High Frequency Mobile C-Arm System

China High Frequency Mobile C-Arm System, Find details about China C Arm, Medical Equipment from High Frequency Mobile C-Arm System

Model NO.
AJ-112C
C-Arm Open Distance
760mm
C-Arm Arc Depth
640mm
Trademark
ANJUE
Specification
CE ISO FDA EEC
Origin
China
Model NO.
AJ-112C
C-Arm Open Distance
760mm
C-Arm Arc Depth
640mm
Trademark
ANJUE
Specification
CE ISO FDA EEC
Origin
China

High Frequency Mobile C-Arm System
Usage
Orthopedics: restore bone translocation, reset, fixing
Surgery: taking foreign bodies out of the body, cardiac catheterization, implantable pacemakers, some of angiography and local photography etc.
 
Features
1. Continuous pulse fluoroscope, it's convenient to connect digital subtraction system.
2. With mega-pixel digital CCD photography, the image is clearer.
3. With unique image software processing technique, the image is clearer for doctors to operate and diagnose. Standard DICOM interface, it's convenient to exchange information with hospitals.
4. Pulse fluoroscope has the advantage of low dose and clearer image, so it meets the needs of high precision, high difficulty minimally invasive surgery, which well protect the security of operator and patient.
5. Unique double foot brake controller design makes it convenient to control the instrument inside and outside the operation room. This design can also protect the health care professionals by reducing the probability to come into contact with the radiation.
6. Exclusive inside and outside monitor design makes it more convenient to observe the operation process either inside or outside the operation room. At the same time, this design can facilitate the outdoor teaching and the real-time observation of the surgical procedures.
7. With high-quality combined high frequency high-voltage X-ray generator, it can greatly reduce the amount of X-ray irradiation.
8. With a perspective KV, MA automatic tracking feature, so that the image brightness, sharpness automatically in the best condition
9. Adopting imported image intensifier, the quality is stable and reliable, and the image is of good clarity.
10. With unique base electric auxiliary support arm design, so it's safer.
11. A unique hand-held controller design, which can control parameter set, equipment movement and radiation field, so the operation is more convenient.
12. With new design of mainframe, the appearance is compact and beautiful.
 
Standard Configurations
1. C-arm Mainframe    1 set
2. Combined high-frequency high-voltage X-ray generator and high-frequency power supply (5.0kW, 40 kHz, 120kV)    1 set
3. Imported 9 inch image intensifier    1 set
4. Medical mega-pixel ultra-low illumination digital radiography    1 set
5. Digital acquisition and processing station (See workstation list for detail information)    1 set
6. Imported dense grain grids    1 set
7. Electrical adjustable beam limiting device    1 set
8.19 inch IM medical LCD grayscale display    1 set
9.14 inch high-definition medical VGA interface (no flicker)    1 set
10. Unique hand-held controller    1 set
 
CategoryItemsContent
ModelAJ-112C
Electrical PerformanceHigh frequency inverter power supplyPower:3.5KW
Inverter frequency: 40 kHz
Automatic fluoroscopyTube voltage :40 kv~120kv
Tube current: 0.3mA~~4mA 
Manual fluoroscopyTube voltage :40 kv~120kv
Tube current: 0.3mA~~4mA 
Pulse fluoroscopyTube voltage:40 kv~120kv, continuous
Tube current : 4.1mA~~30mA continuous
Photography tube voltage, tube current mAs40KV~120KV, 20~100mA , 1~180 mAs
X-ray TubeX-ray tube special for high frequencyLarge focus:1.5,Small focus :0.3 
Thermal capacity: 650kJ (867 kHu)
Imaging SystemImage intensifierImported  TOSHIBA  9 inch image intensifier 
CCD photographyMega-Pixel digital medical CCD radiography 12 bit
Monitor19 inch IM medical LCD grayscale display 
14 inch high-definition medical VGA interface
Center definition is 1000 lines and frequency for picture refresh is 60 Hz.
CCU (central control)Real-time acquisition, continuous adjustable recursion, many images storage, up and down image, left and right image, image patching, LIH (last image freeze)
Structure and performanceDirection wheel and main wheelDirection wheel can rotate in any direction, and main wheel can rotate in ±90°.
C-armThe up and down electrical stroke of pillar is 400mm.             
Forward and backward movement:200mm;
Revolution around horizontal axis : ±180°;                      
Revolution around vertical axis: ±15°,
Slipping on orbit : 120°(+90°~-30°)                           
SID: 960 mm;
C-arm open distance: 760mm                                
C-arm arc depth: 640mm;
Plate holder size200mmx250mm(8"x10") or 250mmx300mm(10"x12")