China Meditech External CO2 Monitor Capnoxi with Nellcor Pulse Oximeter Adult, Pediatric or Neonate., Find details about China Capnography Device, Capnography Waveforms from Meditech External CO2 Monitor Capnoxi with Nellcor Pulse Oximeter Adult, Pediatric or Neonate.
CapnOxi sidestream EtCO2(End Tidal CO2) sensor. It does not occupy any host space and connects to host just with one eight-pin plug. Capnoxi for measurement of instantaneous CO2 concentration, respiration rate, end-tidal CO2 concentration, inspired CO2 concentration, inspiration time and expiration time. It is generally used with patient monitor and anesthetic machine. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric and infant patients; Patients undergoing procedural sedation; And short- term monitoring of intubated patients. |
External CO2 monitor Capnoxi Sidestream plug-in etco2 sensor State-of-the-art Non-dispersive infrared (NDIR) technology, dual wavelength, no moving parts Breath-by-breath CO2 monitoring Isolated design of gas & electronic Sample rate low to 50 mL/min, microstream Barometer pressure and temperature compensation Range calibration in 0 15% by manufacturer Fast warmup time ensures full accuracy within 5 minutes Oxygen, N2O and anesthetic compensation for accurate measurement Low power consumption less than 1.5W Long life time pump from Germany company Fully compatible with Respronics Loflo sensor module |
Transducer Type | Sidestream EtCO2 sensor | |
Sample Rate | 50 mL/min, ± 10mL/min. Microstream | |
Principle of Operation | Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts | |
Initialization Time | Capnogram displayed in less than 5 seconds Reaching full specifications within 5 minutes. | |
CO2 Measure Range | 0 --114 mmHg | |
0-15% | ||
0 --15.2kPa | ||
CO2 Resolution | 0.1 mmHg | 0 to 50 mmHg |
0.25 mmHg | 50 to 114 mmHg | |
CO2 Accuracy | 0-40 mmHg | ± 2mmHg |
40-114 mmHg | ± 5% of reading | |
Respiratory Rate | Range | 2 to 120 Breaths Per Minute (BPM) |
Accuracy | ± 1 breath | |
Calibration | No routine user calibration required | |
Compensation | Automatic Barometer Pressure 400 - 800 mmHg. User selectable O2 / N2O compensation. | |
Voltage Requirements | 5.0 VDC ± 5% | |
Power Consumption | Less than 1.5 Watts typical. | |
Temperature and Humidity | Operating: 0 to 50 degree Celsius, 10 to 90% RH, non-condensing | |
Storage: -40 to 70 degree Celsius, < 90% RH, non-condensing | ||
Data Interface | RS232, bi-directional, 19200 baud rate, standard N-8-1. | |
Fully compatible with Respironics LoFlo communication protocol | ||
CPT protocol available | ||
Phasein protocol available | ||
Artema protocol available | ||
User-define protocol available | ||
Data Output | CO2 gas concentration (mm Hg), End-tidal CO2, Inspired CO2, Respiratory Rate, Automatic barometric pressure compensation. |
Standard: CO2 Sample Line. ......... 1Pcs Nasal Tube .................. 1Pcs Power Adapter .............. 1Pcs Water-trap Column ......... 1Pcs Airway Adapter ............. 1Pcs |