Intelligent Automatic Wet Laser Particle Analyzer

China Intelligent Automatic Wet Laser Particle Analyzer, Find details about China Wet Laser Particle Size Test Machine, Wet Laser Particle Instrument from Intelligent Automatic Wet Laser Particle Analyzer

Model NO.
MAM8102-1250
Lens
Canon Lens
Laser
High-Quality Fiber Output High-Power Laser
Optical Path Calibration
Automatic Calibration
Ultrasound Frequency
40kHz
Trademark
Mayzum
Specification
980mm*410mm*450mm
Origin
China
Model NO.
MAM8102-1250
Lens
Canon Lens
Laser
High-Quality Fiber Output High-Power Laser
Optical Path Calibration
Automatic Calibration
Ultrasound Frequency
40kHz
Trademark
Mayzum
Specification
980mm*410mm*450mm
Origin
China
 
 Intelligent Automatic Wet Laser Particle Size Analyzer
 
MAM8102-1250

Intelligent Automatic Wet Laser Particle Analyzer


Introduction

MAM8102-1250 is the latest product developed by our company, and has won unanimous praise from customers since its listing. MAM8102-1250 adopts the most advanced Mie scattering principle and the convergent light Fourier transform optical path. The high-density probe and the full-scale seamless connection test method ensure the accuracy and repeatability of the test results. The unique wet circulation dispersion system ensures that there is no particle deposition phenomenon during the particle test, and no waste liquid accumulation phenomenon after the test drainage, which ensures the accuracy of the second test and makes the test result more realistic and reliable. At the same time, it adopts a pipe residue-free design. Ensure the accuracy of testing different samples. The superior optical path automatic proofreading system demonstrates the unique advantages of MAM8102-1250.

Stability and repeatability reach Malvern instrument standards!

 
Schematic diagram of the control system of  intelligent laser particle size analyzer:


Intelligent Automatic Wet Laser Particle Analyzer
 



Main performance characteristics


Advanced optical path design:

MAM8102-1250 adopts convergent light Fourier transform test technology to ensure that the maximum range is obtained at the shortest focal length, which effectively improves the resolution of the instrument; the unique high-density detection unit gives MAM8102-1250 super small particle test capability and high-density detection The unit enables MAM8102-1250 to have super-strong full-scale seamless test capability, and the high-profile version adopts a dual-optical path design.


Dustproof and shockproof design:

The entire instrument has a sealed design, which greatly increases the service life of internal components. The unique suspended structure can effectively avoid the interference of external vibration to the instrument, making the result test more stable and reliable.


Dual optical path and dual laser:

The MAM8102-1250 high-profile version adopts a dual optical path and multi-lens design. The main light uses a highly stable and long-life imported fiber semiconductor laser, and the auxiliary light uses a highly stable and long-life imported fiber semiconductor laser (λ=635nm, p>5mW).


Fully sealed fiber semiconductor laser:

It adopts a highly stable and long-life fully sealed imported fiber semiconductor laser, and its excellent stability allows it to have super test repeatability, with a lifespan of more than 30,000 hours.


Laser power monitoring and automatic adjustment:

Exclusive use of constant power laser, real-time detection of laser power and automatic adjustment function, effectively avoiding the problem of laser power attenuation caused by long-term use. At the same time, the constant current, constant voltage and high filter laser power supply is used to effectively extend the life of the laser, and the normal use reaches more than 30,000 hours.


Laser intelligent management system:

The first to increase the laser intelligent management system, the intelligent management system monitors the working status of the instrument in real time, once it receives the work command, the intelligent management system will instantly light up the laser, and the high-performance laser will reach a stable working state within 3 seconds. After the sample is tested, the intelligent management system will automatically turn off the laser, and the laser will not attenuate basically. In theory, it is not necessary to replace the laser for life.


Automatic proofreading in X and Y directions of optical path:

MAM8102-1250 exclusively adopts the technology of combining mechanical center and optical center, the optical path is automatically adjusted and positioned more accurately, reaching the micron level; at the same time, the optical path adjustment speed is faster and the adjustment can be completed in 15 seconds.


Unique microcirculation system:

The entire dispersing circulation system has been optimized design, the dispersing medium can be circulated test if the dispersing medium is larger than 180ml, and it can really achieve the micro circulation test; all the joints adopt the quick plug and quick screw design, all the pipes can be replaced in a short time; the optimized design guarantees drainage There is no waste left, which ensures the accuracy of the next test result.


Ultra-wide range:

The range of MAM8102-1250 reaches 0.01μm~1250μm.


Ultrasonic anti-dry burn:

MAM8102-1250 is equipped with 100W high-power ultrasound, and it also has the function of anti-dry-burning ultrasound.


Misoperation protection:

MAM8102-1250 has a self-protection function, and does not respond to some misoperations that may damage the instrument, which greatly reduces the damage caused by human misoperation.


Dew point measurement:

Fogging on the sample window will affect the accuracy of the measurement. Such test results have no practical significance. MAM8102-1250 is equipped with a fogging point measurement system. Once fogging, the software will automatically prompt.


No-drain bubble design:

The new design prevents bubbles from entering the test sample window during the entire test process, avoiding bubble interference (we exclusively own the technology of avoiding bubbles).


Sample residue-free design:

The instrument piping and drainage structure have been optimized. There is no liquid residue in the instrument piping and circulating pump to avoid the impact on the next test data; the dry test is also designed with no residue.


Quick change device for sample window:

The newly designed sample window quick-change device makes the sample window replacement more convenient and quick (the sample window can be disassembled and assembled in 20 seconds).


Software interface (Chinese and English versions are optional)

Intelligent Automatic Wet Laser Particle Analyzer

Optical path automatic centering function diagram

Intelligent Automatic Wet Laser Particle Analyzer



The main technical parameters:
 
 Intelligent Automatic Wet Laser Particle Size Analyzer
 
ModelMAM8102-1250
Executive standardISO 13320-1:1999;GB/T19077.1-2008
Test range0.01μm -1250μm
Detector Channel112
Accuracy<1% (National standard sample D50 value)
Repeatability error<0.5% (National standard sample D50 value)
No-drain bubble designWith no bubble discharge design, no bubble interference data is more accurate
Misoperation protectionThe instrument has a self-protection function for misoperations, and the instrument does not respond to misoperations
LensCanon lens
Laser parametersHigh-quality fiber output high-power laser λ= 650nm, p>10mW. Service life> 30000 hours
Laser Intelligent Management SystemReal-time monitoring of the working state of the instrument, once receiving the work command, the intelligent management system will instantly light up the laser, and the high-performance laser will reach a stable working state within 3 seconds
Optical path calibrationAutomatic calibration


Built-in dispersion method
Ultrasoundfrequency: f=40KHz, power: p=80W, time: adjustable at will; with ultrasonic anti-drying
Circulation and stirringIntegrated design of circulating stirring, speed: 100-33950rpm, adjustable speed
Circulation rateCirculating rated flow: 0-10L/min adjustable Rated power: 25W
Sample cellSelf-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally
Dustproof and shockproof designThe whole machine adopts dustproof and shockproof design
Micro sampling (optional)The instrument can be equipped with a micro-automatic test device, 10ml can be cycled test (optional)
Anti-corrosion design (optional)It can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (such as acetone, phenol, n-hexane and all organic solvents).















Software function

Analysis mode
Including free distribution, R-R distribution and lognormal distribution, classification statistics mode by item, etc., to meet the different requirements of different industries for the statistical methods of the particle size of the tested samples
Statistical methodsVolume distribution and quantity distribution to meet the different statistical methods of particle size distribution in different industries


Statistical comparison
It can perform statistical comparison and analysis for multiple test results, which can obviously compare the differences of different batches of samples, samples before and after processing, and test results at different times, which has strong practical significance for the quality control of industrial raw materials.
DIYUser-defined data to be displayed, calculate the percentage according to the particle size, and find the particle size according to the percentage
Display templateCalculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Diameter, consistency, interval accumulation, etc.

Test report
Test report can be exported to Word, Excel, picture (Bmp) and text (Text) and other forms of documents, satisfying to view test reports and quoting test results in scientific research articles on any occasion
Multi-language supportChinese and English language interfaces are supported, and other language interfaces can be embedded according to user requirements.
Intelligent operation modeReally automatic operation without human intervention, no human factors interfere, you only need to add the sample to be tested according to the prompt, and the repeatability of the test results is better.
Shading detectionThe instrument has a unique real-time detection function of shading to ensure that the amount of sample added is more accurate
Operation modeOne-button automatic software operation mode
Test speed<1min/time (excluding sample dispersion time)
Volume980mm*410mm*450mm
Weight35Kg
 

Test report:
 
 
 
Intelligent Automatic Wet Laser Particle Analyzer
 
 
Chinese and English versions are optional
 
Company Profile:

 
Intelligent Automatic Wet Laser Particle Analyzer