Turgo Turbine / Turgo Water Turbine / Turgo Turbine Generator Unit

China Turgo Turbine / Turgo Water Turbine / Turgo Turbine Generator Unit, Find details about China Turgo Turbine, Water Turbine from Turgo Turbine / Turgo Water Turbine / Turgo Turbine Generator Unit

Model NO.
XJ
Standard
Standard
Output Power
50kw ~ 2000kw
Water Head
12m~600m
Frequency
50Hz or 60Hz
Trademark
FUCHUN
Transport Package
Wooden Case
Specification
CE/IEC
Origin
China
Model NO.
XJ
Standard
Standard
Output Power
50kw ~ 2000kw
Water Head
12m~600m
Frequency
50Hz or 60Hz
Trademark
FUCHUN
Transport Package
Wooden Case
Specification
CE/IEC
Origin
China
Small Turgo Turbine / Water Turbine For Hydro Power Project 

Turgo turbine compared with tangential impulse or called pelton one has a lot of advantage such as higher specific speed,wide range of application as well as easy match directive driving generator,except wide range of application as well as easy match directive driving generator,except simple of construction, reliable operation,convenience in operation and maintenance etc.
  • output: 50KW~2000KW
  • water head:12m~600m
  • water flow: 0.005 m3/s~2.3m3/s
  • frequency: 50HZ or 60HZ
  • high efficiency
  • operational reliably
  • long service life
  • CE Certificate,Manufacture

Turgo or called inclined-jet impulse turbine is a kind of impulse turbine.Its nozzle make the angle of 22.5°with the rotating plane of the runner.Water come from reservoir or forebay enters the nozzle via a penstock and the intake pipe becomes high velocity jet,then the jet injects the vanes of runner. The water flow enters in the inlet of vane and go out of the vane and the turbine does a work.Its output drives a generator via shaft and a coupling.

Turgo Turbine / Turgo Water Turbine / Turgo Turbine Generator Unit
  


   Company Information


   Our company is an experienced manufacture and engineering Company in small scale hydro power equipment. We play the role of manufacture and EPC contractor and could supply water to wire equipments and services. As turbine manufacture more than 60 years experience.
   We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.

1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply 
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant

8. Hydro power plant spares supply
9.Services
Turgo Turbine / Turgo Water Turbine / Turgo Turbine Generator Unit
      Our factory occupies 560,000 square meters of land, which includes 18 workshops, over 320 sets of heavy and precision producing and testing machinery; scientific research development center in the southern China, and various testing facilities. We have a general technical staff of 380 and 135 senior technical professionals. 
 

Turgo Turbine / Turgo Water Turbine / Turgo Turbine Generator Unit
Reference List of Some Export Projects
No.Country and Power Station Exported toTechnical ParametersTypeQtyDate of contract
1HPP2
 Guatemala
Rated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-80/2×6.5
SFW1000-8/1180
12013.06
2 Pakistan Type:HL855a
Runner diameter:1750mm
27Mw spare runners 12013.06
3UKRated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-55/1×712013.03
4turkeyRated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
12013.05
5Sri LankaRated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-6/1180
12013.05
6CongoRated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9.5
SFW700-8/1180
12013.05
7 
Ecuador
Rated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-6/1430
22012.12
8
Philippines 
Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-160
SF320-36/2150
12012.12
9
 Guatemala
Rated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-80/2×9
SFW614-12/1180
CJA475-W-80/2×6.5
SFW302-12/990
22012.11
10UKRated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1x8.512012.11
11 UKRated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-4212012.11
12UKRated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-5012012.11
13UKRated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-5012012.11
14UKRated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-5012012.11
15 HPP1
 Guatemala 
Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-8/990
22012.8
16UKRated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-40/1×9
SFW100-8/590
12012.04
17EcuadorRated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
12012.04
18Italy Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-40
22012.03
19 Pakistan Type:HL855a
Runner diameter:1750mm
27Mw spare runners 32011.11
20ITALYRated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-10/850
22011.06
21ItalyRated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-85/1×9.5
SFW715-8/1180
32011.05
22 UKRated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-8/590
12011.03
23HPP1
Albania
Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-105/2×7.5
SFW2150-8/1730
12010.12
24 HPP2
Albania
Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-115/2×8
SFW3000-8/1730
12010.12
25 Italy Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-42
HLD74-WJ-60
22010.12
26
Afghanistan 
Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500--6/850
52010.12
27 
Pakistan
Rated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
CJA475-W-100/2×10
SFW1500-10/1430
22010.08
28 HPP1
Vietnam
Rated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV
HL69-LJ-205
SF37500-10/3600
22010.02
29 
Mozambique
Rated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9
SFW570-8/990
12010.04
30
Pakistan 
Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
HLA696-WJ-68
SFW1000-8/1180
32010.03
31 Italy Rated head:35m
Rated flow:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/990
32010.01
32Italy Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kV
CJA475-W-110/2×8.5
SFW1600-10/1730
22009.07
33GeorgiaRated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner change 32009.06
34
Vietnam
Rated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV
HLA883-LJ-155
SF17000-12/3250
22009.01