China Flammability Testing Equipment Needle Flame Tester for Plastic IEC 60695, Find details about China Needle Flame Tester, Flammability Testing Equipment from Flammability Testing Equipment Needle Flame Tester for Plastic IEC 60695
Model:
GD- 60695
Standard:
GB4706.1,GB5169.5-2008, IEC60695-2-2IEC60695-11-5
Comply with the relevant standards GB4706.1, GB5169.5-2008, IEC60695-2-2IEC60695-11-5 etc.
Technical Parameters:
1. Needle burner: stainless steel, the inner diameter of ¢ 0.5 ± 0.1mm, an outer diameter of not more than ¢ 0.9mm, length 35mm more needles, no air access;
2. The burner angle: vertical (when adjusting and measuring the flame height) or inclined 45 ° (the test);
3. Combustion gases: 95% butane gas or propane gas;
4. Ignited bedding layer: white pine plank (thickness 10mm), surface covering 12 ~ 30g / m2 standard tissue paper layer is applied at lower flame from 200mm ± 5mm;
5. Temperature range: 0--1000 ºC;
6. The flame temperature requirements: from 100 ± 2 ºC ~ 700 ºC ± 3 ºC, should be completed within 23.5 ± 1.0s;
7. The flame height: 12mm ± 1mm;
8. Shi burning time: 0s ~ 999.9s adjustable, generally set at the 30s;
9. Holding burning time: 0s ~ 999.9s, automatic recording, manual pause;
10. Test Space: ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements);
11. Temperature sensor: K-type insulation-sheathed thermocouple (Φ0.5mm);
12. Test program automatic control, independent ventilation system;
13. Dimensions: L1120 * W520 * H1250mm, exhaust Φ100mm;
14. Test Power: 220V / AC, 50H.
Specification:
Dimensions | L1120 * W520 * H1250mm |
The diameter of the exhaust | 100mm |
Test power supply | 220V / AC, 50Hz |
Temperature range | 0--1000 (Degree) |
The flame temperature requirements | 100±2~ 700ºC±3 (Degree) |
Heating rise time | 23.5±1.0s |