Jumper tolerance requirement | |
Overall length (L) (M) | length of tolerance(CM) |
0<L≤20 | +10/-0 |
20<L≤40 | +15/-0 |
L>40 | +0.5%L/-0 |
Cable Count | Out sheath Diameter (MM) | Weight (KG) | Minimum allowable Tensile Strength (N) | minimum allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage temperature (ºC) | |||
short term | long term | short term | long term | short term | long term | ||||
1 | (2.0±0.1)×(3.0±0.2) | 8 | 100 | 50 | 500 | 100 | 20D | 10D | -20 ~~ +60 |
Cable Count | Out sheath Diameter (MM) | Weight (KG) | Minimum allowable Tensile Strength (N) | minimum allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage temperature (ºC) | |||
short term | long term | short term | long term | short term | long term | ||||
1 | (2.0±0.2)×(5.0±0.3) | 21.7 | 400 | 200 | 2200 | 1000 | 20D | 10D | -20 ~~ +60 |
Item | Parameter | Reference | |||
Single mode | Multimode | ||||
Standard | Elite | Standard | Elite | ||
Insertion loss | Typical≤0.30dB Max≤0.75dB | Typical≤0.15dB Max≤0.35dB | Typical≤0.50dB Max≤0.25dB | Typical≤0.10dB Max≤0.35dB | IEC 61300-3-34 |
Return loss | ≥ 50dB (PC) ≥ 60dB (APC) | ≥ 55dB (PC) ≥ 65dB (APC) | ≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 |
Test | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable retention | 100N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |