China Digital Clamp Meter 6000 Counts Auto-Ranging Multimeter with AC/DC Voltage; Current, Resistance, Capacitance, Frequency, Find details about China Three Phase Power Meter Clamp, Earth Resistance Meter Clamp from Digital Clamp Meter 6000 Counts Auto-Ranging Multimeter with AC/DC Voltage; Current, Resistance, Capacitance, Frequency
specifications | range | accuracy | ||
HT208A | HT208B | HT208D | ||
DC Voltage | 6V/60V/600V/1000V | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
AC Voltage | 6V/60V/600V/750V | ±(1.2%+3) | ±(1.2%+3) | ±(1.2%+3) |
DC Current | 60A/600A/1000A | ±(3.0%+5) | ||
AC Current | 60A/600A/1000A | ±(3.0%+5) | ±(3.0%+5) | ±(3.0%+5) |
Resistance | 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
Capacitance | 60nF/600nF/6uF/60uF/600uF/6mF/60mF | ±(4.0%+3) | ±(4.0%+3) | ±(4.0%+3) |
100mF | ±(5.0%+5) | ±(5.0%+5) | ±(5.0%+5) | |
Frequency | 10Hz/100Hz/1kHz/10kHz/ 100kHz/1MHz/10MHz | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) ±(1.0%+2) |
Duty | 1%~99% | ±(1.0%+2) | ±(1.0%+2) | ±(1.0%+3) |
Temperature(ºC/°F) | -40ºC~1000ºC | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
-40°F~1832°F | ±(1.0%+3) | ±(1.0%+3) | ||
Counters | 6000 | 6000 | 6000 | |
Auto/manual range | √ | √ | √ | |
Bargraph | √ | √ | ||
NCV (LED and Buzz) | √ | √ | √ | |
Diode | √ | √ | √ | |
Continuity (LED and Buzz) | √ | √ | √ | |
MAX/MIN hold | √ | √ | √ | |
Data hold | √ | √ | √ | |
True RMS | √ | √ | √ | |
AC bandwidth | 1KHZ | 1KHZ | 1KHZ | |
Low battery indication | √ | √ | √ | |
Auto power off | √ | √ | √ | |
Double color backlight | √ | √ | √ | |
Flashlight | √ | √ | √ | |
LPF | √ | √ | ||
V-Loz | √ | √ |