X-ray Fluorescence Sulfur in Fuel Oil Analyzer for Measuring The Low Range of Sulfur in Bunker and Marine Fuel

China X-ray Fluorescence Sulfur in Fuel Oil Analyzer for Measuring The Low Range of Sulfur in Bunker and Marine Fuel, Find details about China ASTM D4294 Sulfur Analyzer, Sulfur in Oil Analyzer from X-ray Fluorescence Sulfur in Fuel Oil Analyzer for Measuring The Low Range of Sulfur in Bunker and Marine Fuel

Model NO.
GD-4294
Power Source
AC220V
Sulfur in Fuel Analysis
X-ray Fluorescence Oil Sulfur Analyzer
Sulfur in Petroleum
Sulfur in Fuel Analysis to ASTM D4294, ISO8754
Sulfur in Jet Fuel
ASTM D4294 Sulfur Content Tester
Measurement Range
10ppm to 5%
Detection Limit
10 Ppm
Oil Sample Quantity
3 Ml
Measurement Time
It Can Be Set to 30s or 60s or 90s or 120s or 150s
Calibration Curve Numbers
It Can Save 10 Calibration Curves
Touch Screen
8-Inch (1024*768)Capacitive Touch Screen
Communication Port
RS232 Serial Port
Trademark
GOLD
Transport Package
Wooden Case or as Required
Specification
Refer to ASTM D4294 and ISO 8754
Origin
Chongqing of China
HS Code
9031809090
Model NO.
GD-4294
Power Source
AC220V
Sulfur in Fuel Analysis
X-ray Fluorescence Oil Sulfur Analyzer
Sulfur in Petroleum
Sulfur in Fuel Analysis to ASTM D4294, ISO8754
Sulfur in Jet Fuel
ASTM D4294 Sulfur Content Tester
Measurement Range
10ppm to 5%
Detection Limit
10 Ppm
Oil Sample Quantity
3 Ml
Measurement Time
It Can Be Set to 30s or 60s or 90s or 120s or 150s
Calibration Curve Numbers
It Can Save 10 Calibration Curves
Touch Screen
8-Inch (1024*768)Capacitive Touch Screen
Communication Port
RS232 Serial Port
Trademark
GOLD
Transport Package
Wooden Case or as Required
Specification
Refer to ASTM D4294 and ISO 8754
Origin
Chongqing of China
HS Code
9031809090
GD-4294 X-ray Fluorescence Sulfur in Fuel Oil Analyzer for measuring the low range of sulfur in bunker and marine fuel


Test Significance of Sulfur Analysis

The XRF Sulfur in Fuel Oil Analyzer is an important device to meet the requirements for monitoring sulfur at these various levels, with the ability to measure sulfur over a broad range of concentrations and into the future as sulfur levels become even lower.

The X-ray Fluorescence Sulfur in Fuel Oil Analyzer can be used for sulfur in fuel analysis to ASTM D4294, ISO8754 and IP336.


Features of Sulfur in Fuel Oil Analyzer(ASTM D4294)

(1) With electrical, mechanical and microprocessor integration design, so it is compact and beautiful;

(2) It can determine various products and in a wide measurement range. It is rapid for analysis and it only need little standard sample.

(3) Adopts fluorescence intensity ratio analysis methods, it can make correction to temperature and pressure automatically and it can also make correction to ratio of carbon and hydrogen (C/H).

(4) 8-inch (1024*768)capacitive touch screen. 

(5) It  can determine its working state and electric parameters by making repeatability test and spectrum scan using reference samples.

(6) Equipped with a RS232 serial port, it can connect with any computer .

(7) It takes disposable sample cell with Mylar film, so it can avoid cross contamination. Sample cell is made by a multifunction pressure shaping device, so it is rapid and convenient. There is a hole on the sample cell cover and you can record sample serial number, S% (m/m), and date on the sample cell cover.

(8) The sample holder is installed on a slide rail,It is convenient and it can avoid any contamination to detection system.

(9) It can save large quantity of test data. You can browse test data and calibration curves at any time.

(10) The sulfur analyzer uses a thermal printer, so it is easy to replace printing paper.

(11) Tightly protection measures to avoid oil leakage. The sample cell is placed on the leakage protection device. The sample cell can enter into the detection system together with the leakage protection device only during sample analysis procedures. If the instrument is not at sample analysis state, the leakage protection device will move out, so this can avoid any contamination to the detection system.

(12) Its safe X-ray protection measures can keep people from injury of X-ray radiation. 


Main Parameters:
 
1Measurement range20 ppm to 5%
2Repeatability (r)<0.02894(S+0.1691)
3Reproducibility (R)<0.1215(S+0.05555)
4Detection limit10 ppm
5Oil sample quantity3 ml (it is equal to sample depth of 3 mm~4 mm)
6Measurement timeit can be set to 30s or 60s or 90s or 120s or 150s
7It can make determination automatically for single sample. Replication times can set 1,2, 3, 5, 10 at random; it will show average value and standard deviation at end of measurement.
8Calibration curve numbersit can save 10 calibration curves
9Working condition

a. Ambient temperature: 5~30ºC

b. Relative humidity: ≤85% (30 ºC)

10Power supplyAC 220V±20V, 50 Hz/60Hz; Rated power: 50 W
11Size and weight460mm*260mm*260mm, 12 kg