China 40t85 Micro Limit Switch T85 5e4, Find details about China Micro Switch T85 5e4, 40t85 Micro Switch from 40t85 Micro Limit Switch T85 5e4
Item | Value | |
Operating Speed | 0.1mm~1m/s(Related with actuator forms) | |
Operating Frequency | Mechanical 60 cycles/min;Electrical 30 cycles/min | |
Insulation Resistance | >=100 MΩ (500VDC) | |
Contact resistance | <=30mΩ(Initial value) | |
Test Voltage | Between terminals of the same polarirty | AC1000V,50/60Hz,1min |
Between current-carrying metal,and ground(case),and between each terminal and non-carrying metal parts | AC3750V,50/60Hz,1min | |
Vibration resistance | 10-55Hz,1.5mm Double amplitude | |
Shork Resistance | Destruction: OF>0.5N:1000m/s ²(approx.100G)max OF<=0.5N:500m/s ²(approx.50G)max Malfunction: OF>0.5N:300m/s ²(approx.30G)max OF<=0.5N:200m/s ²(approx.20G)max | |
Life Expectancy | Mechnical>=5000000 cycles Electrical>=100000 cycles | |
Degree of protection | IEC IP67 | |
Degree of protection against electric shock | Class I | |
PTI(Tracking Resistance) | 175 | |
Ambient air temperature | 125 Degree 60%RH below(No ice and dew) | |
Ambient air humidity | 85% Rhbelow(about +5~+35 Degree) | |
Weight | Approx.5.95g(No lever) |
1.Degree of Temperature | No Mark:T125 | 5.Terminal Types | A:250 Quick-connect Terminal B:187 Quick-connect terminal(Thick:0.8) C: 187 Quick-connect terminal(Thick:0.5) D:Solder/187 common terminal E:Screw terminal F:Solder terminal G:250 Quick terminal No.2 Y:Not standard terminal |
2.Ratings | 16:16(4)A250VAC/16A125VAC 1/2HP 125/250VAC 10:10(3)A250VAC/10A125VAC 6:6(2)A250VAC/6A125VAC 1:1(1)A250VAC/1A125VAC | ||
6.(max) Operating Force | 100:1N 150:1N 200:2N 250:3N 300:3N 400:4N | ||
3.Connect Forms | Z:SPDT K:SPST-NC B:SPST-NO | ||
7.Plunger specs | No mark:Standard Plunger A: Middle Plunger B: Long Plunger C: Abnormality Plunger Notice:If adopt other not standard plunger,the indicate with the new spec(confirmed by our company) | ||
4.Acuator forms | 0: No lever A 1/1:Short lever A 2/2:Long lever A 3/3:Middle lever A 4/4:Short Roller lever A 5/5:Long Roller lever A 6/6: Arc lever A / :Not standard lever Note: 1) A indicate the lever near to the Plunger,no A indicate the lever far Away from the plunger. 2) If lever is amounted besides,add letter"B" after the lever code. 3) Indicate not standard lever | ||
8.Additional Specis Numbers Apply to: | 1)When used not standard parts such as not standard terminals; 2)When Customer has particular Operating value or other requirement; 3) When the case is mot black, for example, grey shows as G; Additional specs number shows by Arabic numerals or Latin. color code after the numbers. If there is no Additional numbers, the place is vacant |