China High and Low Temperature Alternating Test Chamber, Find details about China Environmental High Low Temperature Humidity, Test Chamber Temperature and Humidity from High and Low Temperature Alternating Test Chamber
Type | Inner size | Shape size |
H/HWHS-50L | 350×350×400mm | 885×850×1320mm |
H/HWHS-100L | 400×500×500mm | 935×1000×1420mm |
H/HWHS-150L | 500×500×600mm | 1035×1000×1520mm |
H/HWHS-225L | 500×600×750mm | 1060×1130×1700mm |
H/HWHS-408L | 600×800×850mm | 1135×1300×1800mm |
H/HWHS-500L | 700×800×900mm | 1235×1300×1850mm |
H/HWHS-800L | 800×1000×1000mm | 1435×1400×1950mm |
H/HWHS-1000L | 1000×1000×1000mm | 1535×1500×1950mm |
Temperature range | Range | -40~180ºC adjustable | |
fluctuation | ≤±0.3ºC | ||
deviation | ≤±2.0ºC | ||
Rate | Heating rate | +25ºC~ +150ºC, ≤40min(No-load nonlinear control) | |
Cooling rate | +25ºC~ -40ºC, ≤60min(No-load nonlinear control) | ||
Change rate | Heating 2ºC~3ºC/Min(No-load nonlinear control) | ||
Cooling 0.7ºC~1.6ºC/Min(No-load nonlinear control) | |||
Inner size | 750mm x 650mm x 450mm(W x L x H) | ||
Ship size | 1060×1130×1700mm(D×W×H) reference only | ||
Power | 220V±10%,50Hz±1 | ||
Heating power | 2KW | ||
Cooling power | 1KW | ||
Total power | 4KW | ||
Structure | Temperature chamber, temperature system. The refrigerating unit is one unit. | ||
Material composition | Outer wall material: cold rolled steel plate electrostatic double-sided spray plastic | ||
Inner wall material: SUS304 stainless steel plate | |||
Thermal insulation material: 120mm glass wool insulation layer | |||
structural strength | Load bearing capacity of test box: ≤50Kg (uniform load) | ||
Door | Single door | ||
Two silicone rubber sealing strips are used for the door frame of low greenhouse | |||
Window | Each door has a multi-layer observation window, and the observation window on the door is coated with heating to prevent condensation and frosting | ||
Condensate outlet hole | It has outlet holes for condensate water in the studio and condensate water in the unit | ||
Overflow hole | An overflow hole is arranged at the rear of the box body to facilitate the outflow of condensed water. | ||
Test hole | One cable hole of 50mm diameter with sealing plug and cover | ||
Control panel | Temperature control display, power switch | ||
Mechanical room | The mechanical room includes: refrigerating unit, connection and drainage device, distribution control cabinet, high and low temperature circulation fan, exhaust fan | ||
Distribution control cabinet | Cooling fan, switchboard, sample test terminals, RS-485 physical interface (optional), main power leakage circuit breaker |