China 100 Psi Pressure Transducer Sender Sensor with Connector
Parameter | Value | Units | Notes | ||||||
General | |||||||||
Pressure Range | -0.01-0 -1000 | Bar | 1bar=14.5Psi | ||||||
Overpressure | 1.5xFS | bar | |||||||
Environmental | |||||||||
Operating Temperature Range | -20 to +85 | oC | -4 °F to 185 °F | ||||||
Compensated Temperature Range | -10 to +70 | oC | 14 °F to 158 °F | ||||||
Storage Temperature Range | -40 to +125 | oC | -40 °F to 257 °F | ||||||
Vibration | 10 | g | 20 to 2000Hz | ||||||
Shock | 100 | g | 10ms | ||||||
Cycles | 10x106 | cycles | |||||||
Electrical @ 25°C(77°F) | |||||||||
Output Signal | 4...20mA | 0...5Vdc | 1...5Vdc | 0...10Vdc | 0.5. 4.5Vdc(ratiometric) | ||||
Power Supply(Vs) | 12. 36Vdc | 12. 36Vdc | 12. 36Vdc | 15. 36Vdc | 5Vdc | ||||
Load Resistance | <(Vs-12)/0.02A (For current output), >10kΩ (For voltage output) | ||||||||
Insulation Resistance | 100MΩ @50Vdc | ||||||||
Physical Specifications | |||||||||
Media Compatibility | All media compatible with 316L stainless steel | ||||||||
Housing | 304 or 316 stainless steel | ||||||||
Diaphragm | 316L stainless steel | ||||||||
Seal Ring | Viton or NBR | ||||||||
Oil Filling | Silicone oil | ||||||||
Protection | IP65(Standard), IP68(only for cable outlet) | ||||||||
Net Weight | Approx.185g | ||||||||
Parameter | Minimum | Typical | Maximum | Units | Notes | ||||
Performance | |||||||||
Accuracy | 0.1 | 0.25 | 0.5 | %FSO | 1,2 | ||||
Temp Coeff - Zero | ±0.75 | ±1.5 | %FSO | 3 | |||||
Temp Coeff - Span | ±0.75 | ±1.5 | %FSO | 3 | |||||
Long-Term Stability | ±0.2 | ±0.3 | %FSO/year | 1 |
Option1: Model | ||||||||
QYB100 | Piezoresistive Pressure Transmitter | |||||||
Option2: Pressure Ranges | ||||||||
N001 | -1...0bar | 0016 | 0 1.6bar | 0600 0...60bar | ||||
N002 | -0.35...0bar | 0025 | 0 2.5bar | 1000 0...100bar | ||||
N003 | -0.2...0bar | 0040 | 0...4bar | 2500 0...250bar | ||||
0001 | 0 ...0.1bar | 0060 | 0...6bar | 4000 0...400bar | ||||
0003 | 0 ...0.35bar | 0100 | 0...10bar | 6000 0...1000bar | ||||
0007 | 0 ..0.7bar | 0160 | 0...16bar | Cxxx Customized range | ||||
0010 | 0...1bar | 0250 | 0...25bar | |||||
Option3: Pressure Type | ||||||||
G | gauge | |||||||
A | absolute | |||||||
S | sealed gauge | |||||||
Option4: Output Signal | ||||||||
42 | 4...20mA | |||||||
05 | 0...5VDC | |||||||
15 | 1...5VDC | |||||||
10 | 0...10VDC | |||||||
45 | 0.5...4.5VDC | |||||||
Option5: Accuracy | ||||||||
02 | 0.25%FSO | |||||||
05 | 0.5%FSO | |||||||
Option6: Electrical Connection | ||||||||
D | Connector DIN43650 | |||||||
H | Hirschmann cable outlet,length=1.5m | |||||||
C | Cable outlet with PVC-cable,length=1.5m | |||||||
M | M12x1, 4-pin | |||||||
Option7: Mechanical Connection | ||||||||
M2 | M20x1.5(male) N1 1/4NPT(male) | |||||||
G4 | G1/4(male) F4 G1/4(female) | |||||||
G2 | G1/2(male) Nx Customized | |||||||
QYB100 | 0010 | G | 42 | 02 | D | G4 | Examples of Ordering Code: QYB-40S-0010-G-42-02-D-G4 |