Insulation Resistance Tester (Megger 1kV)

China Insulation Resistance Tester (Megger 1kV), Find details about China Resistance Measurement, Resistance tester from Insulation Resistance Tester (Megger 1kV)

Model NO.
GD2670A
Accuracy
100KΩ~100MΩ: ±(3%+5);
Accuracy 2
100M&Omega above: ±(5%+5)
DC voltage measuring range
±30~±1000V
AC voltage measuring range
30~750V (50/60Hz)
Voltage accuracy
±(2%+3)
Trademark
HV Hipot
Transport Package
Wooden Box
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
Model NO.
GD2670A
Accuracy
100KΩ~100MΩ: ±(3%+5);
Accuracy 2
100M&Omega above: ±(5%+5)
DC voltage measuring range
±30~±1000V
AC voltage measuring range
30~750V (50/60Hz)
Voltage accuracy
±(2%+3)
Trademark
HV Hipot
Transport Package
Wooden Box
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
Product Description

This device consists of medium and large scale integrated circuits. The output power is large, the short circuit current value is high, the output voltage with multi-level (each model has four voltage levels).


Features
  •  Large output power, high load capacity, strong anti-interference ability.
  • Automatic release voltage function.
  • USB interface data transmission.
  • Backlight function is easy to work in the dark light.
  • Bar chart display measurement results.
  • With high voltage prompt and red warning light.
  • Automatic shutdown function: If user do not operate, it will automatically shut down in 15 minutes after the end of the measurement, press ON/OFF key for 1s to start-up after automatic shutdown.
  • 18 groups of data storage function.
  • Set test time TIME function: automatically perform measurement within 15 minutes of the specified time.
  • COMP measurement (comparative function measurement).
  • PI measurement (polarization index measurement).
    PI measurement can be in any two points, according to the set automatically measuring the resistance ratio.
  • Error limit: ±(a% readings+digits), guarantee period of one year.
  • Environmental temperature: 23±5°C.
  • Environment humidity: 45~75%RH.
Specifications

1. Insulation Resistance Test

Item No.GD2670A
Rated voltage100V DC250V DC500V DC1000V DC
Measuring range0.5MW~99.9MW
100MW~500MW
0.5MW~99.9MW
100MW~999MW
1.0~1.99GW
1MW~99.9MW
100MW~999MW
1.0~3.99GW
2MW~99.9MW
100MW~999MW
1.0~10.00GW
Open circuit voltageDC100V+10%DC250V+10%DC2500V+10%DC5000V+10%
Rated test current100KW Load
1mA~1.2mA
250KW Load
1mA~1.2mA
500KW Load
1mA~1.2mA
1MW Load
1mA~1.2mA
Short-circuited circuit Less than 2.0mA
Accuracy 100KΩ~100MΩ: ±(3%+5); 100MΩ above: ±(5%+5)
Note: at any rated test voltage, when the measured resistance is less than 10MΩ, and no continuous measurement for more than 10 seconds.

2. Voltage Test
 DC voltageAC voltage
Measuring range±30~±1000V30~750V (50/60Hz)
Resolution1kV
Accuracy ±(2%+3)±(2%+3)
Display LCD display, displayed max. Reading of 9999
Low battery alarmBattery figure (3 grids)
Over limit indicationThe "OL" mark appears on the insulation resistance range.
Range functionAuto
Unit displayDisplay the function and the electric quantity unit symbol.
Working conditions0°C-0~40°C/RH ≤85%
Storage conditions-20°C~60°C/RH ≤90%
Dimension202*155*94mm
Weight 2kg (Battery included)
Current consumptionApprox. 600mA (Max.) (usually keep in 20mA)

Insulation Resistance Tester (Megger 1kV)