China 10kv5a High Voltage AC to DC Power Supply, Find details about China Linear DC Power Supply, Linear Power Supply from 10kv5a High Voltage AC to DC Power Supply
Electrical Characteristics | |
1. Input,Output | Input: Three-phase 380Vac±10% 50Hz±10% Output:DC C.C. and/or C.V. Max output: 10000V5A (Grounding: two optional modes, default configuration is negative high-voltage, positive grounding) 1. Positive high-voltage, negative grounding 2. Negative high-voltage, positive grounding |
2. Accuracy (C.V.) | Line regulation: ≤0.1% Of the rated value (output voltage change ratio under input ±10% change) Stability: during 8 hrs≤0.3% of the rated value (output voltage change ratio due to 8 hours continuously working) Temp. coeff.offset: ≤0.04% of the rated value/ºC(output voltage change ratio due to environment temperature changes) Load regulation(load 0~100%): ≤0.3% of the rated value (output voltage change ratio due to output current change from 0 to rated value) |
3. Accuracy (C.C.) | Line regulation: ≤0.1% Of the rated value (output current change ratio under input ±10% change) Stability: during 8 hrs≤0.3% of the rated value(output current change ratio due to 8 hours continuously working) Temp. coeff.offset: ≤0.04% of the rated value/ºC(output current change ratio due to environment temperature changes) Load regulation(load 0~100%): ≤0.3% of the rated value (output current change ratio due to output voltage change from 0 to rated value) |
4. Ripple +noise(r.m.s) | Positive high-voltage, negative grounding: ≤0.2% of the rated value+10mV (80%~100% rated output) Negative high-voltage, positive grounding: ≤0.1% of the rated value+10mV (80%~100% rated output) |
5. Programming output voltage | Adjustable (0~rated value) or CV |
6. Programming output current | Adjustable (0~rated value) or CC |
7. Adjusting mode | 10-turn Potentiometer Key button (optional) |
8. Protections function | Auto-protection when over voltage/over current/lack phase |
9. Short protection | Auto-tripping when short-circuit |
10. Working mode | Withstand long-term continual working at full load |
11. Read output | Digital LED |
12. Display precision | 10V, 0.01A |
13. Display accuracy | ≤±1%±1digit (range:5%~50% of the rated value) ≤±0.5%±1digit (range:50%~100% of the rated value) |
14. Load characteristic | on demand |
15. Operating condition | Location: indoor use only Temperature:-20°C ~ +40°C Humidity:≤80% |
16. Spare parts | Company standard (fuse * 1pc, high-voltage output line * 1pc, operation manual * 1pc) |