China Insulation Resistance Tester (Megger 1kV), Find details about China Resistance Measurement, Resistance tester from Insulation Resistance Tester (Megger 1kV)
This device consists of medium and large scale integrated circuits. The output power is large, the short circuit current value is high, the output voltage with multi-level (each model has four voltage levels).
1. Insulation Resistance Test
Item No. | GD2670A | |||
Rated voltage | 100V DC | 250V DC | 500V DC | 1000V DC |
Measuring range | 0.5MW~99.9MW 100MW~500MW | 0.5MW~99.9MW 100MW~999MW 1.0~1.99GW | 1MW~99.9MW 100MW~999MW 1.0~3.99GW | 2MW~99.9MW 100MW~999MW 1.0~10.00GW |
Open circuit voltage | DC100V+10% | DC250V+10% | DC2500V+10% | DC5000V+10% |
Rated test current | 100KW Load 1mA~1.2mA | 250KW Load 1mA~1.2mA | 500KW Load 1mA~1.2mA | 1MW Load 1mA~1.2mA |
Short-circuited circuit | Less than 2.0mA | |||
Accuracy | 100KΩ~100MΩ: ±(3%+5); 100MΩ above: ±(5%+5) |
DC voltage | AC voltage | |
Measuring range | ±30~±1000V | 30~750V (50/60Hz) |
Resolution | 1kV | |
Accuracy | ±(2%+3) | ±(2%+3) |
Display | LCD display, displayed max. Reading of 9999 | |
Low battery alarm | Battery figure (3 grids) | |
Over limit indication | The "OL" mark appears on the insulation resistance range. | |
Range function | Auto | |
Unit display | Display the function and the electric quantity unit symbol. | |
Working conditions | 0°C-0~40°C/RH ≤85% | |
Storage conditions | -20°C~60°C/RH ≤90% | |
Dimension | 202*155*94mm | |
Weight | 2kg (Battery included) | |
Current consumption | Approx. 600mA (Max.) (usually keep in 20mA) |