High Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper Conductor

China High Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper Conductor, Find details about China Yjlw03, 500kv Cable from High Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper Conductor

Model NO.
YJLW03
Wire Core Material
Red Copper Wire
Certification
ISO, CCC, CE, RoHS, UL, VDE
Model
Yjlw03
Brand
Cangzhouhuiyou
Company Name
Cangzhou Huiyou Cable Stock Co., Ltd
Trademark
CANGZHOUHUIYOU
Transport Package
Iron Wood Shaft
Specification
1*2500mm2
Origin
China
HS Code
8544601900
Model NO.
YJLW03
Wire Core Material
Red Copper Wire
Certification
ISO, CCC, CE, RoHS, UL, VDE
Model
Yjlw03
Brand
Cangzhouhuiyou
Company Name
Cangzhou Huiyou Cable Stock Co., Ltd
Trademark
CANGZHOUHUIYOU
Transport Package
Iron Wood Shaft
Specification
1*2500mm2
Origin
China
HS Code
8544601900

500 KV XLPE Insulated Power Cable
1. Standard
We produced according to National Standard of GB/T 22078.2-2008 of the People's Republic of China.
2.  Range of application
It is suitable for single-core cable's installation and operation under normal conditions of rated voltage 290/500 KV, but it is not suitable for cable in special use, such as submarine cable.
3. Characteristics of cable
Rated voltage of cable is U0=290 KV,U=500 KV,Um=550 KV.
The allowable maximum temperature of cable conductor is 90ºC when it runs in normal, and 250ºC when it short circuited (Longest time is 5 s).
The allowable minimum bending radius is 20 times of cable outside diameter when installed. After installation  , the minimum bending radius is recommended for 15 times of cable outside diameter.

4. Service environment( Place )
Lead sheath cable, is suitable for environment with more serious corrosion but no much nitric acid, acetic acid and organic matter ( Such as mud, coal and strong alkaline corrosion matter with technical force, stress and vibration etc.)
Aluminium sheath cable, is suitable for environment with minor corrosion and required to bear a certain mechanical force ( For example, connected with transformer directly and laying at bridge opening or in shaft etc.)
Metal plastic compound sheath cable is suitable for general damp and warm place , no corrosion or light corrosion and no direct contact with water and bear not so much technical force , pulling force , stress and vibration.
PVC outer sheath cable is mainly used in cable line with general fire-proof requirement and insulation requirement for outer sheath.
PE outer sheath cable is mainly suitable for directly buried laying cable line with higher requirement on outer sheath insulation, low temperature environment under 20ºC, or soaked place by chemical liquid and low toxicity requirement when cable burns, when PE outer sheath is used in tunnel or shaft , fire-control and flame-retardant measures should be adopted if necessary.
 
  1.  Model and Name of product
ModelName of cable
Copper core
YJLW02XLPE insulated corrugated aluminium sheath or welding  aluminium sheath PVC sheath power cable
YJLW03XLPE insulated corrugated aluminium sheath or welding aluminium sheath PE sheath power cable
YJLW02-ZXLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PVC sheath power cable
YJLW03-ZXLPE insulated corrugated  aluminium sheath or welding aluminium sheath longitudinally water blocking PE sheath power cable
YJQ02XLPE insulated lead sheath PVC sheath power cable
YJQ03XLPE insulated lead sheath PVC sheath power cable
YJQ02-ZXLPE insulated lead sheath PVC sheath longitudinally water blocking power cable
YJQ03-ZXLPE lead insulated lead sheath PV sheath longitudinally water blocking power cable
  1.  Conductor structure , specifications , insulation thickness
Specifications Conductorcross-section (mm2)structureMinimum number of single wire in conductorMaximum of conductordirect-current resistance(Ω/km)Insulation nominal thickness
800Round conductor/Segmental conductor530.022134
1000Segmental conductor1700.017633
1200Segmental conductor1700.015133
1400Segmental conductor1700.012932
1600Segmental conductor1700.011332
1800Segmental conductor2650.010131
2000Segmental conductor2650.00931
2200Segmental conductor2650.008331
2500Segmental conductor2650.007331
7. Representation method of product
For example
A. Single-core copper conductor with rated voltage of 290/500 KV, nominal sectional area of 1200 mm2, so XLPE insulated corrugated aluminium sheath PVC sheath power cable will be represented as : YJLW02-290/500 KV - 1×1200 GB/T 22078.2-2008.
B. Single-core copper conductor with rated voltage of 290/500 KV , nominal sectional area of 2500 mm2, so XLPE insulated corrugated lead sheath PVC sheath longitudinally water blocking power cable  will be represented as : YJQ03-Z-290/500 KV- 1×2500 GB/T22078.2-2008.
High Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper ConductorHigh Voltage PVC or XLPE Insulated Power Cable 220kv Yjlw03 2500mm2 Pure Copper Conductor