China ASTM D6304 Lubricating Oil Coulometric Karl Fischer Drip Device, Find details about China Karl Fischer Titrator, Coulometric Karl Fischer Titrator from ASTM D6304 Lubricating Oil Coulometric Karl Fischer Drip Device
I. Introduction:
This Coulometric Karl Fischer Titrator is controlled by LCD touch screen, and it has the functions of automatic inhalation of reagents, automatic calculation, data storage, printing, reagent failure reminder and automatic waste liquid discharge, with a resolution of 0.1ppm.
II.Features:
1.MA-30 Intelligent Karl Fischer Moisture Analyzer is upgraded on the basis of MA-3 Intelligent Karl Fischer Moisture Analyzer.
A new calibration procedure is added. Through standard sample calibration, the system gain coefficient can be fine-tuned by software to be infinitely close to the absolute accuracy value, and the moisture measurement accuracy can truly reach 1ppm;
The newly-added multi-functional pump makes the instrument have the functions of automatic inhalation of reagents and automatic discharge of waste liquid;
2.Newly added automatic tracking function of reagent consumption, automatic reminder of reagent failure;
3.Newly added moisture measurement speed adjustment function, customers can adjust the measurement speed according to the analysis requirements. For example, if the customer does not require high accuracy, the test speed can be adjusted faster, and if the accuracy is high, the measurement speed needs to be slowed down.
4.The Coulometric Karl Fischer Titrator adopts LCD large-screen touch display, rich software interface content, Chinese/English character prompts for operation content, flexible and convenient man-machine dialogue, in addition to the characteristics of high detection sensitivity, simple operation, fast test speed, and good repeatability, it also conforms to international standards. The literature has the function of water absorption measurement;
5.Test result storage and printing function; the sample measurement process is automatically controlled by the instrument, stirring and measurement are automatically completed in about 60 seconds, and the measurement result is displayed directly; the fully sealed titration cell bottle avoids contact between reagents and humans and avoids the influence of environmental humidity;
6.This Coulometric Karl Fischer Titrator has a Chinese/English LCD display, and has automatic calculation and printing functions. It can print out the percentage, sample number, operator, experiment date, etc.
III.Specifications:
Measuring range | 0.00001% (0.1ppm) to 100% |
Resolution | 0.1ppm |
Repeatability | 0.0002 |
Linear correlation coefficient of moisture titration | ≥0.9998 |
Power supply | AC 220V±10%, 50Hz |
Power consumption | less than 50W |
Working environment temperature | 5ºC-40ºC |
Working environment humidity | 85% |