120kV /2mA Portable DC Hipot Tester GDZG-300

China 120kV/2mA Portable DC Hipot Tester GDZG-300, Find details about China DC Hipot Tester, HV Generator from 120kV/2mA Portable DC Hipot Tester GDZG-300

Model NO.
GDZG-300 120kV/2mA
Over-voltage set value erro
≤1%
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030339000
Model NO.
GDZG-300 120kV/2mA
Over-voltage set value erro
≤1%
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030339000
120kV/2mA Portable DC Hipot Tester GDZG-300

Specification:

Output voltage120KV
Output current2mA
Output power240W
Ripple≤1%
Current precision≤1%
Voltage precision1% ±1 word
Over-voltage set value error≤1%
Control weight4kg
Voltage-multiple weight4.8kg
Voltage-multiple Height110*640mm

Application:

1) MOA lightening-arrester HVDC hi-pot
2) HVDC hi-pot and leak current measurement for HV electrical equipment, such as transformer, switchgear, and oil-type
power cable
3) Leak current measurement for water-cooling DC power generators
4) High-stability DC HV generators with high-precision DC voltage-divider for DC HV standardization

Main Feature:

1) Co-formed the industry product standards: "ZBF24003-90 Portable DC HV Generator Common Technical Conditions" and
2) "DLT 848.1-2004 HV Testing Equipment Common Technical Conditions, Part One: DC HV Generator"
3) From the first PWM regulated DC HV generator in China developed in 1992, till today, the DC HV generator series has been sold to 1000 customers with 2857 sales volume till the end of 2013
4) DC HV Generators generate: output voltage 40~1200kV, and output current 2~300mA
5) Highest stability could reach ≤0.05%; Ripple≤0.1%
6) Double-stage voltage-multiplier designed for various test precision requirement
7) Controller and voltage-multiplier can be integrated into a single unit (40kV type) for the convenience of field application
8) ZV-B fully-shielded micro ammeter: digital LCD covered by conductive glass joint with metal shell, test and shielding cable coaxially led out
9) HV-B Infrared micro-ammeter (optional): Infrared connection, auto test individual and total leak current of double arresters
10) Voltage auto-raise/multi-point test (upgraded Z-VII type): pre-set test voltage, test and record leak current on multi-level voltage
11) Voltage-test open circuit protection, ground protection for the safety of operators
12) Can tolerate HV arcing from large-capacity capacitive test object

120kV/2mA Portable DC Hipot Tester GDZG-300