China Drum Chain Grate Stoker Coal Boiler Manufacturer, Find details about China Boiler, Steam Boiler from Drum Chain Grate Stoker Coal Boiler Manufacturer
Technical parameters of new SZL series steam boiler | ||||||
SZL6-1.6-AII | SZL8-1.6-AII | SZL10-1.6-AII | SZL15-1.6-AII | SZL20-1.6-AII | SZL25-1.6-AII | |
(t/h) Rated evaporation capacity | 6 | 8 | 10 | 15 | 20 | 25 |
(Mpa) Rated working pressure | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 |
(ºC) Rated steam temperature | 204 | 204 | 204 | 204 | 204 | 204 |
(ºC) Feed water temperature | 105 | 105 | 105 | 105 | 105 | 105 |
() Radiation heating area | 18.7 | 25.8 | 26.3 | 44 | 71.6 | 86.7 |
() Convection heat area | 121 | 150 | 162 | 280 | 338 | 380 |
()Economizer heat area | 90.24 | 112.8 | 150.4 | 188 | 195 | 220 |
() Grate effective area | 7.78 | 10.1 | 11.8 | 17.8 | 22.5 | 25.12 |
Suitable coal type | ||||||
(kg/h) Coal consumption | 950 | 1250 | 1540 | 2180 | 3038 | 3600 |
(%) design thermal efficiency | 80.8 | 80 | 80.7 | 80.6 | 82.4 | 80.6 |
(t) Max transport weight | 23/18 | 28/21 | 32/24 | 43/26 | 46/31 | 49/44 |