China Exhaust Emission Tester Analyzer Measurement Car Exhaust Gas Analyser, Find details about China Exhaust Gas Analyzer, Automobile Exhaust Gas Analyzer from China Exhaust Emission Tester Analyzer Measurement Car Exhaust Gas Analyser
I.Main Features
The large screen liquid crystal display, ( Chinese or English ) menu;
The use of German imports of infrared detector, O2and NOX sensor, vibration resistance, good stability, high precision;
The measurement of CO, HC, CO2for O2, NOX, COcor, concentration and the lambda value, speed, temperature, flow, pressure;
With the single, double idle idle, general measuring function;
Vehicles capable of measuring gasoline, LPG, CNG, alcohol and diesel fuel;
According to the new standard and the United States BAR97standards development, in line with the ISO3930or OIMLR99 I level precision;
With the automatic zero adjustment, automatic cleaning, automatic temperature compensation, pressure compensation;
With the HC residue measurement, traffic monitoring, gas leak check;
The machine has self diagnostic function, fault when prompted, until the troubleshooting can continue measurement;
With speed, temperature measurement, built-in printer or digital (Analog ) interface network;
The license plate number input and 2000 groups of data storage, reference function, clock display;
II.Mani Technical
Measuring range:HC: 0~10000×10-6(ppm)vol,CO: 0~10×10-2(%)vol )
CO2: 0~20×10-2(%)vol, O2: 0~25×10-2(%)vol
NOx: 0~5000×10-6(ppm)vol,
R.M.P: 0~9999r.m.p OIL TEMP:0~150ºC
Lambda: 0.50~3.00 COcor:0~10×10-2(%)vol
Indicating error:HC±12×10-6(ppm)vol ( absolute error ) or±5% ( relative error )
CO±0.06×10-2(%)vol ( absolute error ) or±5% ( relative error )
CO2±0.5×10-2(%)vol ( absolute error ) or±5% ( relative error )
O2±0.1×10-2(%)vol ( absolute error ) or±5% ( relative error )
NOx±25×10-6 (ppm)vol ( absolute error ) or±4% ( relative error )
Stability:moment drift≤±3%
Repeatability ≤±2%
Resolution: HC:1×10-6(ppm)vol, CO: 0.01×10-2(%)vol,CO2: 0.1×10-2(%)vol,
O2: 0.01×10-2(%)vol, NOx: 1×10-6(ppm)vol, Lambda: 0.01,
R.P.M:10r.p.m, OIL TEMP:0.1ºC
Response time: 95% response is not more than 10 seconds
Preheating time: 8min ( preheating 3min emergency detection )
Output mode:Output mode can display, print gas concentration maximum value, average value, the minimum value of the license plate number, test time, date, speed, temperature and COcor value of lambda,, can interface with computer networking
And-use temperature | -5~50°C, Relative humidity: ≤90% |
Power | AC100~240V 50/60Hz or DC12V( Add power inverter) |
Power consumption | 40VA |
Dimension | 420 (L )×310(W)×170(H)mm |
Weight | 9kg |