China Bitzer Compressor Air to Water Heat Pump Water Heater, Find details and Price about China Heat Pump, Air to Water Heat Pump from Bitzer Compressor Air to Water Heat Pump Water Heater
Air Cooled Chiller Unit Heat Pump (Screw Type Compressor-one compressor) | |||||||||
Model ESGA- | 30SHTN | 40SHTN | 55SHTN | 65SHTN | 75SHTN | 85SHTN | 90SHTN | ||
Rated Cooling Capacity | Cooling Capacity (KW) | 111 | 161 | 215 | 254 | 294 | 321 | 346 | |
Cooling Capacity (USRT) | 31.57 | 45.79 | 61.15 | 72.24 | 83.62 | 91.30 | 98.41 | ||
Comp. Input Power (KW) | 34.6 | 48.2 | 63.8 | 70.5 | 82.4 | 90.2 | 98.9 | ||
Rated Heating Capacity | Heating Capacity (KW) | 122 | 174 | 232 | 269 | 311 | 341 | 369 | |
Heating Capacity (USRT) | 34.70 | 49.49 | 65.98 | 76.51 | 88.45 | 96.99 | 104.95 | ||
Comp. Input Power (KW) | 34.1 | 47.4 | 62.8 | 69.2 | 80.8 | 88.4 | 97.2 | ||
Refrigerant | R407C | ||||||||
Power Supply | 3φ-380V/50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Reserved water flow protection interface. | ||||||||
Number of Refrigeration Circuit | 1 | ||||||||
Capacity Control (%) | 0, 66, 100 | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | ||
Air Cooled Heat Exchanger | Ripple Aluminum Fins Around Copper Pipe | ||||||||
Water Cooled Heat Exchanger | Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" | |
Water Side Max Pressure (MPa) | 1 | ||||||||
Chilled Water Flow(m3/h) | 19.09 | 27.69 | 36.98 | 43.69 | 50.57 | 55.21 | 59.51 | ||
Water Pressure Drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | ||
Flow of Hot Water(m3/h) | 20.98 | 29.93 | 39.90 | 46.27 | 53.49 | 58.65 | 63.47 | ||
Axial Fan | Air Flow×1000m3/h | 56.8 | 80.4 | 85.2 | 120.6 | 120.6 | 160.8 | 160.8 | |
Power×Qty (KW) | 1.2×4 | 2.0×4 | 1.2×8 | 1.2×8 | 1.2×8 | 2.0×8 | 2.0×8 |
Air Cooled Chiller Unit Heat Pump (Screw Type Compressor-two compressor) | |||||||||
Model ESGA- | 100DHTN | 110DHTN | 130DHTN | 140DHTN | 150DHTN | 165DHTN | 180DHTN | ||
Rated Cooling Capacity | Cooling Capacity (KW) | 392 | 439 | 509 | 537 | 588 | 642 | 693 | |
Cooling Capacity (USRT) | 111.49 | 124.86 | 144.77 | 152.73 | 167.24 | 182.59 | 197.10 | ||
Comp. Input Power (KW) | 116.4 | 127.6 | 141.0 | 148.2 | 164.8 | 180.4 | 197.8 | ||
Rated Heating Capacity | Heating Capacity (KW) | 424 | 464 | 538 | 568 | 624 | 682 | 740 | |
Heating Capacity (USRT) | 120.59 | 131.97 | 153.01 | 161.55 | 177.47 | 193.97 | 210.47 | ||
Comp. Input Power (KW) | 114.4 | 125.6 | 138.3 | 145.4 | 161.7 | 176.9 | 194.4 | ||
Refrigerant | R407C | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Reserved water flow protection interface. | ||||||||
Number of Refrigeration Circuit | 2 | ||||||||
Capacity Control (%) | 0, 25, 37.5, 50, 62.5, 75, 87.5, 100 | ||||||||
Refrigerant Charge (Kg) | 114 | 122 | 146 | 150 | 164 | 178 | 196 | ||
Air Cooled Heat Exchanger | Ripple Aluminum Fins Around Copper Pipe | ||||||||
Water Cooled Heat Exchanger | Dia.of Pipe (inch) | 5" | 5" | 3"×2 | 3"×2 | 4"×2 | 4"×2 | 4"×2 | |
Water Side Max Pressure (MPa) | 1 | ||||||||
Chilled Water Flow(m3/h) | 67.42 | 75.51 | 87.55 | 92.36 | 101.14 | 110.42 | 119.20 | ||
Water Pressure Drop (kPa) | 42 | 54 | 44 | 52 | 54 | 55 | 65 | ||
Flow of Hot Water(m3/h) | 72.93 | 79.81 | 92.54 | 97.70 | 107.33 | 117.30 | 127.28 | ||
Axial Fan | Air Flow×1000m3/h | 160.8 | 160.8 | 172.8 | 241.2 | 230.4 | 321.6 | 321.6 | |
Power×Qty (KW) | 1.2×12 | 1.2×12 | 2.0×12 | 2.0×12 | 1.2×16 | 2.0×16 | 2.0×16 |