China Online Tower UPS 1-3kVA Uninterrupted Power Supply, Find details about China Smart UPS, Online Smart UPS from Online Tower UPS 1-3kVA Uninterrupted Power Supply
General Features
Online double conversion,
Wide input voltage range (110~300Vac)
Input power factor 0.99
Output power factor 0.9
Maximum 12A charger for long-run models
Charging current can be set by LCD(Long run unit)
50Hz/60Hz frequency converter mode
Emergency power off function (EPO)
ECO mode operation for energy saving
Generator compatible
SNMP + USB + RS232 multiple communications
Smart battery charger design for optimized battery performance
Selectable output voltage: 200,208,220,230,240Vac
MODEL | UDC9101S / UDC9101H | UDC9102S / UDC9102H | UDC9103S / UDC9103H | |||||||||||
Capacity (VA/Watts) | 1000VA / 900W | 2000VA / 1800W | 3000VA / 2700W | |||||||||||
Phase | Single phase with grounde with ground | |||||||||||||
INPUT | ||||||||||||||
Nominal Voltage | 200/208/220/230/240Vac | |||||||||||||
Operating voltage range | Lower limit of input voltage | 160Vac±5% @100%~80%load 140Vac±5% @80%~70%load 120Vac±5%@70%~60%load 110Vac±5%@60%~0%load (Ambient temp. <35ºC) | ||||||||||||
Lower limit of input voltage | 175Vac±5% @100%~80%load 155Vac±5% @80%~70%load 135Vac±5% @70%~60%load 125Vac±5% @60%~0%load(Ambient temp. <35ºC) | |||||||||||||
Upper limit of input voltage | 300Vac±5% | |||||||||||||
Upper comeback voltage from bypass mode to normal mode | 290Vac±5% | |||||||||||||
Input Voltage Range | 55~150Vac or 110~300Vac @ 60% load, 80~145Vac or 160~300Vac @ 100% load | |||||||||||||
Operating frequency range | 40~70Hz | |||||||||||||
Power Factor | 0.99 | |||||||||||||
Generator input | Support | |||||||||||||
OUTPUT | ||||||||||||||
Output Voltage | 200/208/220/230/240Vac | |||||||||||||
Power Factor | 0.9 | |||||||||||||
Voltage Regulation | ±1% | |||||||||||||
Frequency | Line mode (Synchronized range) | 47~53Hz or 57~63Hz | ||||||||||||
Bat. mode | (50/60±0.1)Hz | |||||||||||||
Crest Factor | 3:1 | |||||||||||||
Harmonic Distortion (THDv) | ≤3% THD (Linear load) | |||||||||||||
≤6% THD (Non-linear load) | ||||||||||||||
Waveform | Pure Sinewave | |||||||||||||
Transfer Time | AC mode <->Batt. Mode | Zero | ||||||||||||
Inverter <-> Bypass | 4ms(Typical) | |||||||||||||
EFFICIENCY | ||||||||||||||
AC Mode | 88% | 92% | 92% | |||||||||||
Battery Mode | 85% | 86% | 87% | 88% | 89% | 90% | ||||||||
BATTERY | ||||||||||||||
Battery Type | 12V9AH | Depends on the capacity of external batteries | 12V9AH | Depends on the capacityof external batteries | 12V9AH | Depends on the capacityof external batteries | ||||||||
Numbers | 2 | 2 | 3 | 4 | 4 | 6 | 6 | 6 | 8 | |||||
Backup time | Long run unit depends on the capacity of external batteries | |||||||||||||
Typical recharging time(Standard modle) | 4 hours recover to 90% capacity | |||||||||||||
Charging voltage | 27.4/41.1Vdc±1% | 27.4/41.1Vdc±1% | 41.0Vdc±1% | 54.7Vdc±1% | 54.7Vdc±1% | 82.1Vdc±1% | 82.1Vdc±1% | 82.1Vdc±1% | 109.4Vdc±1% | |||||
Charging current(max.) | 1.0A | 12A max,can be set by LCD | 1.0A | 12A max,can be set by LCD | 1.0A | 12A max,can be set by LCD | ||||||||
SYSTEM FEATURES | ||||||||||||||
Line mode Battery mode | Ambient temp.<35ºC | 105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal | ||||||||||||
35ºC ºC | 105%~110%: UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal >110%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal | |||||||||||||
Short circuit | Hold whole system | |||||||||||||
Overheat | Line mode: Switch to bypass; Backup mode: Shut down UPS immediately | |||||||||||||
Battery low | Alarm and switch off | |||||||||||||
EPO (optional) | Shut down UPS immediately | |||||||||||||
Audible & Visual alarms | Line failure, Battery low, Over load, System fault | |||||||||||||
Communication interface | USB (or RS232), SNMP card (optional), Relay card (optional) | |||||||||||||
PHYSICAL | ||||||||||||||
Dimension W×H×D (mm) | 144×209×293 | 144×209×293 | 144×209×293 | 144×209×399 | 144×209×399 | 144×209×399 | 191×337×460 | 144×209×399 | 144×209×399 | |||||
Net Weight (kg) | 9.8 | 4 | 4.1 | 17 | 6.7 | 6.8 | 27.6 | 7.3 | 7.4 | |||||
ENVIRONMENT | ||||||||||||||
Operating temperature | 0~40ºC | |||||||||||||
Storage temperature | -25ºC~55ºC | |||||||||||||
Humidity range | 20~90% RH @ 0~40ºC (Non-condensing) | |||||||||||||
Altitude | <1500m | |||||||||||||
Noise Level | Less than 50dBA @ 1 Meter | |||||||||||||
STANDARDS | ||||||||||||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||||||||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |