Eurostars Screw Chiller Heat Pump

China Eurostars Screw Chiller Heat Pump, Find details and Price about China Air Source Heat Pump, Air to Water Heat Pump from Eurostars Screw Chiller Heat Pump

Model NO.
ESGA-95SHTS
Compresor 1
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson/Danfoss
Heat Pump Dry Filter
Danfoss
Compressor 2
Germany Bitzer
Trademark
Eurostars
Specification
CE
Origin
Guangdong, Prc
HS Code
8418692090
Model NO.
ESGA-95SHTS
Compresor 1
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson/Danfoss
Heat Pump Dry Filter
Danfoss
Compressor 2
Germany Bitzer
Trademark
Eurostars
Specification
CE
Origin
Guangdong, Prc
HS Code
8418692090
1.Brief introduction-Eurostars air cooled air source heat pump
a)Ambient temp range:-5~43C(-25C~43C)
b)Intellectualized control system and Low Noise
c)High Efficient and Energy Saving
d)Easy Operation and Installation
e)Compact Exterior
f)High quality
g)Competitive price

2.Unit Features-Eurostars air cooled air source heat pump

1).Heating capacity ranged from 130Kw to 790 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc
6). Strong unit base frame ensured the equipment stable operation
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.


3.Technical parameter-air cooled air source heat pump
Please ask salesman for detailed complete data or visit our website.

Model     ESGA-30SHTS45SHTS60SHTS70SHTS80SHTS85SHTS95SHTS
Rated Cooling CapacityCooling Capacity (KW)119170228269310337369
Cooling Capacity (USRT)33.8548.3564.8576.5188.1795.85104.95
Comp. Input Power (KW)34.747.763.271.282.489.999.9
Rated Heating CapacityHeating Capacity (KW)130183246285330357395
Heating Capacity (USRT)36.9752.0569.9781.0693.86101.54112.34
Comp. Input Power (KW)32.644.859.667.077.684.694.1
RefrigerantR22
Power Supply3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
Air Cooled Heat ExchangerRipple Aluminum Fins Around Copper Pipe
Water Cooled
Heat Exchanger
Dia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)20.4729.2439.2246.2753.3257.9663.47
Water Pressure Drop (kPa)28334855616466
Flow of Hot Water(m3/h)22.3631.4842.3149.0256.7661.4067.94
Axial FanAir Flow×1000m3/h56.880.485.2120.6120.6160.8160.8
Power×Qty (KW)1.2×42.0×41.2×81.2×81.2×82.0×82.0×8

Model     ESGA-110DHTS120DHTS140DHTS150DHTS160DHTS175DHTS190DHTS
Rated Cooling CapacityCooling Capacity (KW)415456537568620672740
Cooling Capacity (USRT)118.03129.69152.73161.55176.34191.13210.47
Comp. Input Power (KW)116.2126.4142.4149.8164.8179.8199.8
Rated Heating CapacityHeating Capacity (KW)447490570602659715789
Heating Capacity (USRT)127.13139.36162.12171.22187.43203.36224.40
Comp. Input Power (KW)109.3119.1134.0141.0155.2169.3188.3
RefrigerantR22
Power Supply3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)114122146150164178196
Air Cooled Heat ExchangerRipple Aluminum Fins Around Copper Pipe
Water Cooled
Heat Exchanger
Dia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)71.3878.4392.3697.70106.64115.58127.28
Water Pressure Drop (kPa)42544452545565
Flow of Hot Water(m3/h)76.8884.2898.04103.54113.35122.98135.71
Axial FanAir Flow×1000m3/h160.8160.8172.8241.2230.4321.6321.6
Power×Qty (KW)1.2×121.2×122.0×122.0×121.2×162.0×162.0×16

1. Rated Cooling Capacity Based on: DB Temperature 35ºC/WB Temperature 24ºC;Chilled water in/outlet temp. 12ºC/7ºC,  Fouling factor: 0.088.°C/KW.
2. Rated Cooling Capacity Based on: DB Temperature 7ºC/WB Temperature 6ºC;Hot water in/outlet temp. 40ºC/45ºC;  Hot water range: 45ºC~50ºC;

4.Quotation Remarks-air cooled air source heat pump
1.)Packing: Standard export package
2.)Delivery Day: 35 working days after deposit is confirmed
3.)Delivery term: CIF,FOB or CNF EX-Work are welcomed
4.)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
5.)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
6.)Validity: 20 days
7.)Payment currency: USD