Cvv Copper Control Cable Cvv -S Cvv -Swa

China Cvv Copper Control Cable Cvv-S Cvv-Swa, Find details about China Cvv Copper Control Cable, Cvv-Swa Cable from Cvv Copper Control Cable Cvv-S Cvv-Swa

Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CCC
Brand
Hongda
Trademark
OEM
Transport Package
in Drum or in Coil
Specification
1.5 2.5 4 6 10 16 25 35 50 70 95
Origin
Henan
HS Code
8544492100
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CCC
Brand
Hongda
Trademark
OEM
Transport Package
in Drum or in Coil
Specification
1.5 2.5 4 6 10 16 25 35 50 70 95
Origin
Henan
HS Code
8544492100

Application:   Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and anti-abrasion quality.

Construction- Conductors:Annealed Copper Wire
- Insulation : PVC
- Core Identification : Coloring Method - below 4 cores
   (2 cores - Black, White /3 cores - Black, White, Red )
   Numbering Method (Above 5 cores)
- Sheath : PVC

 

       
Mobile: +86 15037165923      
 

Class and SymbolsPVC Insulated PVC Sheathed Control Cable:CVV
PVC Insulated PVC Sheathed Control Cable (Solid Type):CVS
PVC Insulated PVC Sheathed Control Cable (Shield Type):CVV-S, CVV-SB
Flame-Retardant PVC Insulated PVC Sheathed Control Cable:FR-CVV
Flame-Retardant PVC Insulated PVC Sheathed Control Cable (Shield Type):TFR-CVVS

 

2 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
20.57/0.300.81.810.036.00.016298500/D
0.757/0.370.81.810.024.50.0142110500/D
17/0.400.81.810.518.10.0135115500/D
1.57/0.500.81.811.012.10.0115135500/D
2.57/0.670.81.812.07.410.0093180500/D
47/0.851.01.814.54.610.0092255500/D
67/1.041.01.815.53.080.0078320500/D

3 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
30.57/0.300.81.810.036.00.0162110500/D
0.757/0.370.81.810.524.50.0142125500/D
17/0.400.81.811.018.10.0135135500/D
1.57/0.500.81.811.512.10.0115160500/D
2.57/0.670.81.813.07.410.0093220500/D
47/0.851.01.815.04.610.0092315500/D
67/1.041.01.816.53.080.0078405500/D

4 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
40.57/0.300.81.811.036.00.0162130500/D
0.757/0.370.81.811.524.50.0142150500/D
17/0.400.81.811.518.10.0135160500/D
1.57/0.500.81.812.512.10.0115195500/D
2.57/0.670.81.814.07.410.0093265500/D
47/0.851.01.816.54.610.0092390500/D
67/1.041.01.817.03.080.0078510500/D

       
Mobile: +86 15037165923      

5 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
50.57/0.300.81.811.536.00.0162150500/D
0.757/0.370.81.812.524.50.0142175500/D
17/0.400.81.812.518.10.0135190500/D
1.57/0.500.81.813.512.10.0115230500/D
2.57/0.670.81.815.07.410.0093320500/D
47/0.851.01.818.04.610.0092470500/D
67/1.041.01.819.53.080.0078620500/D

6 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
60.57/0.300.81.812.536.00.0162165500/D
0.757/0.370.81.813.024.50.0142190500/D
17/0.400.81.813.518.10.0135205500/D
1.57/0.500.81.814.512.10.0115255500/D
2.57/0.670.81.816.07.410.0093355500/D
47/0.851.01.819.54.610.0092525500/D
67/1.041.01.821.03.080.0078690500/D

7 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
70.57/0.300.81.812.536.00.0162170500/D
0.757/0.370.81.813.024.50.0142200500/D
17/0.400.81.813.518.10.0135215500/D
1.57/0.500.81.814.512.10.0115270500/D
2.57/0.670.81.816.07.410.0093380500/D
47/0.851.01.819.54.610.0092570500/D
67/1.041.01.821.03.080.0078795500/D

8 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
80.57/0.300.81.813.536.00.0162195500/D
0.757/0.370.81.814.024.50.0142230500/D
17/0.400.81.814.518.10.0135250500/D
1.57/0.500.81.815.512.10.0115310500/D
2.57/0.670.81.817.57.410.0093440500/D
47/0.851.01.821.04.610.0092660500/D
67/1.041.01.823.03.080.0078875500/D

       
Mobile: +86 15037165923      
9 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
90.57/0.300.81.814.036.00.0162220500/D
0.757/0.370.81.815.024.50.0142265500/D
17/0.400.81.815.518.10.0135285500/D
1.57/0.500.81.816.512.10.0115355500/D
2.57/0.670.81.818.57.410.0093505500/D
47/0.851.01.822.54.610.0092760500/D
67/1.041.01.824.53.080.00781015500/D

10 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
100.57/0.300.81.815.536.00.0162240500/D
0.757/0.370.81.816.024.50.0142285500/D
17/0.400.81.816.518.10.0135310500/D
1.57/0.500.81.818.012.10.0115385500/D
2.57/0.670.81.820.07.410.0093550500/D
47/0.851.01.824.54.610.0092825500/D
67/1.041.01.827.03.080.00781100500/D

11 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
110.57/0.300.81.815.536.00.0162255500/D
0.757/0.370.81.816.524.50.0142315500/D
17/0.400.81.817.018.10.0135340500/D
1.57/0.500.81.818.512.10.0115425500/D
2.57/0.670.81.821.07.410.0093605500/D
47/0.851.01.825.04.610.0092915500/D
67/1.041.01.827.53.080.00781220500/D

12 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
120.57/0.300.81.815.536.00.0162265500/D
0.757/0.370.81.816.524.50.0142320500/D
17/0.400.81.817.018.10.0135345500/D
1.57/0.500.81.818.512.10.0115440500/D
2.57/0.670.81.821.07.410.0093630500/D
47/0.851.01.825.04.610.0092950500/D
67/1.041.01.827.53.080.00781270500/D


13 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
130.57/0.300.81.816.536.00.0162295500/D
0.757/0.370.81.817.524.50.0142355500/D
17/0.400.81.818.018.10.0135380500/D
1.57/0.500.81.819.512.10.0115485500/D
2.57/0.670.81.822.07.410.0093695500/D
47/0.851.01.826.54.610.00921050500/D
67/1.041.01.829.03.080.00781405500/D


14 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.)
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
140.57/0.300.81.816.536.00.0162300500/D
0.757/0.370.81.817.524.50.0142360500/D
17/0.400.81.818.018.10.0135390500/D
1.57/0.500.81.819.512.10.0115495500/D
2.57/0.670.81.822.07.410.0093715500/D
47/0.851.01.826.54.610.00921085500/D
67/1.041.01.829.03.080.00781455500/D


15 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
150.57/0.300.81.817.036.00.0162330500/D
0.757/0.370.81.818.524.50.0142395500/D
17/0.400.81.819.018.10.0135425500/D
1.57/0.500.81.820.512.10.0115545500/D
2.57/0.670.81.823.07.410.0093785500/D
47/0.851.01.828.04.610.00921195500/D
67/1.041.01.831.03.080.00781600500/D


16 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
160.57/0.300.81.817.036.00.0162330500/D
0.757/0.370.81.818.524.50.0142400500/D
17/0.400.81.819.018.10.0135435500/D
1.57/0.500.81.820.512.10.0115555500/D
2.57/0.670.81.823.07.410.0093805500/D
47/0.851.01.828.04.610.00921230500/D
67/1.041.01.831.03.080.00781650500/D


17 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
170.57/0.300.81.818.036.00.0162355500/D
0.757/0.370.81.819.024.50.0142430500/D
17/0.400.81.819.518.10.0135465500/D
1.57/0.500.81.821.512.10.0115595500/D
2.57/0.670.81.824.07.410.0093865500/D
47/0.851.01.829.54.610.00921315500/D
67/1.041.01.932.53.080.00781785500/D


18 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
180.57/0.300.81.818.036.00.0162360500/D
0.757/0.370.81.819.024.50.0142435500/D
17/0.400.81.819.518.10.0135475500/D
1.57/0.500.81.821.512.10.0115605500/D
2.57/0.670.81.824.07.410.0093885500/D
47/0.851.01.829.54.610.00921350500/D
67/1.041.01.932.53.080.00781835500/D

19 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
190.57/0.300.81.818.036.00.0162365500/D
0.757/0.370.81.819.024.50.0142445500/D
17/0.400.81.819.518.10.0135480500/D
1.57/0.500.81.821.512.10.0115620500/D
2.57/0.670.81.824.07.410.0093905500/D
47/0.851.01.829.54.610.00921385500/D
67/1.041.01.932.53.080.00781885500/D

20 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
200.57/0.300.81.819.036.00.0162390500/D
0.757/0.370.81.820.024.50.0142475500/D
17/0.400.81.820.518.10.0135515500/D
1.57/0.500.81.822.512.10.0115665500/D
2.57/0.670.81.825.57.410.0093975500/D
47/0.851.01.831.04.610.00921490500/D
67/1.041.02.034.53.080.00782040500/D

21 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
210.57/0.300.81.819.036.00.0162400500/D
0.757/0.370.81.820.024.50.0142490500/D
17/0.400.81.820.518.10.0135530500/D
1.57/0.500.81.822.512.10.0115685500/D
2.57/0.670.81.825.57.410.00931005500/D
47/0.851.01.831.04.610.00921540500/D
67/1.041.02.034.53.080.00782040500/D

22 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
220.57/0.300.81.820.036.00.0162430500/D
0.757/0.370.81.821.024.50.0142520500/D
17/0.400.81.821.518.10.0135565500/D
1.57/0.500.81.823.512.10.0115730500/D
2.57/0.670.81.82657.410.00931070500/D
47/0.851.01.932.54.610.00921655500/D
67/1.041.02.036.53.080.00782245500/D

23 Core CVV Control Cable

       
Mobile: +86 15037165923      
 

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
230.57/0.300.81.819.536.00.0162440500/D
0.757/0.370.81.821.024.50.0142540500/D
17/0.400.81.821.518.10.0135585500/D
1.57/0.500.81.823.512.10.0115755500/D
2.57/0.670.81.826.57.410.00931105500/D
47/0.851.01.932.54.610.00921710500/D
67/1.041.02.036.53.080.00782330500/D

24 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
240.57/0.300.81.821.036.00.0162460500/D
0.757/0.370.81.822.024.50.0142560500/D
17/0.400.81.823.018.10.0135605500/D
1.57/0.500.81.824.512.10.0115785500/D
2.57/0.670.81.828.07.410.00931150500/D
47/0.851.02.034.54.610.00921795500/D
67/1.041.02.036.53.080.00782330500/D

25 Core CVV Control Cable

       
Mobile: +86 15037165923      
 

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
250.57/0.300.81.821.036.00.0162490500/D
0.757/0.370.81.822.524.50.0142595500/D
17/0.400.81.823.018.10.0135645500/D
1.57/0.500.81.825.512.10.0115835500/D
2.57/0.670.81.828.57.410.00931225500/D
47/0.851.02.035.54.610.00921915500/D
67/1.041.02.139.53.080.00782595500/D

26 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
270.57/0.300.81.821.036.00.0162500500/D
0.757/0.370.81.822.524.50.0142610500/D
17/0.400.81.823.018.10.0135665500/D
1.57/0.500.81.825.512.10.0115860500/D
2.57/0.670.81.828.57.410.00931270500/D
47/0.851.02.035.54.610.00921985500/D
67/1.041.02.139.53.080.00782700500/D

27 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
270.57/0.300.81.821.036.00.0162500500/D
0.757/0.370.81.822.524.50.0142610500/D
17/0.400.81.823.018.10.0135665500/D
1.57/0.500.81.825.512.10.0115860500/D
2.57/0.670.81.828.57.410.00931270500/D
47/0.851.02.035.54.610.00921985500/D
67/1.041.02.139.53.080.00782700500/D

28 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
280.57/0.300.81.822.036.00.0162535500/D
0.757/0.370.81.823.524.50.0142650500/D
17/0.400.81.824.018.10.0135710500/D
1.57/0.500.81.826.012.10.0115915500/D
2.57/0.670.81.830.07.410.00931350500/D
47/0.851.02.037.04.610.00922110500/D
67/1.041.02.241.53.080.00782885500/D

29 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
290.57/0.300.81.822.036.00.0162540500/D
0.757/0.370.81.823.524.50.0142660500/D
17/0.400.81.824.018.10.0135715500/D
1.57/0.500.81.826.012.10.0115930500/D
2.57/0.670.81.830.07.410.00931370500/D
47/0.851.02.037.04.610.00922145500/D
67/1.041.02.241.53.080.00782940500
Cvv Copper Control Cable Cvv-S Cvv-Swa
Cvv Copper Control Cable Cvv-S Cvv-Swa
Cvv Copper Control Cable Cvv-S Cvv-Swa
       
Mobile: +86 15037165923