China Runningway RF275 Oil Free Screw Air Compressor for Textile Industry, Find details about China Oil Free Screw Compressor, Oil Free Air Compressor from Runningway RF275 Oil Free Screw Air Compressor for Textile Industry
With CE and Class 0 certification, the Runningway dry rotary screw oil-free air compressor can provide you with 100% oil-free air and ensure the safety of your manufacturing line. Power ranges from 37 to 315 kilowatts.
Runningway fixed speed dry oil-free screw air compressor can provide oil-free air for a long time. Can provide you with a steady supply of air.
The Runningway VSD dry oil-free screw air compressor may provide variable frequency air to a system. Saving money allows you to meet your various air capacity requirements. The air capacity ranges between 2.6 and 51.5 m3/min.
Model | Maximum Working Pressure | Capacity(FAD)* | Installed Motor Power | Cooling Method | Noise Level | Air Outlet Pipe Diameter | Dimension | Weight | |||||
50hz | |||||||||||||
bar(g) | psig | m3/min | cfm | kw | hp | dB(A) | L | W | H | kg | |||
RF37-7A(W) | 7 | 102 | 6.5 | 229.5 | 37 | 50 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2000 | |||||||
RF37-8A(W) | 8 | 116 | 6.4 | 226 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2000 | |||||||
RF37-10A(W) | 10 | 145 | 6.3 | 222.4 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2000 | |||||||
RF45-7A(W) | 7 | 102 | 7.7 | 271.8 | 45 | 60 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF45-8A(W) | 8 | 116 | 6.5 | 229.5 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF45-10A(W) | 10 | 145 | 6.8 | 240.1 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF55-7A(W) | 7 | 102 | 9.6 | 339 | 55 | 75 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2000 | |||||||
RF55-8A(W) | 8 | 116 | 8.8 | 310.7 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2000 | |||||||
RF55-10A(W) | 10 | 145 | 7.7 | 271.9 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2000 | |||||||
RF75-7A(W) | 7 | 102 | 13.5 | 476.7 | 75 | 100 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF75-8A(W) | 8 | 116 | 13.3 | 469.6 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF75-10A(W) | 10 | 145 | 12.1 | 427.3 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF90-7A(W) | 7 | 102 | 16.2 | 572 | 90 | 120 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF90-8A(W) | 8 | 116 | 15.6 | 550.9 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF90-10A(W) | 10 | 145 | 14.2 | 501.4 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 | ||
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 | |||||||
RF110-7A(W) | 7 | 102 | 19.5 | 688.6 | 110 | 150 | Air Cooling | 69 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2700 | |||||||
RF110-8A(W) | 8 | 116 | 19.2 | 678 | Air Cooling | 69 | DN80 | 4050 | 1650 | 2000 | 3700 | ||
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2700 | |||||||
RF110-10A(W) | 10 | 145 | 17.5 | 618 | Air Cooling | 69 | DN80 | 4050 | 1650 | 2000 | 3700 | ||
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2700 | |||||||
RF132-7A(W) | 7 | 102 | 23.5 | 829.8 | 132 | 175 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2800 | |||||||
RF132-8A(W) | 8 | 116 | 22.8 | 805.1 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3700 | ||
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2800 | |||||||
RF132-10A(W) | 10 | 145 | 20.5 | 723.9 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3700 | ||
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2800 | |||||||
RF145-7A(W) | 7 | 102 | 23.9 | 844 | 145 | 195 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3800 |
Water Cooling | 68 | DN80 | 2550 | 1650 | 2000 | 2900 | |||||||
RF145-8A(W) | 8 | 116 | 22.1 | 780.4 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3800 | ||
Water Cooling | 68 | DN80 | 2550 | 1650 | 2000 | 2900 | |||||||
RF145-10A(W) | 10 | 145 | 20.5 | 723.9 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3800 | ||
Water Cooling | 68 | DN80 | 2550 | 1650 | 2000 | 2900 | |||||||
RF160-7A(W) | 7 | 102 | 28.5 | 1006.4 | 160 | 215 | Air Cooling | 75 | DN80 | 5040 | 1650 | 2100 | 5300 |
Water Cooling | 67 | DN80 | 3100 | 1650 | 2000 | 2900 | |||||||
RF160-8A(W) | 8 | 116 | 26.4 | 932.3 | Air Cooling | 75 | DN80 | 5040 | 1650 | 2100 | 5300 | ||
Water Cooling | 67 | DN80 | 3100 | 1650 | 2000 | 2900 | |||||||
RF160-10A(W) | 10 | 145 | 24.5 | 865.2 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5300 | ||
Water Cooling | 67 | DN80 | 3100 | 1650 | 2000 | 2900 | |||||||
RF200-7A(W) | 7 | 102 | 36.1 | 1274.8 | 200 | 270 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5400 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4000 | |||||||
RF200-8A(W) | 8 | 116 | 33.9 | 1197.1 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5400 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4000 | |||||||
RF200-10A(W) | 10 | 145 | 30.8 | 1087.6 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5400 | ||
Water Cooling | 67 | DN80 | 3100 | 1650 | 2000 | 4000 | |||||||
RF250-7A(W) | 7 | 102 | 45.2 | 1596.2 | 250 | 350 | Air Cooling | 75 | DN80 | 5040 | 1650 | 2100 | 5500 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4100 | |||||||
RF250-8A(W) | 8 | 116 | 43.4 | 1532.6 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5500 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4100 | |||||||
RF250-10A(W) | 10 | 145 | 38.8 | 1370.2 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5500 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4100 | |||||||
RF275-7A(W) | 7 | 102 | 46.8 | 1652.7 | 275 | 370 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5500 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4200 | |||||||
RF275-8A(W) | 8 | 116 | 43.5 | 1536.1 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5500 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4200 | |||||||
RF275-10A(W) | 10 | 145 | 41.5 | 1465.5 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5500 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4200 | |||||||
RF315-7A(W) | 7 | 102 | 53 | 1871.6 | 315 | 420 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4400 | |||||||
RF315-8A(W) | 8 | 116 | 51.5 | 1818.7 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4400 | |||||||
RF315-10A(W) | 10 | 145 | 49.5 | 1748 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 | ||
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4400 |