China Square Analog Panel Meter DC 100A Sq72 Ampere Meter, Find details about China Current Meter, DC Current Meter from Square Analog Panel Meter DC 100A Sq72 Ampere Meter
General Features | |
Cases | Material:ABS & PC(Anti-fire) Protection degree for class: IP52. Protection degree for terminals: IP00. |
Accuracy Class | 2.5/1.5 |
Working voltage | 650V |
Insulation | Insulation reference voltage 0.6KV |
Working temperature | -25ºC-55ºC |
Vibrations | ±0.25mm amoplitude at 50/60HZ |
Mounting position | The normal execution for our instruments is for vertical mounting. If other mounting positions are know in advance, please indicate the angle of inclination when ordering. |
Types | Model | Class | Specs | Advantage | Remark |
AC Ammeter | 96, 72, 48 | 1.5 | 0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 75-10KA(use Ext.CT5A) (Note: for 60/75/100A direct meter, the class is 2.5.) | The scale can be easily changed without opening the front frame so that the class will not be influenced. | Moving Iron |
AC Voltmeter | 96, 72, 48 | 1.5 | 30V 50V 75V 100V 120V 150V 250V 300V 450V 600V For 450-380kv,should be used with potential transformer secondary voltage 100V. | ||
DC Ammeter | 96, 72, 48 | 1.5 | 25uA 30uA 50uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA 200mA 250mA 300mA 500mA 1A 3A 5A 7.5A 10A 20A 30A 50A 75-10KA(used with shunt) (Note: for 60/75/100A direct meter, the class is 2.5.) | The scale can be easily changed without opening the front frame so that the class will not be influenced. | Moving Coil |
DC Voltmeter | 96, 72, 48 | 1.5 | 3V 5V 7.5V 10V 15V 20V 30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 600V (Note: Over 600V should be used with Ext. resistor.(Rated current 5mA)) | ||
AC Ammeter | 96, 72, 48 | 1.5 | 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 75-10KA(use Ext. CT.) (Note: These meters measure r.m.s. values and scaled in r.m.s.) | Moving Iron with Rectifier | |
AC Voltmeter | 96, 72, 48 | 1.5 | 15V 20V 25V 30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 600V 450-450KV(use potential transformer) | ||
Frequency Meter | 96, 72, 48 | 1.0 | Volt: 50V 100V 220V 380V Freq: 45-55HZ 45-65HZ 55-65HZ 47-53HZ 57-63HZ 44-56HZ 54-66HZ 450-550HZ 550-650HZ | 90° scale | |
Power Meter | 96, 72 | 1.5 | Volt: 50V 100V 220V 240V 220/380V 240/415V Current: 5A | Wattmeters or Varmeters with build-in converter for 1phase,3P 3W, 3P 4W. | |
Power Factor Meter | 96, 72 | 2.5 | Volt: 100V 380V 440V Freq: 50HZ 60HZ Scale graduation: 0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind | For 3 phases circuits,balanced load 45-65HZ and for 1 phase AC50HZ | |
DC Moving Coil Ammeter | 96, 72 | 1.5 of F.S.D | 50uA-1mA-10A(Direct) 15A-5000A(with shunt) | Long Scale Meters | |
DC Moving Coil Voltmeter | 96, 72 | 1.5 of F.S.D | 45mV 50mV 60mV 75mV 1-600V | ||
AC Moving Coil with Rectifier Ammeter | 96, 72 | 1.5 of F.S.D | 10mA-10A Freq: 40/50/60HZ | Consumption: <3VA | |
AC Moving Coil with Rectifier Voltmeter | 96, 72 | 1.5 of F.S.D | 10-600V Freq: 40/50/60HZ | Consumption: <1.1VA | |
Frequency Meter | 96, 72 | 1.0 | Volt: 50V 100V 220V 380V Freq: 45-55HZ 45-65HZ 55-65HZ 47-53HZ 57-63HZ 44-56HZ 54-66HZ 450-550HZ 550-650HZ | ||
Wattmeter and Varmeter | 96, 72 | 1.5 | Volt: 50V 100V 220V 220/380V 240/415V Current: 5A | Wattmeters or Varmeters with build-in converter for 1phase,3P 3W, 3P 4W. | |
Power Factor Meter | 96, 72 | 1.5 | Volt: 100V 380V 440V Freq: 40HZ 50HZ 60HZ Scale graduation: 0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind | Used in 1P/3P circuits. |
Model | unit | A | B | C | D | E | F |
SQ96 | mm | 96 | 91 | 90 | 5.5 | 65 | 43 |
inch | 3.78 | 3.58 | 3.54 | 0.22 | 2.56 | 1.69 | |
SQ72 | mm | 72 | 67 | 66 | 5.5 | 65 | 43 |
inch | 2.83 | 2.64 | 2.6 | 0.22 | 2.56 | 1.69 | |
SQ48 | mm | 48 | 43 | 42 | 5.5 | 65 | 43 |
inch | 1.89 | 1.69 | 1.69 | 0.22 | 2.56 | 1.69 |