Factory Rogowski Coil Current Sensors 333mv or 100mv

China Factory Rogowski Coil Current Sensors 333mv or 100mv, Find details about China Current Transformer, Toroidal Transformer from Factory Rogowski Coil Current Sensors 333mv or 100mv

Model NO.
XH-RST
IP Rating
IP67
Certification
CE
Customized
Customized
Current Transformer
Flexible Rogowski Coil Current Transformer
Current Sensor
Flexible Rogowski Coil Current Sensor
Current Transducer
Flexible Rogowski Coil Current Transducer
Usage
Consumption Sensor
Output
0-0.333V AC or 0-5V AC
Accuracy
1.0
Frequency
50/60Hz
Size
Small
Color
Black
Insulation Strength
3kv
Trademark
Jiangyin spark
Transport Package
Cartons
Specification
ROHS, ISO9001: 2008
Origin
China(Mainland)
HS Code
8504
Model NO.
XH-RST
IP Rating
IP67
Certification
CE
Customized
Customized
Current Transformer
Flexible Rogowski Coil Current Transformer
Current Sensor
Flexible Rogowski Coil Current Sensor
Current Transducer
Flexible Rogowski Coil Current Transducer
Usage
Consumption Sensor
Output
0-0.333V AC or 0-5V AC
Accuracy
1.0
Frequency
50/60Hz
Size
Small
Color
Black
Insulation Strength
3kv
Trademark
Jiangyin spark
Transport Package
Cartons
Specification
ROHS, ISO9001: 2008
Origin
China(Mainland)
HS Code
8504
Specifications Of Factory Rogowski Coil Current Sensors 333mV or 100mV
1.Coil length 0.2m-2m 
2.input current 100A-100KA
3. Output 0-0.333V AC or 0-5V AC or mA or 1A or 4-20mA DC  or 0-5V DC or 0-10V DC 
4.Accuracy 1% 
 


Details Of Factory Rogowski Coil Current Sensors 333mV or 100mV
Capable of accommodating a range of primary conductor sizes.
Characterized by high sensitivity, accuracy, linearity, minimum phase shift.
Suitable for harsh operating environments (temperature, humidity, EMI).
Current Range: 100A to 100kA
Accuracy: < 1%
Phase Shift: < 1 degrees at 50/60Hz (< 0.5 degrees typical) /li>
Linearity: ±0.2% from 10% to 100% of rated primary current
Primary Conductor Position Sensitivity: ± 2% maximum
Influence of External Field: ± 1.5% maximum
Coil Working voltage: 1000VRMS or 1000VDC
Coil Dielectric Surge Withstand: 5kVRMS for 1 minute
Operating temperature: -20ºC to +60ºC
Leads: Shielded cable, or as per customer need

Factory Rogowski Coil Current Sensors 333mv or 100mv
Factory Rogowski Coil Current Sensors 333mv or 100mv
Factory Rogowski Coil Current Sensors 333mv or 100mv


Production Picture Of Factory Rogowski Coil Current Sensors 333mV or 100mV
Factory Rogowski Coil Current Sensors 333mv or 100mv

Factory Rogowski Coil Current Sensors 333mv or 100mv