Seven Manifold Valve for Ivd Medical/Laboratory/Environmental Industry Application

China Seven Manifold Valve for Ivd Medical/Laboratory/Environmental Industry Application, Find details about China Manifold Valve, Exhaust Valve from Seven Manifold Valve for Ivd Medical/Laboratory/Environmental Industry Application

Model NO.
1371-22-EMU/5N
Pressure
-70 Kpa ~ 0.3 MPa
Valve Structure
Direct Action Diaphragm Structure
Power Supply
DC Solenoid Valve
Usage
Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Medical Device Usage
Size
20.5*42.5*58.2 mm
Voltage
24V
Power
4.2W
Orifice
2mm
Trademark
Keyto
Transport Package
Bulk Package
Specification
CE, RoHS
Origin
China
HS Code
8481804090
Model NO.
1371-22-EMU/5N
Pressure
-70 Kpa ~ 0.3 MPa
Valve Structure
Direct Action Diaphragm Structure
Power Supply
DC Solenoid Valve
Usage
Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Medical Device Usage
Size
20.5*42.5*58.2 mm
Voltage
24V
Power
4.2W
Orifice
2mm
Trademark
Keyto
Transport Package
Bulk Package
Specification
CE, RoHS
Origin
China
HS Code
8481804090
1 .Production Overview
The 13X1-2 series is a family of diaphragm solenoid valve with manifold, and its mainly
function is to switch on and switch off the liquid. These series have multiple option types, which
can be customized with different number of ports and they are suitable for different reagents in
different condition. It's a high precision, low cost and maintenance-free solenoid valve and its life
cycle is more than 2 million.
.
 
1.1.Characteristics Of 13X1-2 Series
Customized: solenoid valve manifold can be customized with different number of ports,
arrangement method and mounting ports according to customers' requirement.
Small dead volume: no dead volume inside the solenoid valve body
Multiples option for wetted material:
1. Body material:PTFE,PVDF,POM,PEI,PMMA
2. Seal material:EPDM, FKM,FFKM
Long lifetime, good performance.

1.2.Words Definition
The coefficient of variation (CV)
It is remarked as CV, but in China we mark it as KV. They are both non-dimensional
parameters and replaceable. CV means the liquid flow capability of elements. In actual design and
use, it must calculate to a flow dimensional parameter as application condition.
 
qv --The actual flow of medium, unit: gal/min;
0 --The density of water under 60F , 0 =1 / g cm 3 ;
P0 --A constant differential pressure of element,
 
,--The actual pressure drop of the tested element between inlet and outlet.
When it replaced as common physical dimension parameter in China, then:
Cv=0.03, means under the condition of 25ºC, 50KPa, the flow of component is 5.1ml/s.
Response Time (T)
Input air/water at 0.25MPa and maximum working pressure drop from inlet port, input rated
control electrical signal to make the tested solenoid valve open and close, then we'll get the
change of outlet pressure which we can measure from pressure sensor. At the same time, we'll
get the lapse of time which starts from power on/off to rise to 90% of max pressure (normally Focus on precision fluid control systems
G-1301-00(2.0) 3 closed valve) and drop to 10% of max pressure (normally open valve) by quick response time
measure devise. Repeatedly test several times and take the average valve as the power on
response time and the power off response time.
As engineering experience, it is the design critical value that response time above 50ms. The
aspiration of valve may not stable. Therefore, the response time is not beyond 50ms within
nominal lifetime.
In addition, there is a response time at current method in this industry. The change of circuit
leads to current change, according to the action of solenoid valve. The response time T1, T2 at
current method is normally less than the response time(T) which measured by air flow method.
Seal Capability
Pressure strengthen (outside leakage)
Solenoid valve powers on, the outlet is close, and the inlet water under condition of 5ºC~40ºC
and nominal pressure is 1.5 times. Then ensure all connector won't leak within 1min.
Sealing (inside leakage)
For two normally closed branches, give one port pressures; put the other port into water.
Under the nominal pressure, there is no bubble come out in 1min.

Specification: 
Structure 
Valves alinement
Type2/2-way,N.C
No.Of Ports 
2(N.O. port) +1(option air hole) +X (option branch), X=2, 3, …
Orifice Diameter 2.0mm
Coefficient Of Variation (CV)  0.03
Mediums
Water, air, weak acid and base corrosive
(Material will be decided based on medium. If strong acid and base
corrosive request, please contact Keyto.)
Operating Temperature5ºC~50ºC
Operating Pressure(in - out) -70 Kpa ~ 0.2MPa
Leakage Rate 0
Response Time<30ms
Dead Volume 0
Voltage ToleranceDC12V,24V
Fluctuation Of VoltageFrom-10% to+10%
Power Consumption 4.2W
Type of coil insulationB
Wight 80g

Photo:
Seven Manifold Valve for Ivd Medical/Laboratory/Environmental Industry Application