China High Accuracy Rogowski Coil Integrator with Shield Aluminium Alloy Enclosure, Find details about China Integrate and Amplify Signals, Integrated Signal Convertor from High Accuracy Rogowski Coil Integrator with Shield Aluminium Alloy Enclosure
Advantage • High read accuracy 0.2% • Wide power supply arrange:4-12VDC or 24VDC • High bandwidth for measurement 5 to 20kHz • Lower zero drift down to 1.5mV Related Products A-Y-FCT and A-FCT | Applications Measuring devices, lab instrumentation • Power monitoring & control systems • Harmonics and transients monitoring • DC ripple measurement • Welding machine control • High current measurement |
Model | S1.1 | S1.2 | S1.3 |
Rated output | 5V AC rms | 5V DC(true-rms) | 4-20mA |
Maximum Output(overload) | 10V AC rms | 10V DC | 25mA |
Output Ripple factor | 0.2% | Default 5% (relay to Response time) | |
Response time | ≤1us | Default 100ms(adjustable) | |
Power consumption | 150mW | 200mW | |
Rated Input | 600A 3000A 10000A ... 100kA | ||
Read Accuracy | 0.2% typical at 1% to 200% of rated Current @25ºC | ||
Phase error | ≤0.5° | ||
Linearity | ±0.2% of reading(1% to 200% of range) | ||
Bandwidth | 5Hz to 50kHz(-3dB) | ||
Minimum Current measurement | 500mA (Ripple 100mA) | ||
Output on 0A (zero drift) | ≤1.5mV | ||
Temperature drift | 200ppm/ºC | ||
Weight | 155g | ||
Dimension | 86*90*29mm | ||
Power supply | 4-12V or 24V(best performance on 4-12V default) | ||
Operating temperature | -20ºC to 70ºC | ||
Storage temperature | -30ºC to 90ºC | ||
Relative humidity: | 80% max.without condensation | ||
Protection degree: | IP20 | ||
Other requirements, please contact us to OEM. |
Coil Model | Coil diameter (mm) | Output ratio and tolerance | Signal cable length |
Code:Y-FCT | Code:200(Typical rated 500A) Code:350(Typical rated 1500A) Code:510(Typical rated 3kA) Code:800(Typical rated 10kA) Y-FCT code is length. | Code:110 110mV/kA@50Hz±5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | Code:-2m Code:-5m Code:-10m Code:-20m |
Code:NRC | Code:100(Typical rated 1kA) Code:150(Typical rated 3kA) Code:200(Typical rated 6kA) | ||
Code:MRC | Code:16(Typical rated 100A) Code:24(Typical rated 300A) Code:36(Typical rated 600A) | Code:60 60mV/kA@50Hz±5% Code:50 50mV/kA@50Hz±0.5% | |
Code:SRC | Code:50 Code:100 Code:150 | Code:360 360mV/kA@50Hz±5% Code:333 333mV/kA@50Hz±0.5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | |
Other requirement could be OEM |
Integrator | Output form | Output value | Rated current | Power supply |
Code:D1 (DIN-RAIL integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -5(5V) | Code: -600A Code: -1kA Code: -3kA Code: -6kA | Code: -12(12V DC) Code: -24(24V DC) |
Code: .3(4-20mA output) | N/A | |||
Code:S9 (mini integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -3(3V) | Code: -12(6-12V DC) Code: -24(24V DC) | |
Code:S1 (high accuracy integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -5(5V) Code: -10(10V) | Code: -12(4-12V DC) Code: -24(24V DC) | |
Code: .3(4-20mA output) | N/A | |||
Code:ATP-01 (1A output three phase integrator) | N/A(0-1A) | N/A | Code: -12(12V DC) Code: -24(24V DC) | |
Code:A01 (1A output integrator) | N/A(0-1A) | N/A | N/A(85-265V AC DC) | |
Code:A05 (5A output integrator) | N/A(0-5A) | N/A | N/A(85-265V AC DC) | |
Code:HF (high frequency integrator) | N/A(0-10VAC peak) | N/A | Code: -1kA(1kA/1V) Code: -10kA(10kA/1V) | N/A(4-12V DC) |
Other requirement could be OEM |