Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer

China Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer, Find details about China Suction Lift Pump, Gorman-Rupp from Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer

Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Radial Split Casing
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pump, Pumps, Circulating Pump, Chemical Pump
Manufacturer Level
Top Level
Shaft Sealing
Mechanical Seal and Packing
Pump Arrangement
Pipe Hung, Horizontal
Pump Transmission
Direct Coupled, Gear Box, V-Belts, Universal Joint
Flange Standard
Customized
Motor Brand
ABB, Siemens or Reputed Chinese Brands
Pump Bearing
SKF, NSK or Reputed Chinese Brands
Material
Cast Iron
Trademark
Gaofeng
Transport Package
Standard Seaworthy Packing
Specification
Customized
Origin
China
HS Code
8413709990
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Radial Split Casing
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pump, Pumps, Circulating Pump, Chemical Pump
Manufacturer Level
Top Level
Shaft Sealing
Mechanical Seal and Packing
Pump Arrangement
Pipe Hung, Horizontal
Pump Transmission
Direct Coupled, Gear Box, V-Belts, Universal Joint
Flange Standard
Customized
Motor Brand
ABB, Siemens or Reputed Chinese Brands
Pump Bearing
SKF, NSK or Reputed Chinese Brands
Material
Cast Iron
Trademark
Gaofeng
Transport Package
Standard Seaworthy Packing
Specification
Customized
Origin
China
HS Code
8413709990
Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer
Brief introduction:


Our T series non-clogging self-priming centrifugal pump produced by our company has introduced the latest technology and process from the United States. The product has the features of novel structure, reliable performance, unique mechanical seal structure of lubricating oil, no clogging blade and replaceable lining plate.

T series pumps are divided into eight specifications from Φ50 to Φ350, with performance range from flow rate to 1500m3/h and head of 10 to 68m.By cutting the outside diameter of impeller and changing the speed, it can meet various demands of users.

T series self-priming pump is widely used in municipal sewage, industrial waste water treatment engineering and all kinds of waste water classification or centralized treatment system, used for conveying belt slightly corroded or liquid containing a lot of solid particles.



Parameters:
 
Flow rate:Q= 10~1500 (m³/h)
Total head:H=10~68 (m)
Pump speed:n=1450/2900rpm
Design temperature:T=-20~200ºC
Fluid s.g.:γ≤1.85
Pump diameter:50~350mm

Features:

    1. Beautiful appearance, compact structure, reliable performance.
    2. It has a strong self-priming ability, does not need to install the bottom valve.
    3. Non-clogging, non - winding, with a strong ability of debris flow.
    4. Unique lubrication-type mechanical seal cavity structure, seal reliable use.
    5. It has the dismountable drainage hole structure,which ensures the ability to remove debris in time.
    6. Special flap valve structure can make the pump start secondly in time to discharge liquid.
    7. Can be mixed with gas and liquid output in short time.
    8. Low speed, stable operation, long service life, easy maintenance.
    9. Advanced pressure protection device ensures safe operation.



Structure:,

There is a big vortex chamber play important role.It is no need to equip check valve in the inlet and outlet to sewage efficiency when pump operately completely.

Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer
Rotor parts:

Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer
External dimensions:


Model T-8

Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on TrailerStation lift:
Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer

Configuration:
Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on TrailerMovable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer
Application:

a. Municipal project, sewage project, instruction project.

b. Chemical medium with acid or alkali, slurry.Viscosity≤100centipoise,Solid content≤30%.

c. Sewage transportion in hospital, hotel and so on.

d. Classification of municipal sewage treatment factory and concentrate treatment systems engineering.

e. Transportation  of the factory and contaminated water.


Performance:

Model T-8
Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on TrailerMovable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer

Movable Diesel Engine Driven Self-Priming Pump for City Flood Control Drainage Waste Sewage Water  Non-Clogging Mounted on Trailer