High Accuracy Pressure Snesor for Tank ( JC610 -25)

China High Accuracy Pressure Snesor for Tank (JC610-25), Find details about China High Accuracy Pressure Snesor, Pressure Snesor for Tank from High Accuracy Pressure Snesor for Tank (JC610-25)

Model NO.
JC610-25
Customized
Customized
Material
Stainless Steel
Trademark
JC
Transport Package
Standard Exporting Carton
Origin
Nanjing, China
Model NO.
JC610-25
Customized
Customized
Material
Stainless Steel
Trademark
JC
Transport Package
Standard Exporting Carton
Origin
Nanjing, China
High Accuracy Pressure Snesor for Tank (JC610-25)

JC610-25 High Accuracy Pressure Sensor for Tank Overview:

JC610-25 high accuracy pressure sensor for tank is encapsulated in a stainless steel case through assembly and commissioning by use of advanced foreign silicon piezoresistive sensitive elements. Both the case and interface materials are made of stainless steel. The medium is of good compatibility, with stable & reliable performance and high accuracy. The gasket is sealed on the end face.

JC610-25 High Accuracy Pressure Sensor for Tank Features:
* Measuring range:-0.1MPa~0~10kPa...70MPa
* Total stainless steel construction
* Standard thread pressure-leading measuring method
* Power supply at constant-current and -voltage source  
* Laser resistance-trimming compensation zero and full-scale temperature performance
* Using solid-state piezoresistive pressure sensor, with high reliability and high accuracy.
* Small size, diversified and optional structural forms
High Accuracy Pressure Snesor for Tank (JC610-25)

JC610-25 High Accuracy Pressure Sensor for Tank Application:
* Pressure measurement of various dynamic & static
* Automotive electronics gases and liquid media
* Ventilation system
* Aerospace
* Pneumatic control
* Industrial measurement

High Accuracy Pressure Snesor for Tank (JC610-25)

Technical Parameters:
Measuring range-0.1MPa~0~10KPa...70MPa
Overload capacityTwo times of the measuring scale for overpressure
Power supply1.5mA DC10~24V DC constant voltage
Zero output0±2 mV DC0±2 mV DC
Full scale output70~110mVDC70~110mV DC
Measuring MediaThe gas or liquid compatible with 316 stainless steel
Overall accuracy (Linearity, repeatability 
and hysteresis)
±0.1%FS±0.25%FS±0.4%FS
Long-term stability≤±0.1%FS/year
Operating temperature-40~85ºC 
Compensation temperature-10~50ºC 
Temperature performanceZero temperature coefficient: ±0.02%FS/ºC ( Typical value );  ±0.04%FS/ºC ( Maximum value )
Sensitivity temperature coefficient: ±0.02%FS/ºC ( Typical value );  ±0.04%FS/ºC ( Maximum value )
Thermal hysteresis±0.1%FS/ºC ( Typical value )
MaterialsEnclosure: Stainless steel 1Cr18Ni9TMembrane: Stainless steel 316L
Cable: polyvinyl chloride cableSealing:Fluorine rubber sealing ring
Electrical connectionPG7 cable connection
Response Time(10%~90%)≤1 ms
ResolutionInfinitely small ( theoretic ), 1/100000 ( normal )
Insulation resistance100MΩ / 500VDC
Enclosure protection classIP67 ( Cable type )IP65 ( Socket type )
WeightAbout 250g
VibrationNo change under 10gRMS, 20 ~ 2000Hz
Impact100g,11 milliseconds

Ordering Information:
JC610-25High Accuracy Pressure Sensor for Tank
 Pressure typeGauge pressure ( G may not be indicated )
Absolute pressure ( A )
Sealed reference pressure ( S )
 Range( 0~ X  KPa or MPa)
 CodeOverall accuracy ( linearity + repeatability + hysteresis )
1±0.4%FS
2±0.25%FS
3±0.1%FS
 CodePower supply
D110~24VDC constant voltage
D21.5mA DC constant current
 CodeSignal output
V10±2mV~90±20mV
 CodeAdditional functions
F1M20x1.5 external thread
F2G1/4 external thread
F0Special
W1Cable type(IP67,2m)
W2Aerial socket type(IP65)
PFlush diaphragm type
EIntrinsically safe explosion-proof type Ex iaIICT5
JC610-25(0~200KPa)  -1    -D1    -V1    -F2   -W1   -E        High Accuracy Pressure Sensor for Tank

Tips for Type Selection
* When installing the flush diaphragm product on the site, adopt the correct sealing means to prevent any influence on product stability by installation stress.
* The Company may, according to users' requirements, provide products at 70MPa or higher pressure or at a wide temperature compensation range.
* As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex ia II CT5 denotes that power source must be supplied via safety barrier.
* For other special requirements, please discuss with us.  

High Accuracy Pressure Snesor for Tank (JC610-25)High Accuracy Pressure Snesor for Tank (JC610-25)

About Jiucheng
High Accuracy Pressure Snesor for Tank (JC610-25)

Qualification and Certificate:
High Accuracy Pressure Snesor for Tank (JC610-25)

High Accuracy Pressure Snesor for Tank (JC610-25)


Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
High Accuracy Pressure Snesor for Tank (JC610-25)

Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.
High Accuracy Pressure Snesor for Tank (JC610-25)