China Hrsc-50 Switching Power Supply 90-264VAC to DC 5V 12V 24V 48V 50W, Find details about China Power Supply, Switching Power Supply from Hrsc-50 Switching Power Supply 90-264VAC to DC 5V 12V 24V 48V 50W
MODEL | HRSC-50-5 | HRSC-50-12 | HRSC-50-24 | HRSC-50-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V |
VOLTAGE TOLERANCE ( Note.3) | ±1% | ±1% | ±1% | ±1% | |
RATED CURRENT (Note.4) | 8A | 4.2A | 2.1A | 1.1A | |
CURRENT RANGE | 0-8A | 0-4.2A | 0-2.1A | 0-1.1A | |
RATED POWER | 40W | 50.4W | 50.4W | 52.8W | |
VOLTAGE ADJUST RANGE | 4.75-5.5V | 10.8-13.2V | 21.6-26.4V | 42-52.8V | |
RIPPLE & NOISE (Note.2) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
SETUP, RISE, HOLD UP TIME (Typ.) | 1000ms,20ms,100ms/230VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90~264VAC 47~63 Hz; 125~370VDC | |||
AC CURRENT (Typ.) | 0.8A/230VAC | ||||
EFFICIENCY (Typ.) | 81% | 86% | 88% | 90% | |
INRUSH CURRENT (Typ.) | 36A/230V | ||||
LEAKAGE CURRENT | <2mA/240VAC | ||||
PROTECTION | OVERLOAD | 110%~150% | |||
hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | hiccup mode, recovers automatically after fault condition is removed | ||||
5.75~6.75V | 13.8~16.2V | 27.6~32.4V | 55.2-64.8V | ||
SHORT CIRCUIT | hiccup mode, recovers automatically after fault condition is removed | ||||
ENVIRONMENT | WORKING TEMP, HUMIDITY | -10ºC~+50ºC;20%~90 %RH | |||
STORAGE TEMP, HUMIDITY | -20ºC~+85ºC;10%~95 %RH | ||||
VIBRATION RESISTANCE | 10~500Hz,2G 10min./ 1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY | WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
INSULATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||
EMC | SAFETY STANDARDS | Compliance to TUV EN60950 | |||
EMC EMISSION | Compliance to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11; EN55024 | ||||
OTHERS | WEIGH | 0.23Kg | |||
PACKING | 60pcs/14.5Kg/1.13CUFT | ||||
NOTE |
|