4-20mA Digital Electromagnetic Water Flow Meter 220V AC China

4-20mA Digital Electromagnetic Water Flow Meter 220V AC China, Find details about China Digital Water Flow Meter 4-20mA Electromagnetic, Water 220V AC Electromagnetic Flow Meter from 4-20mA Digital Electromagnetic Water Flow Meter 220V AC China

Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Origin
China
HS Code
9028209000
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Origin
China
HS Code
9028209000
Description 4-20mA digital electromagnetic water flow meter 220v ac  china
Intelligent electromagnetic flowmeter consists of two parts, the sensor and converter. It is based on the work of Faraday's law of electromagnetic induction, used to measure the conductivity is greater than 5μS / cm conductive liquid volumetric flow rate, is a measure of the volume flow of conductive medium for induction meter. In addition to measure the volume flow of conductive liquid, it can also be used to measure the volume of a homogeneous liquid-solid two-phase flow of a liquid suspension of acid and alkali and other strong corrosive liquids and slurries, pulp and paper pulp.
Widely used in flow measurement of petroleum, chemical, metallurgy, textile, paper, environmental protection, food and other industrial and municipal administration, water conservancy construction, river dredging and other fields.


Detailed Images  4-20mA digital electromagnetic water flow meter 220v ac  china
4-20mA Digital Electromagnetic Water Flow Meter 220V AC China
4-20mA Digital Electromagnetic Water Flow Meter 220V AC China4-20mA Digital Electromagnetic Water Flow Meter 220V AC China

Specification of  4-20mA digital electromagnetic water flow meter 220v ac  china
Nominal Diameter(mm)
(Special specifications can be customized)
pipeline tetrafluoroethylene lining:DN10~DN2600
Pipeline rubber lining:DN40~DN2600
Flow direction:positive and negative, the net flow
Turndown ratio: 1500:1
Repeatability error:± 0.1% of measured value
 
Accuracy:Pipeline:0.5,1.0
Measured medium temperature: ordinary rubber lining::-20~+60ºC
High-temperature rubber lining: -20~+90ºC
 PTFE lining:-30~+120ºC
High temperature tetrafluoroethylene lining:::-20~+180ºC
Rated working pressure:
(High voltage can be customized)
DN6-DN80:≤2.5MPa
DN100-DN250:≤1.6MPa
DN300-DN2600:≤1.0MPa
Flow rate range:0.1-15m/s
Conductivity range:the measured fluid conductivity≥5μs/cm
Current output:load resistance 0~10mA:0~1.5kΩ
4~20mA:0~750 kΩ
Digital frequency output:transistor output frequency limit can be set with optical isolation within 1 ~ 5000HZ bidirectional open-collector output. External power supply is turned ≤35V maximum collector current of 250mA
 
Power supply:AC220Vor DC24V
Length of straight pipe  requirementsupstream≥5DN,downstream≥2DN
Connection:are used between the meter and piping flange connection, flange dimensions shall comply with the provisions of GB11988
 
Explosion levelsmdIIBT4
Protection class:IP65,special order up to IP68
Ambient temperature:-25~+60ºC
Relative humidity: 5%~95%
Total power consumption:
 
less than 20W



Measure range
Inner diameter(mm)1015202532405065
Qmin(m3/h)0.02830.06360.120.1760.290.4520.71.19
Qmax(m3/h)4.249.5416.9626.543.4267.85106.0179.0
Inner diameter(mm)80100125150200250300350
Qmin(m3/h)1.82.824.416.3611.317.625.434.6
Qmax(m3/h)271.0424.0662.0954.01690265038105190
Inner diameter(mm)400450500550600700800900
Qmin(m3/h)45.257.277.685.5101.0138.0180.0229.0
Qmax(m3/h)67808570106001280015200207002710034300
Inner diameter(mm)10001100120014001600180020002200
Qmin(m3/h)282.0342.0407.0554.1732.7916.01131.01368.4
Qmax(m3/h)42400513006100083121108566137404169635205258

Select the lining material
Should be based on the measured medium temperature corrosive wear and to select the lining material 
Lining material corrosion resistance Working temperatureApplication
 NeGeneral resistance to low concentrations of acid salt corrosion-20~70ºClower industrial water effluent pH and salt concentration
 POHas an excellent wear resistance, abrasion resistance slurry dedicated to strong, not decay-10~60ºCLiquids containing solid particles (slurry pulp, etc.)
 FEP1 corrosion resistant and quite PTFE
 2 high mechanical strength, good wear resistance
3 table smooth, easy adhesion precipitate
 4 have strong abrasive media fluid good resistance to outside negative, anti-vacuum effect
-40~180ºCexcept mortar. Like with PTFE can be used for drinks and other health requirements of the media
PTFElmost all of the corrosion resistant chemical media, poor wear resistance-40~180ºCNot be used for pipes and wear strong negative fluid

Selective Electrode Materials
Should be based on the measured fluid corrosive to select material of the electrodes, check the manual for special fluids should be corrosion test
 
 
MaterialCodecorrosion resistance
316Lstainless steel V1 applies to a neutral solution of industrial, domestic water, raw water wells, urban sewage
2 weak corrosive acids, bases, salts medium such as carbonic acid, acetic acid, etc.
Hastelloy CHC1 applies to anti-oxidizing acids, such as a mixture of nitric acid, mixed acid, chromic acid and sulfuric acid
2 oxidation resistance salt or other corrosive environments, such as the oxidant Fe, Cu
3 Sea water, alkali solution, the oxide solution has excellent corrosion resistance

4 NA: hydrochloric acid
Hastelloy BHB
1 for the non-oxidizing acids, bases, salts such as sulfuric acid, phosphoric acid, hydrofluoric acid has good corrosion
2 NA: nitrate
Titanium Tiseawater resistant, various chlorides suddenly hypochlorite and a variety of corrosion hydroxide
TaTaexcept hydrofluoric acid, almost all corrosive chemical media capability. But expensive
Platinum Ptsalt solution applicable to all of the acid (fuming sulfuric acid and nitric acid)
TungstenWhas excellent wear resistance, dedicated to the mud, pulp and other abrasive media

Features of  4-20mA digital electromagnetic water flow meter 220v ac  china
  1. Fully digital processing, anti-interference ability, reliable measurement, high accuracy flow measurement range up to 1500: 1
  2. Ultra-Low EMI switching power supply for supply voltage variation range, anti-EMI performance.
  3. 16-bit embedded microprocessors, computing speed, high precision, programmable low-frequency square wave excitation frequency and improve the stability of the flow measurement, low power consumption.
  4. using SMD devices and surface mount (SMT) technology, circuit reliability.
  5. No moving parts inside the pipe l, unimpeded flow of parts, measuring almost no additional pressure loss.
  6. range in the field can be modified online according to the actual needs.
  7.  measurements and velocity distribution, the physical parameters of the fluid pressure, temperature, density, viscosity and the like.
  8. High-resolution backlit LCD display, full Chinese menu, easy to use, simple to operate, easy to understand.
  9.  have RS485, RS232, Hart, and Modbus and other digital communication signal output. (Optional)
  10.  has a self-test and self-assertion.
  11.  total hourly recording function to record the total flow in units of hours for hourly metering system (optional)
  12.  have three internal totalizer can show the cumulative amount of forward and reverse cumulative amount of the difference between the volume totalizer, the internal power-down features not always, can record 16 power-down times. (Optional)
  13.  IR handheld operator, 115KHZ communication speed, long-distance non-contact operation of all functions converter (optional)



Order guide 4-20mA digital electromagnetic water flow meter 220v ac  china

Model number Directions
LDG -         
Path         10-2600mm
Combination SSpliT
CCompact
Electrode materialMSS
TTi
DTa
HHastelloy
PPt
NNi
Output mode 0No output
14-20mA/1-5KHz
24-20mA
Lining material XRubber
FTeflon
PPolyethylene
JPolyurethane
Local display0no
1yes
Communication0no
1RS485
2RS232
3Mobdus
4Hart
Ground0No grounding ring
1 grounding ring
2The ground electrode
Limit traffic(n)Limit the flow (range) m3 / h

 Example: use of a local display type electromagnetic flowmeter sewage pipes for user DN50, require rubber lining, stainless steel electrodes, 4 ~ 20mA output, no communication, limit the flow of 30m3 / h. Models should be: LDG-50S-M1X100-30