Glass Lined Agitated Filter

China Glass Lined Agitated Filter, Find details about China Glass Lined Filter, Glass Lined Agitated Filter from Glass Lined Agitated Filter

Model NO.
GLF-K50 to F30000
Distillation Equipment Type
Filter
Extraction Tower Type
Glass Lined Agiteted Filter
Pressure
Low Pressure
Condition
New
Trademark
DEWOJIN
Specification
K50-K30000
Origin
Zibo, China
HS Code
8419
Model NO.
GLF-K50 to F30000
Distillation Equipment Type
Filter
Extraction Tower Type
Glass Lined Agiteted Filter
Pressure
Low Pressure
Condition
New
Trademark
DEWOJIN
Specification
K50-K30000
Origin
Zibo, China
HS Code
8419
Except for Glass lined reactor,we also make non-standard glass lined equipment such as Glass Lined Filter, Nutsche Filter etc.
Glass Lined Filter:
Glass Lined Agitated Filter



Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants is an ideal material for anti acid & alkali corrosion and its surface is very easy to wash and no contamination to mediums. It's widely used in Petrochemicals, light industry, pharmaceuticals, pesticide, foodstuff, dyes, scientific research etc.
2. Capacity:
 Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants capacity: 10 to 30000Liter
3. Structure: Open type (k-type) or closed type( F-type)
4. Material: Vessel: glass lined; Jacket: MS.
5. Design pressure: Vessel: 0.2Mpa or 0.3Mpa or 0.4-0.6Mpa or 1.0Mpa
Jacket pressure: 0.6Mpa

6. Design Temperature: 200 degree C.
7. Accessories: One complete set of Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants generally with motor with Reducer, Seal (optional: Stuffing box, Single mechanical seal, Double mechanical seal ), Agitator, Thermometer pocket, bottom discharge Valve.
8. Properties and Advantages:
1) Have the advantages of glass' anti-corrosion and stability and metal's strength. 
Corrosion resistance: Organic or inorganic acid, organic solvent and weak alkaline corrosion    (not  including hydrofluoric acid, containing fluorine medium, phosphoricacid, and alkali concentration greater -than 30% and temperature greater-than or equal 180 Degree Cent. )
2) No contamination: Beacause
Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants inside surface is glass lined so its no contamination to medium.
3) Very eash to wash:
Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants inside surface is glass lined, very easy to wash.
4) Pressure resistance:
a) with Packing box: Vessel: Less-than or equal 0.20MPa; Jacket: Less-than or equal 0.6MPa
b) with Single Mechanical seal: Vessel: Equal or less-than 0.30Mpa;Jacket: Less-than or equal 0.6MPa
c) with Double mechanical seal: Vessel: Equal or less than 0.6Mpa; Jacket: Less-than or equal 0.6MPa
5) Operation temperature: 0 to 200 Degrees Cent.
6) Glass layer thickness: 0.8 - 2.0mm
7) Cool shock: 110 Degrees Cent.
8) Thermo-shock: 120 Degrees Cent.


9. Note:
1. Temperature should be slowly changed while heating or cooling Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants avoid damaging glass layer.
2.
Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants can not be used in hydrofluoric acid, medium containing fluorine, phosphoric acid, and alkali concentration greater -than 30% and temperature greater-than or equal 180 Degree Cent. )

10. Specification and Dimension of Glass Lined Reactor With Heating/Cooling Jacket For Chemical Plants  
Norminal Capacity LActual Capacity LJacket Heating Area   m2ReducerSpecification of Packing Box 
     DN
Specification of Drain Valve
    DN
AgitatorRotation Speed r/min                               Size(mm) 
Achor
Frame
Impeller
Turbin
Paddle
DD0D1D2D3D4HH1H2H3L hWeight
Kg
Achor
Frame
Impeller
Turbin
Paddle
K50700.59BLD0.75-1406563/8585/130500350600708270/48030028092320605090365
K1001270.9BLD0.75-1406563/8585/130600420700826270/580350315923225060110435
K2002411.5BLD1.1-1508063/8585/130700490800927300/765350340938247060130580
K3003611.94BLD3-2658063/8585/1308005609001055350/8653803751098276080150780
K5005792.71BLD3-2658063/8585/13090063010001156350/10654004001098302080150945
K100012384.54BLD4-38010063/8585/1301200840130014884009501275500480124234301002101685
K150017145.38BLD4-38010063/8585/13013009101450163940010801470600505124236601002101990
K200021527.2BLD4-38010063/8585/13013009101450163940010801810600505124240101002102225
K300032008.9BLD5.5-39512563/8585/130160011201750198145013001810600590130241591302403190
K5000528613.0BLD7.5-49512563/8585/130175012001900213145014002428700628138248401302704455
K6300624815.2BLD7.5-49512563/8585/130175012001900213145014002828700628138252401302704950
K8000803817.05BLD11-511012563/8585/130200014002200250245516502800780700145550001503006210
K100001020022.6BLD11-511015063/8585/130220015402400270851018002955800750149552851503307680
F300036258.9BLD5.5-395125/85/130160011201750198160013002255106015013024190/2402910
F5000585813.2BLD7.5-395125/85/130175012001900213160014002911120015013024900/2704100
F6300682015.4BLD7.5-495125/85/130175012001900213160014003311120015013825330/2704595
F8000927318.0BLD11-595125/85/130200014002200250280016503465135018014555510/3306235
F100001144320.5BLD11-5110150/85/130220015402400270880018003570145018014955690/3607845
F125001364024.5BLD11-5110150/85/130220015402400270880018004145145018014956450/3608920
F160001744629.5BLD18.5-6130150/85/130240016802600291280019504440145018021807220/36011350
F200002175034.4BLD18.5-6130150/85/130260018202800318290021004700145023021807710/40013545
F300003252042.7BLD22-7140150/85/1303000210032003788110024005240160028022007620/45019860
Glass Lined Agitated Filter