Air-Cooled Condensing Unit with Split V Type Condensers

China Air-Cooled Condensing Unit with Split V Type Condensers, Find details about China Condensing Unit, Blast Freezer from Air-Cooled Condensing Unit with Split V Type Condensers

Model NO.
ESGA-140NJR2BY
Cooling Mode
Air Cooling or Air Cooled
OEM/ODM
Available
Condenser Type
Aluminum Fin Copper Tube(Optional)
Compressor Brand
Germany Bitzer
Lifetime
More Than 20 Years
Optional
Evaporative Condenser
Cold Room Panel
Available
Refrigerant Gas
R404A/R507A
Structure
Assembled
Evaporative-Cooled Condensers
Optional
Overseas Installation
Available
Compressor Qty
1 or 2 or 3 or 4 or More
Trademark
ESACIR
Transport Package
Standard Export Package
Specification
CE
Origin
Guangdong, China
HS Code
8418692090
Model NO.
ESGA-140NJR2BY
Cooling Mode
Air Cooling or Air Cooled
OEM/ODM
Available
Condenser Type
Aluminum Fin Copper Tube(Optional)
Compressor Brand
Germany Bitzer
Lifetime
More Than 20 Years
Optional
Evaporative Condenser
Cold Room Panel
Available
Refrigerant Gas
R404A/R507A
Structure
Assembled
Evaporative-Cooled Condensers
Optional
Overseas Installation
Available
Compressor Qty
1 or 2 or 3 or 4 or More
Trademark
ESACIR
Transport Package
Standard Export Package
Specification
CE
Origin
Guangdong, China
HS Code
8418692090
1. Bitzer Semi-hermetic screw compressor racks condensing unit refrigeration unit introduction.
Bitzer compressor racks condensing unit is with original Bitzer semi-hermetic compressor. Applicable for medium and low temperature. Beautiful design, rational construction and convenient installation made the units widely used in medical, agricultural, chemical industry, and all other filed where cold storage is needed.

2. Bitzer Semi-hermetic screw compressor racks condensing unit refrigeration unit features and Technical data:
1) Adopt world famous brand semi-hermetic Bitzer compressors, with high reliability, less vibration and low noise; 
2) Adopt beautiful structure, attractive appearance, compact structure, easy installation;
3) High efficiency and low noise Condenser fan
4)Adopt copper tube aluminum fin condenser or shell and tube condenser, with more face area, high heat exchange efficiency and long service life.
5) Can meet medium and low temperature requires.


**AIR COOLING
ITEMModelCooling Capa. (KW)Comp.Power Input(KW)Cooling Capa. (KW)Comp.Power Input(KW)Compressor (R404a)Temp. Range
(cold room)
ModelQuantity
EvaT=0ºC;50HZEvaT=-10ºC;50HZ
1ESGA-50NJBY99.138.264.336.5CSH6553-50Y1 -5ºC~5ºC
2ESGA-60NJBY124.547.780.945.4CSH6563-60Y1 -5ºC~5ºC
3ESGA-70NJBY143.853.59351.3CSH7553-70Y1 -5ºC~5ºC
4ESGA-80NJBY162.760.2105.556.6CSH7563-80Y1 -5ºC~5ºC
5ESGA-90NJBY188.969.4124.366.2CSH7573-90Y1 -5ºC~5ºC
6ESGA-100NJR2BY198.276.4128.673CSH6553-50Y2 -5ºC~5ºC
7ESGA-120NJR2BY24995.4161.890.8CSH6563-60Y2 -5ºC~5ºC
8ESGA-140NJR2BY287.6107186102.6CSH7553-70Y2 -5ºC~5ºC
9ESGA-160NJR2BY325.4120.4211113.2CSH7563-80Y2 -5ºC~5ºC
10ESGA-180NJR2BY377.8138.8248.6132.4CSH7573-90Y2 -5ºC~5ºC
11ESGA-150NJR3BY297.3114.6192.9109.5CSH6553-50Y3 -5ºC~5ºC
12ESGA-180NJR3BY373.5143.1242.7136.2CSH6563-60Y3 -5ºC~5ºC
13ESGA-210NJR3BY431.4160.5279153.9CSH7553-70Y3 -5ºC~5ºC
14ESGA-240NJR3BY488.1180.6316.5169.8CSH7563-80Y3 -5ºC~5ºC
15ESGA-270NJR3BY566.7208.2372.9198.6CSH7573-90Y3 -5ºC~5ºC
For more information please contact us.
Air-Cooled Condensing Unit with Split V Type Condensers

3. Bitzer Semi-hermetic screw compressor racks condensing unit refrigeration unit Main Components
Key components:
Middle temperature:
1. CSH screw compressor  2. External oil separator 3. Water condenser/Liquid receiver 4. Liquid line filter 5.Sight glass
6. Liquid injection 7. High and low pressure protector 8. High pressure controller 9. Pressure gauge 10. Suction filter
11. Oil line filter 12. Oil line solenoid valve 13. Oil level protector 14. Unit control(PLC+ touch screen)

Air-Cooled Condensing Unit with Split V Type Condensers

4. Condensing unit series:
Air-Cooled Condensing Unit with Split V Type Condensers

A) Wall/Roof mounted monoblock condensing unit/ refrigeration unit

B) Emerson Copeland compressor condensing unit / refrigeration unit(box type structure)
C) Bitzer piston compressor condensing unit/ refrigeration unit(box type structure)
D) Bitzer piston compressor condensing unit/ refrigeration unit(open type structure)
E) Bitzer 2-stage compressor condensing unit / refrigeration unit
F) Bitzer Semi-hermetic piston compressor racks condensing unit / refrigeration unit
G) Bitzer Semi-hermetic screw compressor racks condensing unit / refrigeration unit
H) Hanbell Semi-hermetic screw compressor racks condensing unit / refrigeration unit
I) Cold room cold storage indoor evaporator


5.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com
Website 2: http://eurostarschiller.en.made-in-china.com
 
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
 


Air-Cooled Condensing Unit with Split V Type Condensers
Air-Cooled Condensing Unit with Split V Type Condensers

6.FAQ
Q:How to identify the original new Bitzer compressor?
If the Bitzer compressor price is 40% lower, it may probably not original new compressor. Also, each Bitzer compressor have one security code, you could check it on Bitzer website. 

Q:How to distinguish between the original new and fake Bitzer compressor?
Each compressor has a unique nameplate with QR code. Use the cellphone to scan the code, the result will show on the phone from Bitzer company systems. Any phone can do. Original new, result is successful and fake compressor fail. 

Q:Where are Bitzer compressor production bases located?
Beijing China, America, Germany, Egypt and so on. They follow the German headquarters strict quality control system. We purchase Bitzer compressor from Bitzer factory in Beijing. 

Q:How many kinds of Bitzer compressors?
Semi-hermetic(ECOLINE series),Two stages semi-hermetic, Semi-hermetic screw compressor, Hermetic screw compressor.

Q:What is the Bizter lifetime?
Normally 8 years at least. But need maintenance to ensure high efficiency.

7. Customers Visit
Air-Cooled Condensing Unit with Split V Type Condensers

Air-Cooled Condensing Unit with Split V Type Condensers
8. Product package and deliver:
A:For cold room machine:Standard package f with plywood, the unit can be well protected, it is with pallet on the bottom for easy transportation., the unit can be well protected ,suitable for container shipment. 
B:For cold room panel:Plastic film for panel, Each panel is well wrapped with plastic film respectively, the corner is protected with brown paper. 
Air-Cooled Condensing Unit with Split V Type Condensers

9. Installation instructions and project photo
--Installation
a) The unit can be lifted by fork vehicle or sling. If the sling is used, it should not touch any pipes or electrical components in operation. 
b) The unit must be installed keep in level in an environment with good air flow, far away from heat resources, places of high temperature and high humidity. If the unit is installed in the open air, a shelter is required to keep the unit from direct sun shine and raining. Appropriate space shall be left for maintenance. 
c) The room for the unit should be good for the air flowing, the temperature of the room must not be higher than 40ºC.
d) For the water cooled system, adequate cooling tower, pumps and pipes, water flowing switch should be chosen. In case too small water or no water, the system can start protection automatically.

--Pipe connection
a) Do not expose the mouth of the compressor and filtering - drier to the open air.
b) The level part of the suction pipe should be inclined an angle to the compressor; the level part of the discharging pipe should be inclined to condenser.
c) Fix the pipe to decrease the sound and vibration level.
d) In operation of refrigerant pipes, neutral gas of low pressure is to be filled to prevent the pipes from inner oxidation. Dry nitrogen is recommended as the protection gas.    
e) Clean the refrigeration system with dry nitrogen; keep the system free of dirt, oxid and foreign matters. 
f) For the main suction line a U shaped pipe part for oil returning must be set below the compressor; an upside down U shaped pipe part must be set for each 4 meters in case the unit is fixed higher than the evaporator. The suction line need be wrapped with heat insulation material to keep it from frosting and overheating.