10L Aluminum Gas Tank Medical Oxygen Gas Cylinder

China 10L Aluminum Gas Tank Medical Oxygen Gas Cylinder, Find details about China Oxygen Cylinder, Oxygen Gas Cylinder from 10L Aluminum Gas Tank Medical Oxygen Gas Cylinder

Model NO.
MB159-10.0
Water Capacity
10L
Weight
8.8kg
Design Wall Thickness
8cm
Working Pressure
15MPa
Test Pressure
35MPa
Oxygen Supply Time
1400min
Flow Regulation Range
0-15L/Min
Trademark
SEFIC
Transport Package
Put Into Carton, Then Packed by Wooden Box
Specification
GB11640/BS5045
Origin
Shanghai, China(Mainland)
HS Code
7613001000
Model NO.
MB159-10.0
Water Capacity
10L
Weight
8.8kg
Design Wall Thickness
8cm
Working Pressure
15MPa
Test Pressure
35MPa
Oxygen Supply Time
1400min
Flow Regulation Range
0-15L/Min
Trademark
SEFIC
Transport Package
Put Into Carton, Then Packed by Wooden Box
Specification
GB11640/BS5045
Origin
Shanghai, China(Mainland)
HS Code
7613001000

Medical Oxygen Gas Cylinder

1.Application scope:

1, it can be used in the treatment of cardiovascular, respiratory and heart disease, other severe hypoxia symptoms such as gas poisoning and other illnesses.
2, It can improve the physical condition of oxygen to achieve the purpose of health care. It is suitable for the people in different levels of hypoxia, such as the elderly with poor physical fitness, pregnant women, senior students. It is also used for eliminating fatigue and recovering physical function after we consumed heavy physical or mental power.
3, It can reduce and delay the onset of disease. It is useful for delaying the aging and onset of the human heart, brain, lung, spleen, liver, kidneys and other vital organs.

10L Aluminum Gas Tank Medical Oxygen Gas Cylinder
10L Aluminum Gas Tank Medical Oxygen Gas Cylinder

10L Aluminum Gas Tank Medical Oxygen Gas Cylinder
10L Aluminum Gas Tank Medical Oxygen Gas Cylinder


2.Product parameters:

TypeOutside 
diameter
(mm)
Water 
capacity
(L)
Weight
(kg)
Design wall 
thickness
(mm)
Working 
Pressure
(Mpa)
Test 
pressure
(Mpa)
Oxygen 
Supply Time
(min)
Flow Regulation Range
(L/min)
MB108-2.0108*34022.25.515352800-7
MB120-2.8120-3922.82.96.11535390
MB120-3.2120*4373.23.36.11535420
MB140-4.0140*41044.27.11535560
MB140-6.3140*6056.35.97.11535900
MB159-6.3159*4956.36.4815359000-15
MB159-10.0159*730108.8815351400

Note: 1) Highest oxygen storage pressure: 15 MPa.

2) Using time: Calculating by the working pressure (10-15) MPa flow rate of 1 liter / minute. It does not consider the oxygen allowance in the oxygen bottle

Luxury beautiful advanced technologyOperation is simple, safe and reliable

10L Aluminum Gas Tank Medical Oxygen Gas Cylinder
 

INSTRUCTIONS:

10L Aluminum Gas Tank Medical Oxygen Gas Cylinder

How to oxygen: (will you use the model of the oxygen supply and control products to read carefully)

The oxygen bottles, humidification flow cup, oxygen inhalation tube connected open oxygen handwheel (see Figure 3), slowly open the flow hand wheel (see Figure 4), flow meter and the flow meter to work (water bubbles), corresponding to the float flow meter pointer indicating scale or flowmeter calibration is how much l / min oxygen flow. The ear hanging in the ear, nasal congestion into the nasal cavity, began to oxygen, each time for 10-20 minutes, no more than 60 minutes a day is appropriate. The rescue of critically ill patients should be properly adjusted according to the condition of high oxygen flow, generally 4-5 L / min. After the oxygen, oxygen should be closed when the pressure gauge pointer to the wheel, "0" and then close the flow scale after the handwheel.

MATTERS NEEDING ATTENTION:

1, is strictly prohibited without permission to disassemble, oxygen supply device failure, please send the production unit or repair station maintenance. 
2, no other gas filling.
3, oxygen is prohibited oil, prohibit the impact, to stay away from fire, inflammable and explosive materials, to avoid contact with corrosive gases, liquids, and can not be used strong direct sunlight.
4, oxygen filling, the pressure does not allow more than 15 mpa.
5, according to the national standard, need to carry on an oxygen bottle / cylinder pressure test every three years. When testing is required, please contact the local pressure vessel inspection unit.

 

3.Contact us:

Manager: David 
   Tel: 0086-21-6601 9677 
M.P: 0086-180 1766 2601  Fax: 0086-21-6601 9679 
    Web: cnsefic.en.made-in-china.com
ADD: NO.6598., Hutai Road, Baoshan district Shanghai, China 201908