Ce Certified Approved Bluetooth Handheld Pulse Oximeter

China Ce Certified Approved Bluetooth Handheld Pulse Oximeter, Find details about China Handheld Pulse Oximeter, Pulse Oximeter from Ce Certified Approved Bluetooth Handheld Pulse Oximeter

Model NO.
BM1000A
Cetificaties
Ce0123, ISO13485, SGS
Trust Us
with 10 Years Manufacturer
Trademark
BERRY
Transport Package
1 Box
Specification
CE0123
Origin
Shanghai
HS Code
90189090
Model NO.
BM1000A
Cetificaties
Ce0123, ISO13485, SGS
Trust Us
with 10 Years Manufacturer
Trademark
BERRY
Transport Package
1 Box
Specification
CE0123
Origin
Shanghai
HS Code
90189090
Handheld Palm Pulse Oximeter Oxymeter for Adult/ Neonatal Infant Pediatric
Ce Certified Approved Bluetooth Handheld Pulse OximeterCe Certified Approved Bluetooth Handheld Pulse OximeterCe Certified Approved Bluetooth Handheld Pulse OximeterCe Certified Approved Bluetooth Handheld Pulse OximeterCe Certified Approved Bluetooth Handheld Pulse Oximeter
Instruction
 
This Pulse Oximeter could be applied in the hospital's operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment. It is suitable for Adult, Pediatric, Infant(Neonatal).
 
Specification
Parameter: SpO2, Pulse
Display Format: LCD 
Battery: 2 standard 1.5V AAA alkaline batteries
SpO2 Range: 35-99% (Accuracy: ±2% at 70-99%)
Pulse Rate: 30-255bpm (Accuracy:±2% at 30-255bpm )
Power Consumption: Less than 60 mA.
Resolution: 1% for SpO2 and 1 BPM for Pulse Ratio.
Measurement Accuracy: ±2% in stage of 70%-99% for SpO2
Unspecified in stage of 35-69% for SpO2
Interference Resistance Capacity against Ambient Light: Deviation is smaller than ±1%
Packing: 1 piece per box, including 1 fingerclip, fingertip or disposable SpO2 sensor

If sample or small volume, welcome to check our aliexpress or ebay website for more special discount!
 

Contact us
 

Brief Introduction of company

 

 

Shanghai Berry Electronic Technology Co., Ltd is located in the beautiful,low carbon and environmental protection city Shanghai Caohejing Hi-Tech Park.

 

We are devoted to researching and developing,manufacturing and sales of medical electronic instrument in the monitor field. Our technology has reached the advanced level in domestic. And we have got important breakthrough on the non-invasive blood pressure calculation method, oxygen saturation detection, and multi parameter monitoring system,etc. After years of development, we have got good relationship with many customers.And the annual sales value reaches to tens of millions.The Berry product is in the leading level in this industry. In 2009, we have obtained the production license and product registration certificate that issued by Shanghai FDA. And in 2014, Berry passed the EN ISO 13485 quality system certification and CE certification by TÜV SÜD. And we got the FDA 510K in 2015. 

 

We have an extremely professional technical team.And the person who has bachelor degree accounts for more than 40% of the company's population.

 

Berry pays attention to product quality and has strict standard on R&D, production and quality control. We have many global advanced testing instruments like multi parameter test instrument, noninvasive blood pressure simulator, oxygen saturation simulator and other testing equipment. And we do testing strictly according the standard.

 

By adhering to the values of "consistently care for life", we are pursuing higher quality products and Constant innovation.


 
berrymedical.en.made-in-china.com
 
 
 
Company Name: Shanghai Berry Electronic Tech.,Ltd
Company Address: Unit C, 1 Floor, 7th Building, No.1188 Lianhang Road, Minhang District, Shanghai, China
 
 


Cetificates

 
ModelProductsStandard configuration
BM1000AHandheld pulse oximeterFinger clip SpO2 sensor
BM2000AWrist pulse oximeter
(with Bluetooth)
Soft silicone SpO2 sensor
BM2000BWrist pulse oximeterSoft silicone SpO2 sensor
BM1000BFingertip pulse oximeter
(with Bluetooth-OLED)
 
BM1000DFingertip pulse oximeter
(No Bluetooth-OLED)
 
BM1000CFingertip Pulse Oximeter
(with Bluetooth- No OLED)