China Hrsc-100-5 Switching Power Supply Input 90-264VAC to DC 100W 5V 16A, Find details about China Power Supply, AC to DC Power Supply from Hrsc-100-5 Switching Power Supply Input 90-264VAC to DC 100W 5V 16A
MODEL | HRSC-100-5 | HRSC-100-12 | HRSC-100-24 | HRSC-100-48 | ||
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V | |
VOLTAGE TOLERANCE ( Note.3) | ±1% | ±1% | ±1% | ±1% | ||
RATED CURRENT( Note.4) | 16A | 8.3A | 4.2A | 2.1A | ||
CURRENT RANGE | 0-16A | 0-8.3A | 0-4.2A | 0-2.1A | ||
RATED POWER | 80W | 99.6W | 100.8W | 100.8W | ||
VOLTAGE ADJUST RANGE | 4.75-5.5V | 10.8-13.2V | 21.6-26.4V | 42-52.8V | ||
RIPPLE & NOISE (Note.2) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | ||
SETUP, RISE, HOLD UP TIME (Typ.) | 1000ms,20ms,30ms/230VAC at full load | |||||
at full load | VOLTAGE RANGE | 90~264VAC 47~63 Hz; 125~370VDC | ||||
AC CURRENT (Typ.) | 1.5A/230VAC | |||||
EFFICIENCY (Typ.) | 82% | 87% | 88% | 90% | ||
INRUSH CURRENT (Typ.) | 36A/230V | |||||
LEAKAGE CURRENT | <2mA/240VAC | |||||
PROTECTION | OVERLOAD | 110%~150% | ||||
hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | hiccup mode, recovers automatically after fault condition is removed | |||||
5.75~6.75V | 13.8~16.2V | 27.6~32.4V | 55.2-64.8V | |||
SHORT CIRCUIT | hiccup mode, recovers automatically after fault condition is removed | |||||
ENVIRONMENT | WORKINGTEMP,HUMIDITY | -10ºC~+50ºC;20%~90 %RH | ||||
STORAGETEMP,HUMIDITY | -20ºC~+85ºC;10%~95 %RH | |||||
VIBRATION RESISTANCE | 10~500Hz,2G 10min./ 1cycle, 60min. each along X, Y, Z axes | |||||
SAFETY | WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
INSULATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
EMC | SAFETY STANDARDS | Compliance to TUV EN60950 | ||||
EMC EMISSION | Compliance to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11; EN55024 | |||||
OTHERS | WEIGH | 0.41Kg | ||||
PACKING | 45pcs/18.8Kg/1.22CUFT | |||||
NOTE |
|