т р а н с ф о р м а т о р т о к а 35kv Indoor Type Current Transformer 15 /5A to 2000/5A

China т р а н с ф о р м а т о р т о к а 35kv Indoor Type Current Transformer 15/5A to 2000/5A, Find details about China CT, Current Transformer from т р а н с ф о р м а т о р т о к а 35kv Indoor Type Current Transformer 15/5A to 2000/5A

Model NO.
LZZBJ9-35
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Type of Current Transformer
Indoor Use, Epoxy Resin, Sealed Structure
Rated Voltage
35kv
Applicable Standard
IEC60044-1, IEC61869-2
Combined Accuracy Classes
0.2/10p10, 0.5/10p10
Trademark
DHECN
Transport Package
1PCS/CTN
Specification
15/5A~2000/5A
Origin
China
HS Code
8504311000
Model NO.
LZZBJ9-35
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Type of Current Transformer
Indoor Use, Epoxy Resin, Sealed Structure
Rated Voltage
35kv
Applicable Standard
IEC60044-1, IEC61869-2
Combined Accuracy Classes
0.2/10p10, 0.5/10p10
Trademark
DHECN
Transport Package
1PCS/CTN
Specification
15/5A~2000/5A
Origin
China
HS Code
8504311000
LZZBJ9-35 Type Current Transformer 15/5A~2000/5A
 
Applications
LZZBJ9-35 Current Transformer is suitable for power measurement, current monitoring and relay protection in power system with Rated frequency 50Hz or 60Hz and Rated voltage 35kV.
Applicable Standard: IEC60044-1, GB 1208.
Type Designation
  
Operation Conditions
Installation area: Indoor.
Ambient temperature: Max. temperature 40ºC;Min. temperature -5ºC;Daily average temperature can't exceed 30ºC.
Air conditions: No heavy pollution in air.
Technical Parameter
 
ModelRated primary current
(A)
Combined accuracy classesRated output
(VA)
Rated short-time thermo current
(kA/s)
Rated dynamic stability current
(kA/s)
LZZBJ9-35150.2/10P10
0.5/10P10
0.2/5P20
0.5/5P20
0.2/0.5/10P10
0.2/0.5/5P20
0.2/10P10/5P20
0.5/10P10/5P20
15/20
20/20
15/20
20/20
15/20/20
15/20/20
15/20/20
20/20/20
1.5/13.75
202/15
303/17.5
404/110
505/112.5
757.5/118.75
10010/125
15015/137.5
20020/150
30031.5/180
40031.5/280
50031.5/280
60031.5/280
80031.5/380
100031.5/380
120031.5/380
150031.5/380
200031.5/380
Rated secondary current: 5A or 1A.
Insulation level: 40.5/95/185kV.
 
Structure and Feature
The Type Voltage Transformer is of epoxy resin, hermetically sealed structure with excellent insulative performance and anti-damp capacity. It has outling and easily-cleaned surface. Secondary outlet terminal is equipped with connection terminal box. Upside and profile of the box have a hole respectively. The two holes together with outlet terminal are for leading out. Four holes at the bottom of the PT are suitable for mounting.