500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set

China 500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set, Find details about China Coke Oven Gas, Gas Generator Set from 500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set

Model NO.
CP500GFJ11
Transport Package
Standard Export Wooden Packaging
Origin
China
HS Code
8502200000
Model NO.
CP500GFJ11
Transport Package
Standard Export Wooden Packaging
Origin
China
HS Code
8502200000

Product Photo Display

 
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set
 
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set
 
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set


 
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set
500kw Coke Oven Gas 12V190 Series Lcv High Power Generation Efficiency Gas Generator Set


Gas Introduction

Gas Composition and Calorific Value Parameter Table
Gas TypeComposition(Volume%)Low Calorific Value MJ/Nm3
Coke Oven GasCH4CnHmCOH2CO2O2N218.3
272656315

Coke Oven Gas(COG), due to the diversity of combustible components, it belongs to high calorific value gas, raw gas or crude gas. COG is the product of several types of bituminous coal compounded into coking coal, in the coke oven after high temperature dry distillation, in the output of coke and tar products at the same time produced by a flammable gas, is a by-product of the coking industry.Coke oven gas is a mixture, its main components are hydrogen (55%~60%) and methane (23%~27%), in addition to contain a small amount of carbon monoxide (5%~8%), C2 and above unsaturated hydrocarbons (2%~4%), carbon dioxide (1.5%~3%), oxygen (0.3%~0.8%)), nitrogen (3%~7%).Because of the high hydrogen content, coke oven gas needs to solve the problem of detonation and tempering when it is used in internal combustion generator set to generate electricity. knocking and backfire issues need to be solved while using for internal combustion genset power generation.

CR Genset Introduction

ComeRiver Power oil producer gas generator set is aiming at the gas exploitation with high hydrogen content and high carbon monoxide content, the genset is fully optimized and designed based on the general genset. The genset adopts modular design, engine, alternator and intercooler are the three major modules which the middle part is the engine, easier for daily maintenance, gas intake and exhaust, the cooling water is placed at the free end, that is easier for power plant installation and arrangement.
The engine adopts double turbocharging dual shunt intake technology, and it is special designed for generator set with hydrogen content included, reliable structure design, safety operation feature, and after the optimization of the double turbocharges, a higher efficiency will provide a more efficient turbocharging pressure, thereby the genset operation power and efficiency definitely will have a obvious improvement.
The product has the features of high efficiency, low energy consumption, and low emission, etc.. The genset core control system components are all fully automatized, including ECU, air-fuel control system, speed regulating system, and ignition system, etc., product quality is extraordinary reliable and these are already widely applied on the gas generator sets. Genset adopts SE3 control system, perfect man-machine interaction and better maneuverability. ComeRiver Power genset combines advantages of high-performance engine, core control components and advanced gas genset control system, and it has been highly recognized by clients on the market.

High Power

Under the condition that the gas source and operating environment meet the requirements, the maximum power of the genset is 700KW.

High efficiency

The double turbocharging technology has been optimized and verified for a long period, with reliable structure and high operating efficiency, thereby the genset is able to run for a long time at full loading.

Good reliability

All major components are being fully optimized . genset owns comprehensive control system functions, complete parameter gathering and wide protection range.

Good adaptability

The genset is specially optimized with various adjustment and control, which can adapt to the change of gas source on site.

Easy operation and maintenance

The three-section modular design makes the genset easy to maintain. The control system has a high degree of automation. Easy to operate.

CR Genset Parameter Tables

Genset Container Parameters
Boundary dimension of container(L×W×H, as a useful reference for transportation),unit: mm10450×3000×3000
Noise at 1m away from the gas genset, unit: dB(A)≤85
Total Weight (Ton)25
 
Coke Oven Gas Generator Set Parameter
Parameter DescriptionsParameters
Genset Series11 Series(12V190)
Genset ModelCP500GFJ11
Rated power, kW500
Rated current, A902/57.3/34.4
Rated voltage, V400/6300/10500
Rated frequency, Hz50/60
Rated rotation speed, r/min1000/1200
Rated power coefficient, cosΦ0.8
Oil Heat Consumption, g/(kW·h)0.5
Property GradeG2
Phase Number & Wiring Method3 Phase 3 Wire or 3 Phase 4 Wire
Pressure Adjustment MethodAutomatic Voltage Control
Excitation MethodBrushless Excitation
Starting MethodDC24V Electrical Starting
Boundary Dimension(LxBxH), mm6200×1950×2175
Net Weight, kg11200
 
Engine Parameters 
Model of engineCP12V190-500-02
Configuration and typeShunt Intake, turbocharging intercooler
Cylinder arrangementV-Type 60° Angle
No. of cylinder12
Cylinder diameter, mm190
Piston working Distance, mm210
Total displacement (L)71.45
Rated speed(r/min)1000
Idle speed(r/min)600
Rated power(kW)540
Lube oil consumption (g/kWh)0.8
High outlet water temp(ºC)60~75
Low outlet water temp(ºC)28~48
Lube oil temp (ºC)65~80
Lube oil pressure in oil main line(kPa)500~800
Lube oil pressure in turbocharger (kPa)250~450
Stable speed drop0~5 Adjustable
Lubricating systemPressure and splatter combined lubrication method
Ignition methodSparking plug electric ignition
Starting methodDC24V Electrical Starting
Direction of rotationCounterclockwise (facing the output end)
Speed RegulationElectronic Speed Regulating
Cooling systemForced Circulation Water Cooling
Output wayFlywheel output
 
Alternator Parameters 
Alternator model-11FC6 455-6LA42
Output power(kVA)625
Rated speed(r/min)1000
Rated voltage(V) 400
Rated current(A) 722
Frequency(Hz)50
Power factor(lag)0.8
Insulation ClauseF Grade
Direction of rotationClockwise(face to shaft end)
Protection ClauseIP23
Cooling methodAir Cooling
  
Alternator model-2JFG 500-6/6300
Output power(kVA)625
Rated speed(r/min)1000
Rated voltage(V) 6300
Rated current(A) 57.3
Frequency(Hz)50
Power factor(lag)0.8
Insulation ClauseF Grade
Direction of rotationClockwise(face to shaft end)
Protection ClauseIP23
Cooling methodAir Cooling
  
Alternator model-3JFG 500-6/10500
Output power(kVA)625
Rated speed(r/min)1000
Rated voltage(V) 10500
Rated current(A) 34.4
Frequency(Hz)50
Power factor(lag)0.8
Insulation ClauseF Grade
Direction of rotationClockwise(face to shaft end)
Protection ClauseIP23
Cooling methodAir Cooling

CR Technical Advantages

Three-Section Modular Design

Genset adopts three-section modular design, including gas engine, turbocharging intercooler three modules and the design improved the genset maintenance operation;
Engine places at the middle, fewer auxiliary equipment on both sides, which is convenient for daily maintenance; the intake and exhaust are concentrated in the free end, which is convenient for the layout of the power station. The three modules are evenly distributed to make the mass distribution of the genset more uniform and easier to hoisting.

Shunt Intake technology

Due to coke oven gas with characterizations of containing hydrogen and low methane value, the burning speed is fast, backfire and knock are likely to be caused, ComeRiver adopts shunt intake technology with a reliable structure, compared with the multi-point electric injection and mechanical injection, shunt intake technology has a simple and reliable control mechanism; the possibility of backfire occurring is being avoided completely.

Shunt Pressurization Technology

Adopting the shunt pressurization technology, the genset operation safety is high, the gas does not need other auxiliary pressurization equipment, it is not only saves energy consumption, but also the low pressure gas intake is realized.

Single Cylinder Control Technology

Single cylinder control technology is adopted to control and protect the combustion of each cylinder separately to improve the safety and reliability of genset operation.

High Extent of Automation

Control system has the feature of perfect man-machine interaction, easy to operate. High extent of automation, human intervention is unnecessary under normal operation. The system has the functions of air-fuel ratio control, speed regulating control, pressurization bypass control, system self-adaptation, and system protection, etc.

Core Components Comprehensive Automation

All core components are independent designed, including ECU, air-fuel control system, speed regulating system, and ignition system.

Multiple Choices of Genset Type
Multiple options of regular gensets and containerized gensets;
Multiple options of voltage grades, 400V,6.3kV,10.5kV;
Special designs accord to the application mode.


FAQ

  1. Are you a trading company or manufacture?
    Manufacture with factory.
  2. What kinds of gas generator set do you produce?
    It covers for all kinds of gas produced in industry, including biomass gas, biogas, natural gas, coal mine gas, coke oven gas, syngas, industrial exhaust gas, and etc. as well as related gas produce equipment.
  3. What is your delivery time?
    Normally within 60 days after receiving the 40% contract value advance payment. It depends on the configuration and quantity, please confirm with us before order.
  4. What is your payment terms?
    Normally paying by T/T, L/C, other payment method available according to customer's requirement.
  5. 6.What is your available port of shipment?
    Normally Qingdao port, other ports available according to customers' requirement.
  6. What is your standard packing?
    All the goods will be packed by standard export wooden packaging or container, suitable for long-distance sea transportation, moisture-proof, earthquake, rust-proof. Special packing method can be accepted when needed.
  7. What is the MIN order quantity ?
    Normally 1 generator set.
  8. What is the warranty?
    12 months after the completion date of commissioning, or no later than 15 months after the delivery date on the B/L, Whichever comes first (Not including consumable parts).
  9. How could I be sole agent?
    Since we build cooperation, we will consider your order quantity and if you want, we will try our best to meet your demand.