Double Suction Split Casing Centrifugal Water Pump with Electrical Motor

China Double Suction Split Casing Centrifugal Water Pump with Electrical Motor, Find details about China Centrifugal Pump, Water Pump from Double Suction Split Casing Centrifugal Water Pump with Electrical Motor

Model NO.
ANS
Power
Electric
Start Up
Electric Pump
Type
Jet Pump
Application
Clarified Water Pump, Chemical Pump
Industry
Industry
Media
Water
Performance
High Efficency Energy-Save
Theory
Centrifugal Pump
Solid Gerains
up to 80mg/L
Paint
Blue
OEM
Ok
Trademark
TONGKE
Transport Package
Wooden-Case
Specification
DN80-1400
Origin
China
HS Code
8413709990
Model NO.
ANS
Power
Electric
Start Up
Electric Pump
Type
Jet Pump
Application
Clarified Water Pump, Chemical Pump
Industry
Industry
Media
Water
Performance
High Efficency Energy-Save
Theory
Centrifugal Pump
Solid Gerains
up to 80mg/L
Paint
Blue
OEM
Ok
Trademark
TONGKE
Transport Package
Wooden-Case
Specification
DN80-1400
Origin
China
HS Code
8413709990
Tongke ASN series Double Suction Split casing Centrifugal water Pump with motor
Double Suction Split Casing Centrifugal Water Pump with Electrical Motor

Product Description

Double Suction Split Casing Centrifugal Water Pump with Electrical Motor
Model ASN and ASNV pumps are single stage double suction split volute casing(case) centrifugal pump is the new generation of high performance single stage double suction centrifugal pump, mainly used for water plant, air conditioning, water recycling, heating systems, and high-rise building water supply, irrigation and drainage pumping stations, power plants, industrial water supply system, Fire systems, shipbuilding industry, and other places of fluid transmission.
 
Model Meaning
ANS(V) 150-350(I)A
ANS :  Split casing horizontal centrifugal pump
(V) :   Vertical type
150:   Outlet diameter of pump 150mm
350:   Nominal diameter of impeller 350mm
A:     Impeller via first cutting
(I):     As flow-expanded type

 

 

Product Parameters

Operation Parameter

DiameterDN 80-800MM
CapacityNo more than 11600m³/h
HeadNo more than 200m
Liquid TemperatureUp to 105ºC

 Recommended Material Configuration

Recommended Material Configuration (For reference only)
ItemClean waterDrink waterSewage waterHot waterSea water
Case & CoverCast iron HT250SS304Ductile iron QT500Carbon steelDuplex SS 2205/Bronze/SS316L
ImpellerCast iron HT250SS304Ductile iron QT5002Cr13Duplex SS 2205/Bronze/SS316L
Wearing ringCast iron HT250SS304Ductile iron QT5002Cr13Duplex SS 2205/Bronze/SS316L
ShaftSS420SS42040Cr40CrDuplex SS 2205
Shaft sleeveCarbon steel/SSSS304SS304SS304Duplex SS 2205/Bronze/SS316L
Remarks:  Detailed material list will according to liquid and site conditions

Product Advantage

ASN pump Advantage have to say!!
1.Compact structure nice appearance,good stability and easy installation
2.Stable running the optimally designed double-suction impeller makes the axial force reduced to the minimum and has a blade-style of very excellent hydraulic performance,both internal surface of the pump casing and the impeller s surace, being precisely cast, are extremely smooth and have a notable performance vapourcorrosion resisting and a high efficiency
3. The pump case is double volute structured, which greatly reduces radial force, lightens bearing's load and long bearing's service life
4.Bearing use SKF and NSK bearings to guarantee a stable running, low noise and long duration. 
5.Shaft seal use BURGMANN mechanical or stuffing seal to ensure a 8000h non-leak running. 
6 . Flange standard: GB, HG, DIN, ANSI standard, according to your requirements.

Detailed Photos

Double Suction Split Casing Centrifugal Water Pump with Electrical Motor

Application


Double Suction Split Casing Centrifugal Water Pump with Electrical Motor Municipal, construction, ports
Chemical industry, paper making, paper pulp industry
∧ Mining and metallurgy;
∧ Fire control
∧ Environmental protection

Double Suction Split Casing Centrifugal Water Pump with Electrical Motor



√ NOTE before order
Parameters necessary to be submitted at order Double Suction Split casing Centrifugal water Pump with motor

1. Pump model and the flow, head (including the system loss), NPSHr at the point of the desired working condition.

2. Type of shaft seal (must be noted either mechanical or packing seal and, if not, delivery of the mechanical seal structure will be made).

3. Moving direction of the pump (must be noted in case of a CCW installation and, if not, delivery of a clockwise installation will be made).

4. Parameters of the motor (Y series motor of IP44 is generally used as the low-voltage motor with a power <200KW and, when to use a high voltage one, please note its voltage, protective rating, insulation class, way of cooling, power, number of polarity and manufacturer).

5. The materials of pump casing, impeller, shaft etc. parts. (delivery with the standard allocation will be made if without being noted).

6. Medium temperature (delivery upon a constant-temperature medium will be made if without being noted).

7. When the medium to be transported is corrosive or contains solid grains, please note the features of it.

 

Company Profile

Double Suction Split Casing Centrifugal Water Pump with Electrical MotorDouble Suction Split Casing Centrifugal Water Pump with Electrical MotorDouble Suction Split Casing Centrifugal Water Pump with Electrical MotorDouble Suction Split Casing Centrifugal Water Pump with Electrical MotorDouble Suction Split Casing Centrifugal Water Pump with Electrical MotorDouble Suction Split Casing Centrifugal Water Pump with Electrical Motor