ASTM D240 Automatic Coke Bomb Calorimeter with Computer

China ASTM D240 Automatic Coke Bomb Calorimeter with Computer, Find details about China Automatic Calorimeter, Automated Calorimeter from ASTM D240 Automatic Coke Bomb Calorimeter with Computer

Model NO.
GDY-1C
Size
69*55*48;45*37*25;58*52*84
Weight
28, 10, 25kgs
Service
Engineer Available to Service Overseas
Trademark
GOLD
Transport Package
Packed in Veneer Case
Specification
69*55*48; 45*37*25; 58*52*84
Origin
Chongqing, China
HS Code
9031809090
Model NO.
GDY-1C
Size
69*55*48;45*37*25;58*52*84
Weight
28, 10, 25kgs
Service
Engineer Available to Service Overseas
Trademark
GOLD
Transport Package
Packed in Veneer Case
Specification
69*55*48; 45*37*25; 58*52*84
Origin
Chongqing, China
HS Code
9031809090
GDY-1C Oxygen Bomb Calorimeter
 
Introduction:
The instrument is designed and made as per:
National Standard GB/T213 "Test Methods for Heat of Coal", 
National Standard GB/T384 "Test Methods for Calorific Value of Petroleum Products", 
National Measurement and Determination Specification JJG672 "Oxygen Bomb Calorimeter", 
Shanghai Company Standard "Q/YXYY-10 GDY-1 Oxygen Bomb Calorimeter". 
 
It has been widely used to determine heat value of coal, oils, tar, and paraffin, etc. It is the desired instrument for power plants, smelting, cement, and petrochemical, scientific research institutes, and colleges and universities.
 
Main characteristics:
u Equipped with a desktop computer, so you can control whole test procedures through a computer;
u It can make determination automatically without manual control, and it can record and save all test data automatically;
u Equipped with test software. It has function of man-machine conversation, user-friendly interface, and operation convenience;
 
Technical parameters:
Heat capacity: 14000~15000J/K;
Temperature measurement range: 10 ~ 35 centigrade;
Temperature resolution: 0.001 Centigrade;
Repeatability error:  ≤0.2 % (Grade C);
Endured pressure in oxygen bomb: 20 MPa;
Operation environment temperature: 15 ~ 28Centigrade (Ambient temperature); Temperature fluctuation is not more than 1 Centigrade during a test;
Ambient humidity: less than 85%;
Power supply: AC 220V±5%, 50 Hz;

 
Heat capacity  14000~15000J/K
  Temperature measurement range  10 ~ 35Centigrade
  Temperature resolution  0.001 Centigrade
  Repeatability error  ≤0.2 % (Grade C)
  Endured pressure in oxygen bomb  20 MPa
Operation environment temperature  15 ~ 28Centigrade (Ambient temperature); Temperature fluctuation is not more than 1Centigrade during a test;
  Ambient humidity   less than 85%
  Power supply  AC 220V±5%, 50 Hz