oxide arrester test.
8.Over-voltage protection using dial code settings, at a glance.
9.The tested product has no capacity limit and can be charged with 1.5 times of rated current.
10.Vertical and horizontal dual-use international standard chassis, folding support foot, large diameter and area, good stability, field use more convenient.

Technical specification

Input Voltage AC 220V±10%;50HzOutput Voltage 0~500kV
Output Current0~20mARipple Coefficient≤1.0%
Voltage Adjustment Precision≤0.5%Measurement Error≤0.5%
Over-voltage Setting Error ≤1.0%0.75 Switch Error≤0.5%
Max Resolution0.1%Environment Temperature Environment≤85RH

Company Profile

Zgf Leakage Current Test DC Hipot High Voltage Testing Equipment

Certifications

Zgf Leakage Current Test DC Hipot High Voltage Testing Equipment

Packaging & Shipping

Zgf Leakage Current Test DC Hipot High Voltage Testing Equipment