Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2)

China Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2), Find details about China Fan Coil Unit, Fan Coil from Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2)

Model NO.
EST200C2
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Fan Coil Type
Ceiling Cassette Fan Coil Unit
Pipe System
Two Pipe and Four Pipe System
Air Outlet
1 Way or 4 Way or Multi Way
Water Inlet/Outlet Pipe Size
Zg 3/4"
Trademark
Eurostars
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
84159010
Model NO.
EST200C2
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Fan Coil Type
Ceiling Cassette Fan Coil Unit
Pipe System
Two Pipe and Four Pipe System
Air Outlet
1 Way or 4 Way or Multi Way
Water Inlet/Outlet Pipe Size
Zg 3/4"
Trademark
Eurostars
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
84159010
Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2)

Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit

1. Ceiling cassette fan coil unit features:
(1)Ultra-low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Easy installation and oeration; (5)Ingenious design.

In central air conditioner system, Eurostars ceiling cassette fan coil unit continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Ceiling floor fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Ceiling cassette floor fan coil unit nomenclature

ES  T   600    C2   K4   Q    0    A   O
1    2      3       4     5     6    7    8    9
1: ES Eurostars
2 :T Terminal series
3 :600 Rated air flow: CFM
4 :C2 Cassette type and the number of tube system
5 :K4 Air outlet: K4-Four way; K1-One way; K2-Two way; K-Multi way                                    

6 :Q Drainage way:
     Q-Forced drainage, electronic control;   V-Forced drainage, electronic control, built-in water valve
     S-Natural drainage, no control;                 H-Natural drainage, electronic control
7: 0 Inbuilt electrical heating: 0-None;  1-Electrical heating power 1.0KW (so on and so forth)
8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
9 :O Sales region: O-Other regions;  C-Mainland China


3.Ceiling cassette fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com

Cassette Fan Coil Unit (4-way  2 pipe system)
Model   EST~200C2300C2400C2500C2600C2800C21000C21200C21400C2
Power supply220V,50Hz,1Ph
Air flow
 (m3/h)
H34051068085010201360170020402380
M2803805156607651040128015501800
L18026034043053071086010501280
Static pressurePa000000000
Cooling capacityTHHW18002700360045005400720090001080012600
BTU/h6142921212283153541842524566307083685042991
SHW131119712700318441965362670780729070
BTU/h447367259212108641431718295228842754230947
THMW1500246030003715442364357848929610500
BTU/h5118839410236126761509121956267773171835826
SHW99415551995242630414236539366037190
BTU/h33925306680782781037614453184012252924532
THLW139120572479292137935604722385348900
BTU/h47467018845899661294519121246452911830367
SHW82312001530182623733284441652485500
BTU/h2808409452206230809711205150671790618766
Heating capacityHW2700405054006750810010800135001620018900
BTU/h9215 13823 18430 23038 27645 36860 46076 55291 64506 
MW194927703938490256947924104731299713900
BTU/h6652 9454 13440 16731 19434 27045 35744 44359 47441 
LW129717742779350538765421699286459700
BTU/h4427 6055 9485 11963 13229 18502 23864 29505 33106 
 Noise HdB(A)373941434546485051
Power inputHW3752627696134152189228
Water flow Hm3/h0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85 2.16 
 Water resistance kPa11.811.822.42729.629.635.435.440
Pipe Inlet water pipeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
Outlet water pipeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
Coiltype Hydrophilic aluminum fin arounds high efficient copper pipe 
Working pressureMPa1.6
Condensation water pipemm¢26¢26¢26¢26¢26¢26¢26¢26¢26
Dimension  Natural Drainage L×W×H     mm590*590*420752*752*443822*822*405822*822*443
Forced Drainage590*590*270752*752*293822*822*260822*822*293
Panel650*650*45850*850*45950*950*45
N.W.  Natural Drainage kg191920232325282829
Forced Drainage 191920262628313132
Panel2.24.56

Cassette Fan Coil Unit(4-way  4 pipe system)
Model   EST~200C4300C4400C4500C4600C4800C41000C41200C41400C4
Power supply220V,50Hz,1Ph
Air flow
 (m3/h)
H34051068085010201360170020402380
M2803805156607651040128015501800
L18026034043053071086010501280
Static pressure
Pa000000000
Cooling capacityTHHW135020302700338040505400675081009450
BTU/h460669269212115331381918425230312763732243
SHW101015202080245032304130516062206989
BTU/h34465186709783591102114092176062122323846
THMW113018502250279033204830589069707873
BTU/h38566312767795191132816480200972378226863
SHW77012001540187023403260415050805532
BTU/h2627409452546380798411123141601733318875
THLW104015401860219028404200542064006674
BTU/h3548525463467472969014330184932183722772
SHW6309201180141018302530340040404234
BTU/h215031394026481162448632116011378414446
Heating capacityHW108016202160270032404320540064807560
BTU/h3686 5529 7372 9215 11058 14744 18430 22116 25802 
MW78011081575196122783170418951995560
BTU/h2662 3782 5375 6693 7775 10819 14297 17744 18976 
LW5197101112140215502168279734583880
BTU/h1771 2423 3795 4785 5290 7399 9546 11802 13242 
NoiseHdB(A)373941434546485051
Power inputHW3752627696134152189228
Water flow volumeCooling TubeHm3/h0.23 0.35 0.46 0.58 0.69 0.93 1.16 1.39 1.60 
Heating Tube0.09 0.14 0.19 0.23 0.28 0.37 0.46 0.56 0.70 
Water resistance CoolingHkPa8.268.2615.6818.920.7220.7224.7824.7840
Heating3.543.546.728.18.888.8810.6210.6216
Inlet water pipeCooling tube/
Heating tube
ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
Outlet water pipeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
Coiltype Hydrophilic aluminum fin arounds high efficient copper pipe 
Working pressureMPa1.6
Condensation water pipemm¢26¢26¢26¢26¢26¢26¢26¢26¢26
Dimension  Natural Drainage unitL×W×H     mm590*590*420752*752*443822*822*405822*822*443
Forced Drainage unit590*590*270752*752*293822*822*260822*822*293
Panel650*650*45850*850*45950*950*45
N.W.  Natural Drainage unitkg191920232325282829
Forced Drainage unit191920262628313132
Panel2.24.56

Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature  60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

4. Eurostars Ceiling cassette fan coil unit photos viewing
Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2)
4. Eurostars Ceiling cassette fan coil unit dimension 
Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2)
5.Ceiling cassette fan coil unit installation illustration

Eurostars Top Quality Cassette Fan Coil with Drain Pump (EST200C2)