Rco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

China Rco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner, Find details about China Air Conditioner Parts, Capacitor from Rco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

Model NO.
RCO
Shape
Cylinder
Color
Black, Customizable
Terminal
Double Faston, Single Faston, Wires, Cable
Certifications
CQC, CE & RoHS, TUV & VDE, UL
Loading Port
Ningbo, Shanghai, Yiwu, Guangzhou
Package
50-100 Pieces Per Carton, Based on Capacitors Size
Packing Detail
Individual Box Is Available
Supply Ability
1, 200, 000 Piece/Pieces Per Month
Sampls
for Free (The Freight Shoule Be Paid by Custom)
H.S. Code
8532 2590
Delivery Time
15 - 30 Days (Based on Order Quantity)
Payment Term
T/T, L/C at Sight, Cash, Western Union
Shipment Term
Fob, CNF, CIF
MOQ
200 Pieces Per Type
Trademark
TOPO / oooneoo
Transport Package
Export Standard
Specification
IEC60252
Origin
China
HS Code
85322590
Model NO.
RCO
Shape
Cylinder
Color
Black, Customizable
Terminal
Double Faston, Single Faston, Wires, Cable
Certifications
CQC, CE & RoHS, TUV & VDE, UL
Loading Port
Ningbo, Shanghai, Yiwu, Guangzhou
Package
50-100 Pieces Per Carton, Based on Capacitors Size
Packing Detail
Individual Box Is Available
Supply Ability
1, 200, 000 Piece/Pieces Per Month
Sampls
for Free (The Freight Shoule Be Paid by Custom)
H.S. Code
8532 2590
Delivery Time
15 - 30 Days (Based on Order Quantity)
Payment Term
T/T, L/C at Sight, Cash, Western Union
Shipment Term
Fob, CNF, CIF
MOQ
200 Pieces Per Type
Trademark
TOPO / oooneoo
Transport Package
Export Standard
Specification
IEC60252
Origin
China
HS Code
85322590

CD60 (US) Series

Construction

  • Dielectric: aluminium foil & electrolyte paper
  • Bakelite plastic can

Features

  • High class insulating
  • High strength
  • Uneasy broken
  • Reliable and long in service life

Typical applications

  • Suitable for use in single phase A.C. motors

Terminals

  • Double Fast on
  • Cable
 
 
Technical data and specifications
Reference standardsAmerican ANSI /EIA -463
Operating temperature range40-65 ºC
Rated capacitance CR21 µF~1536 µF
Tolerance0~+20%
Rated voltage VR110VAC~330VAC
Rated frequency FR50/60Hz
Dissipation factor tan δtgδ< 0.10   tgδ< 0.15   (20ºC,100Hz)
Surge Volt between lugsApplying 1.25 times rated voltage for 2 seconds
Surge Volt between lug & case2000VAC  10 seconds  non-broken down
Load LifeAccording to the difference working voltage and capacitance, alternation 0.5 - 4 minute turn on
1 time for second,  12500 ~ 50000 times.
 
Dimensions (mm)
Capacitance (uF/MFD)110VAC125VAC165VAC
ΦHΦHΦH
21-2536.569.8536.569.8536.569.85
25-3036.569.8536.569.8536.569.85
30-3636.569.8536.569.8536.569.85
36-4336.569.8536.569.8536.569.85
43-5236.569.8536.569.8536.569.85
47-5636.569.8536.569.8536.569.85
53-6436.569.8536.569.8536.569.85
64-7736.569.8536.569.8536.569.85
72-8636.569.8536.569.8536.569.85
88-10636.569.8536.569.8536.585.72
108-13036.569.8536.569.8536.585.72
124-14936.569.8536.569.8536.585.72
130-15636.569.8536.569.8546.0285.72
145-17436.569.8536.569.8546.0285.72
161-19336.569.8536.569.8546.0285.72
189-22736.569.8536.585.7246.0285.72
216-22736.585.7236.585.7246.02111.12
233-28036.585.7236.585.7246.02111.12
243-29236.585.7236.5111.1246.02111.12
270-32436.585.7236.5111.1246.02111.12
324-38936.5111.1246.0285.7252.37111.12
340-40846.0285.7246.0285.7252.37111.12
378-45446.0285.7246.0285.7252.37111.12
400-48046.0285.7246.0285.7252.37111.12
430-51646.0285.7246.0285.7265.5111.12
460-55246.0285.7246.0285.7265.5111.12
540-64846.02111.1246.02111.1265.5111.12
590-70846.02111.1246.02111.1265.5111.12
645-77452.37111.1252.37111.1265.5111.12
708-85052.37111.1252.37111.1265.5111.12
720-86452.37111.1252.37111.1265.5111.12
800-96052.37111.1252.37111.1265.5111.12
815-97852.37111.1265.5111.1265.5111.12
829-99565.5111.1265.5111.1265.5111.12
850-102065.5111.1265.5111.1265.5111.12
1000-120065.5111.1265.5111.12  
1020-122465.5111.1265.5111.12  
1175-141065.5111.1265.5111.12  
1280-153665.5111.12    
Dimensions (mm)
Capacitance (uF/MFD)220VAC250VAC330VAC
ΦHΦHΦH
21-2536.569.8536.569.8536.585.72
25-3036.569.8536.569.8536.585.72
30-3636.569.8536.585.7246.0285.72
36-4336.569.8536.585.7246.0285.72
43-5236.585.7236.585.7246.0285.72
47-5636.585.7236.585.7246.0285.72
53-6436.585.7246.0285.7246.02111.12
64-7746.0285.7246.0285.7246.02111.12
72-8646.0285.7246.0285.7246.02111.12
88-10646.0285.7246.02111.1252.37111.12
108-13046.0285.7246.02111.1265.5111.12
124-14946.02111.1246.02111.1265.5111.12
130-15646.02111.1246.02111.1265.5111.12
145-17452.37111.1252.37111.1265.5111.12
161-19352.37111.1252.37111.1265.5111.12
189-22752.37111.1265.5111.1265.5111.12
216-22765.5111.1265.5111.1265.5111.12
233-28065.5111.1265.5111.1265.5111.12
243-29265.5111.1265.5111.1265.5111.12
270-32465.5111.1265.5111.1265.5111.12
324-38965.5111.1265.5111.12  
340-40865.5111.1265.5111.12  
378-45465.5111.1265.5111.12  
400-48065.5111.1265.5111.12  
430-51665.5111.1265.5111.12  
460-552      
540-648      
590-708      
645-774      
708-850      
720-864      
800-960      
815-978      
829-995      
850-1020      
1000-1200      
1020-1224      
1175-1410      
1280-1536      
Note: Can be manufactured according to customer's request.

Rco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

Capacitors Details:
Rco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air ConditionerRco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

High-Return Solutions

Specifically to your satisfaction.

Most of our customers have been doing business with us for more than a decade, with full trust in our capabilities and reliability. We take pride in solving different challenges to customers in a productive way. Maybe you need a special collection, a distinct packing, an urgent delivery or any other supports, our team is here ready to offer you the integrated solutions and save you more.
Rco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

 

OEM and ODM

Contract manufacturing and housing molding for your brand.

Your brand and personal preferences could be custom on the products and packings. As a comprehensive capacitor manufactuer, Topo possesses the extensive custom design capabilities to meet your specific requirements, which help you to extend your brand's advantages.
Rco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

 

ECO Friendly and Full Material

Speaking of quality, green material is the very start. Topo only utilizes the materials friendly to the environment with a social responsibility perspective. Besides, great quality films make excellent capacitors. We never cut corners on materials, but apply full materials for each parts.
Rco810 Rco410 Hard Start Relay Capacitor Used on Air Conditioner

 

Free Sample for Testing

An adequate amount of free samples could be offered for your testing of the important electrical parameters. From these aspects those prove that our products are of high quality and can stand the tests.

Rest assured and get your samples right away!


 

FAQs

Topo knows about your general concerns. Check the Q&A that will help you save time and worries in the first place. If your question is not listed, please contact us and we are happy to help.

Can the Topo capacitors be used in the AC and DC circuits?
Generally, our capacitors could apply with both circuits of AC and DC. Yet most of our products are for AC circuit purpose.
Are the Topo capacitors compliance products of EU CE and RoHS?
Yes. All of our capacitors comply with the CE, VDE, and RoHS standards.
Can I print my brand on the capacitor?
Absolutely. Topo has the capability of OEM and ODM. You are free to choose custom services or our regular high-standard capacitors.
How long does a quotation take?
In most cases, your enquiry will be answered within 24 hours. Rest assured that your enquiry will be taken seriously.
Can I get samples?
Sure. We offer adequate samples for your testing free of charge. However, the freight is not covered.