China FTTH Drop Cable Fiber Optic Patch Cord with Sc Connector, Find details about China Fiber Optic Drop Cable Patch Cord, Drop Cable Patch Cord from FTTH Drop Cable Fiber Optic Patch Cord with Sc Connector
Jumper tolerance requirement | |
Overall length (L) (M) | length of tolerance(CM) |
0<L≤20 | +10/-0 |
20<L≤40 | +15/-0 |
L>40 | +0.5%L/-0 |
Cable Count | Out sheath Diameter (MM) | Weight (KG) | Minimum allowable Tensile Strength (N) | minimum allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage temperature (ºC) | |||
short term | long term | short term | long term | short term | long term | ||||
1 | (2.0±0.1)×(3.0±0.2) | 8 | 100 | 50 | 500 | 100 | 20D | 10D | -20 ~~ +60 |
Cable Count | Out sheath Diameter (MM) | Weight (KG) | Minimum allowable Tensile Strength (N) | minimum allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage temperature (ºC) | |||
short term | long term | short term | long term | short term | long term | ||||
1 | (2.0±0.2)×(5.0±0.3) | 21.7 | 400 | 200 | 2200 | 1000 | 20D | 10D | -20 ~~ +60 |
Item | Parameter | Reference | |||
Single mode | Multimode | ||||
Standard | Elite | Standard | Elite | ||
Insertion loss | Typical≤0.30dB Max≤0.75dB | Typical≤0.15dB Max≤0.35dB | Typical≤0.50dB Max≤0.25dB | Typical≤0.10dB Max≤0.35dB | IEC 61300-3-34 |
Return loss | ≥ 50dB (PC) ≥ 60dB (APC) | ≥ 55dB (PC) ≥ 65dB (APC) | ≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 |
Test | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable retention | 100N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |