Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02

China Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02, Find details about China Dual Syringes, CT Injector System from Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02

Model NO.
MSLGT02
Flow Rate
0.1-10ml
Volume
0.1-200ml
Hold Capability
30 Minutes Max
Storage Capabilities
100 Protocols
Double Syringer CT Injector
Yes
Pressure Limit
50-350psi
Injection or Scan Delay
0 to 3599 Seconds in 1 Sec. Increments
Trademark
MSL
Origin
Guangdong China
Model NO.
MSLGT02
Flow Rate
0.1-10ml
Volume
0.1-200ml
Hold Capability
30 Minutes Max
Storage Capabilities
100 Protocols
Double Syringer CT Injector
Yes
Pressure Limit
50-350psi
Injection or Scan Delay
0 to 3599 Seconds in 1 Sec. Increments
Trademark
MSL
Origin
Guangdong China

Dual Syringes CT Injector MSLGT02 with reasonable price

Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02
Product Description
 
Item
Description
Injector Arm and Pedestal
Dimension: Length: 22.8″(58.0cm) Width: 12.5″(20.1cm) Height: 50.2″(127.4cm)

Weight: 19.5 Kg
Console
Dimension: Length: 4.55″(11.55cm) Width: 12.68″(31.8cm) Height: 9.77″(24.81cm)

Weight: 4.1 Kg

Color Touch Screen
Electrical
Requirements
a.c.198~242V/, 50/60Hz, 200VA
Operation
Interface
Selectable in English, French, German and Chinese
Flow Rate
0.1 mL/sec. to 10 mL/sec. in 0.1 mL/sec. increments
Syringe Capacity
115ml for Zenith-C11; 200ml for MSLGT02
Volume
0.1 ml to syringe capacity in 0.1 ml increments
Pressure
Preset limit: 300 psi default, user settable from 50 to 350 psi in 1 psi increments

Display: Real-time pressure curve

Change threshold: Stop injection if pressure changing suddenly

Alarm: Voice alarm and stop injection when over preset limit
Injection or Scan
Delay
0 to 3599 seconds in 1 sec. increments
Autofill
Settable flow rate from 3ml/sec. to 8ml/sec., volume from 10ml to syringe capability
Injection Capabilities
programmable up to 8 phases
Pause Phase
0~999 sec. in in 1 sec. increments
Hold Capability
30 minutes max
Storage Capabilities
100 protocols
Expel air locked
Unable to inject unless expelling air
Test injection
Settable flow rate from 0.1ml/sec. to 5ml/sec., in 0.1 ml increments, volume from 0.1ml to 10ml
Heat maintainer
35~38ºC (optional)
Hand switch
Hand switch control pause and continue injection (optional)
Emergency stop function
When the system is injecting, click on any point of the touch

screen or any button on the injection arm, the system will stop injection

Product Detail
Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02Dual Syringes CT Injector System CT Contrast Media Injector Mslgt02