Pathology Automatic, Automated Cryostat Microtome

China Pathology Automatic, Automated Cryostat Microtome, Find details about China Microtome, Rotary Microtome from Pathology Automatic, Automated Cryostat Microtome

Model NO.
BKCM-295
Trademark
BIOBASE
Specification
Automatic type
Origin
China
Model NO.
BKCM-295
Trademark
BIOBASE
Specification
Automatic type
Origin
China
Pathology Automatic, Automated Cryostat Microtome

Pathology Automatic, Automated Cryostat Microtome



Design Features
*It is designed under overall engineering and ergonomic concept. All the components are processed with computer numerical controlled machine
*Specimen retraction function, protects specimen from blade injury
*Trimming/Cutting button makes it easy to switch from trim and section mode
*Equip with counter to calculate total pieces and thickness. 
*Dual compressors, which are made in Germany, freeze the cryostat chamber, freezing shelf, knife holder and specimen clamp separate with pro-environment refrigerant R404
*Temperature can drop to working condition in 60 minutes after switching on. 
*Adopt to UVC sterilize for 35 minutes every time.  
*Peltier may be on or off manually.
*Heated, removable sliding window.
*Two defrost methods: definite time and manual 
*The high-precision microtome is enclosed outside the cryostat chamber to protect it                                   from thermal expansion and contraction and keep minimum service and maintenance. 
*Self-explanatory symbols for all functions and displays, easy to learn and operate. 
*LED screen can display data such as sample travel, thickness, function controlling, day, time, temperature, timed on/off and so on
*Stand by mode, after initializing, the temperature in cryostat chamber can be controlled between -4ºC an -9ºC by computer automatically; when stop initializing, the temperature
 in freeze chamber will arrive to working temperature within 10 minutes
*Control panel with locking function to avoid wrong operation.
*Handwheel locking 
*Sensor self-diagnosis function.
*Wide freezing shelf may put 10 specimen cassettes
 
Technical Specifications
ModelBKCM-295 
Freeze chamber temperature range-10ºC~-30ºC
Cooling to -30ºC time 60 min
Freeze shelf minimum temperature-45ºC
Lowest temperature of Peltier unit 
on freeze shelf
-55ºC
Peltier working time15 minutes
Maximum specimen size35mm×35mm
Specimen vertical stroke60mm
Specimen horizontal stroke20mm
Coarse feeding speed0.7mm/s; 0.35mm/s
Section thickness range1μm~80μm adjustable 
1μm~20μm, in 1μm increment
20μm~40μm, in 2μm increments  
40μm~80μm, in 5μm increments
Trimming thickness range10μm~400μm adjustable; 
10μm~50μm, in 5μm increments;
50μm~100μm,in 10μm increments; 100μm~400μm, in 50μm increments;
Retraction range0μm~80μm adjustable; in 5μm increment
Voltage and frequencyAC220V±10%   50Hz(Standard) 
Special requirement may customize by order. 
Power850W
Net weight130kg
125kg660×640×1130mm
Package size790*790*1370mm 
Gross weight170kg
 
Pathology Automatic, Automated Cryostat Microtome