China Factory Source Measure Unit Perovskite Solar Cells IV Curve Tracer Similar with Smu Keithley S2400 Source Meter Similar, Find details about China Source Meter, Source Meter Unit from China Factory Source Measure Unit Perovskite Solar Cells IV Curve Tracer Similar with Smu Keithley S2400 Source Meter Similar
Introduction
Wuhan Precise Instrument Co.,Ltd has been creating S series source meter for so many years.
The source meter function has high-precision, large dynamic range, digital touch screen, four-quadrant operation, collect and test input & output voltage and current, meanwhile, maximum output voltage 300V, and minimum output current 100pA.
Therefore, it is widely used in electrical characteristics tests.
Sourcemeter Applications
Semiconductor device test: Resistance, Diode, Transistor, MOSFET, SiC, GaN, etc .
Energy and efficiency test: LED / AMOLED, Solar cells, DC-DC converters, etc .
Sensor characteristic test: Resistivity, Hall effect, etc .
Organic material test: Electronic ink, Printed electronic technology, etc .
Nanomaterial test: Graphene, Nanowires, etc .
Four quadrant diagram
S100 S200 S300
Capabilities
Max output power | 30W, four quadrant source or sink operation |
Source/sink limits | ±30V (≤1A), ±300V (≤100mA), |
±1.05A (≤30V), ±105mA (≤300V) | |
Overrange | 105% of range, source and measure |
On-load capacitance | <22nF |
Noise (20MHz) | 2mV RMS, <20mV Vp-p |
Voltage guard | Output impedance 1 kΩ, Deflection-Voltage<80uV |
Max sampling rate | 1000 sample/s |
Trigger | I/O |
Communication Interface | RS-232,GPIB,LAN |
Power supply | AC100V~240V 50/60Hz |
Temperature coefficient | 25±10 ºC |
Length,Width and Height | 425mm L x 255mm W x 106mm H |
Weight | 5KG |
Warranty | 1 year |
Voltage | Source | Measure | ||
Range | Programming resolution | Accuracy±(% rdg.+ volts) | Programming resolution | Accuracy±(% rdg.+ volts) |
300mV | 30uV | 0.1%±300uV | 30uV | 0.1%±300uV |
3V | 300uV | 0.1%±500uV | 300uV | 0.1%±500uV |
30V | 3mV | 0.1%±3mV | 3mV | 0.1%±3mV |
300V | 30mV | 0.1%±30mV | 30mV | 0.1%±30mV |
Current | Source | Measure | ||
Range | Programming resolution | Accuracy±(% rdg.+ A) | Programming resolution | Accuracy±(% rdg.+ A) |
100nA | 10pA | 0.1%±0.5nA | 10pA | 0.1%±0.5nA |
1uA | 100pA | 0.1%±3nA | 100pA | 0.1%±3nA |
10uA | 1nA | 0.1%±5nA | 1nA | 0.1%±5nA |
100uA | 10nA | 0.1%±50nA | 10nA | 0.1%±50nA |
1mA | 100nA | 0.1%±300nA | 100nA | 0.1%±300nA |
10mA | 1uA | 0.1%±5uA | 1uA | 0.1%±5uA |
100mA | 10uA | 0.1%±20uA | 10uA | 0.1%±20uA |
1A | 100uA | 0.1%±2mA | 100uA | 0.1%±2mA |
SMU Detailed Photos
Company Profile